Cargando…

Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis

BACKGROUND: The aim of this study was to analyze the clinical outcomes of autogenous brachiocephalic arteriovenous fistulas and to investigate the factors associated with 1-year patency after initiation of hemodialysis. METHODS: We retrospectively reviewed the medical records of 41 patients who unde...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jonggeun, Lee, Seogjae, Chang, Jee Won, Kim, Su Wan, Song, Jung-Kook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Thoracic and Cardiovascular Surgery 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7287223/
https://www.ncbi.nlm.nih.gov/pubmed/32551292
http://dx.doi.org/10.5090/kjtcs.2020.53.3.121
_version_ 1783545025585479680
author Lee, Jonggeun
Lee, Seogjae
Chang, Jee Won
Kim, Su Wan
Song, Jung-Kook
author_facet Lee, Jonggeun
Lee, Seogjae
Chang, Jee Won
Kim, Su Wan
Song, Jung-Kook
author_sort Lee, Jonggeun
collection PubMed
description BACKGROUND: The aim of this study was to analyze the clinical outcomes of autogenous brachiocephalic arteriovenous fistulas and to investigate the factors associated with 1-year patency after initiation of hemodialysis. METHODS: We retrospectively reviewed the medical records of 41 patients who underwent surgery to create an autogenous brachiocephalic arteriovenous fistula between January 2015 and December 2017, received hemodialysis at the same hospital for longer than 1 year, and were monitored for their vascular access status. Intraoperative flow was measured using transit-time ultrasonography. RESULTS: The 1-year primary and secondary patency rates were 61% (n=25) and 87.8% (n=36), respectively. The functional group (subjects who required no intervention to maintain patency within the first year after hemodialysis initiation) displayed a significantly higher median intraoperative flow rate (450 mL/min) than the non-functional group (subjects who required intervention at least once regardless of 1-year patency) (275 mL/min) (p=0.038). Based on a receiver operating characteristic curve analysis, all patients were additionally subdivided into a high-flow group (>240 mL/min) and a low-flow group (≤240 mL/min). The high-flow group included a significantly greater number of functional brachiocephalic arteriovenous fistulas than the low-flow group (74.2% vs. 20%, respectively; p=0.007). CONCLUSION: Transit-time flow, as measured with intraoperative transit-time ultrasonography, was associated with patency without the need for intervention at 1 year after initiation of hemodialysis.
format Online
Article
Text
id pubmed-7287223
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Society for Thoracic and Cardiovascular Surgery
record_format MEDLINE/PubMed
spelling pubmed-72872232020-06-17 Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis Lee, Jonggeun Lee, Seogjae Chang, Jee Won Kim, Su Wan Song, Jung-Kook Korean J Thorac Cardiovasc Surg Clinical Research BACKGROUND: The aim of this study was to analyze the clinical outcomes of autogenous brachiocephalic arteriovenous fistulas and to investigate the factors associated with 1-year patency after initiation of hemodialysis. METHODS: We retrospectively reviewed the medical records of 41 patients who underwent surgery to create an autogenous brachiocephalic arteriovenous fistula between January 2015 and December 2017, received hemodialysis at the same hospital for longer than 1 year, and were monitored for their vascular access status. Intraoperative flow was measured using transit-time ultrasonography. RESULTS: The 1-year primary and secondary patency rates were 61% (n=25) and 87.8% (n=36), respectively. The functional group (subjects who required no intervention to maintain patency within the first year after hemodialysis initiation) displayed a significantly higher median intraoperative flow rate (450 mL/min) than the non-functional group (subjects who required intervention at least once regardless of 1-year patency) (275 mL/min) (p=0.038). Based on a receiver operating characteristic curve analysis, all patients were additionally subdivided into a high-flow group (>240 mL/min) and a low-flow group (≤240 mL/min). The high-flow group included a significantly greater number of functional brachiocephalic arteriovenous fistulas than the low-flow group (74.2% vs. 20%, respectively; p=0.007). CONCLUSION: Transit-time flow, as measured with intraoperative transit-time ultrasonography, was associated with patency without the need for intervention at 1 year after initiation of hemodialysis. The Korean Society for Thoracic and Cardiovascular Surgery 2020-06-05 2020-06-05 /pmc/articles/PMC7287223/ /pubmed/32551292 http://dx.doi.org/10.5090/kjtcs.2020.53.3.121 Text en Copyright © The Korean Society for Thoracic and Cardiovascular Surgery. 2020. All right reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research
Lee, Jonggeun
Lee, Seogjae
Chang, Jee Won
Kim, Su Wan
Song, Jung-Kook
Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis
title Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis
title_full Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis
title_fullStr Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis
title_full_unstemmed Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis
title_short Clinical Value of Intraoperative Flow Measurements of Brachiocephalic Arteriovenous Fistulas for Hemodialysis
title_sort clinical value of intraoperative flow measurements of brachiocephalic arteriovenous fistulas for hemodialysis
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7287223/
https://www.ncbi.nlm.nih.gov/pubmed/32551292
http://dx.doi.org/10.5090/kjtcs.2020.53.3.121
work_keys_str_mv AT leejonggeun clinicalvalueofintraoperativeflowmeasurementsofbrachiocephalicarteriovenousfistulasforhemodialysis
AT leeseogjae clinicalvalueofintraoperativeflowmeasurementsofbrachiocephalicarteriovenousfistulasforhemodialysis
AT changjeewon clinicalvalueofintraoperativeflowmeasurementsofbrachiocephalicarteriovenousfistulasforhemodialysis
AT kimsuwan clinicalvalueofintraoperativeflowmeasurementsofbrachiocephalicarteriovenousfistulasforhemodialysis
AT songjungkook clinicalvalueofintraoperativeflowmeasurementsofbrachiocephalicarteriovenousfistulasforhemodialysis