Cargando…

Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm

INTRODUCTION: Acute renal failure is a frequent major complication (24%) of endovascular repair for ruptured abdominal aneurysm (rAAA). Iodinated contrast media is known to be nephrotoxic. This report describes a case of endovascular aneurysm repair (EVAR) under fusion imaging guidance in a patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Masana Llimona, Marc, Altés Mas, Pere, Martínez Carnovale, Lucía, Llagostera Pujol, Secundino
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7287378/
https://www.ncbi.nlm.nih.gov/pubmed/33078150
http://dx.doi.org/10.1016/j.ejvsvf.2020.03.001
_version_ 1783545051247280128
author Masana Llimona, Marc
Altés Mas, Pere
Martínez Carnovale, Lucía
Llagostera Pujol, Secundino
author_facet Masana Llimona, Marc
Altés Mas, Pere
Martínez Carnovale, Lucía
Llagostera Pujol, Secundino
author_sort Masana Llimona, Marc
collection PubMed
description INTRODUCTION: Acute renal failure is a frequent major complication (24%) of endovascular repair for ruptured abdominal aneurysm (rAAA). Iodinated contrast media is known to be nephrotoxic. This report describes a case of endovascular aneurysm repair (EVAR) under fusion imaging guidance in a patient diagnosed with a rAAA after non-contrast CT. Written consent was obtained from the patient. REPORT: A 73 year old patient with stage IV chronic kidney failure and contrast-induced nephropathy was diagnosed with rAAA using non-contrast CT. Subsequently, the patient was treated with EVAR using fusion imaging. DISCUSSION: EVAR with fusion imaging after non-contrast CT was safe in a patient with rAAA. It could represent an option for patients with acute renal failure in emergency settings.
format Online
Article
Text
id pubmed-7287378
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-72873782020-06-12 Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm Masana Llimona, Marc Altés Mas, Pere Martínez Carnovale, Lucía Llagostera Pujol, Secundino EJVES Vasc Forum Case Report INTRODUCTION: Acute renal failure is a frequent major complication (24%) of endovascular repair for ruptured abdominal aneurysm (rAAA). Iodinated contrast media is known to be nephrotoxic. This report describes a case of endovascular aneurysm repair (EVAR) under fusion imaging guidance in a patient diagnosed with a rAAA after non-contrast CT. Written consent was obtained from the patient. REPORT: A 73 year old patient with stage IV chronic kidney failure and contrast-induced nephropathy was diagnosed with rAAA using non-contrast CT. Subsequently, the patient was treated with EVAR using fusion imaging. DISCUSSION: EVAR with fusion imaging after non-contrast CT was safe in a patient with rAAA. It could represent an option for patients with acute renal failure in emergency settings. Elsevier 2020-03-26 /pmc/articles/PMC7287378/ /pubmed/33078150 http://dx.doi.org/10.1016/j.ejvsvf.2020.03.001 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Masana Llimona, Marc
Altés Mas, Pere
Martínez Carnovale, Lucía
Llagostera Pujol, Secundino
Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm
title Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm
title_full Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm
title_fullStr Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm
title_full_unstemmed Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm
title_short Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm
title_sort feasibility of intraoperative fusion imaging using non-contrast ct scan for evar in ruptured abdominal aortic aneurysm
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7287378/
https://www.ncbi.nlm.nih.gov/pubmed/33078150
http://dx.doi.org/10.1016/j.ejvsvf.2020.03.001
work_keys_str_mv AT masanallimonamarc feasibilityofintraoperativefusionimagingusingnoncontrastctscanforevarinrupturedabdominalaorticaneurysm
AT altesmaspere feasibilityofintraoperativefusionimagingusingnoncontrastctscanforevarinrupturedabdominalaorticaneurysm
AT martinezcarnovalelucia feasibilityofintraoperativefusionimagingusingnoncontrastctscanforevarinrupturedabdominalaorticaneurysm
AT llagosterapujolsecundino feasibilityofintraoperativefusionimagingusingnoncontrastctscanforevarinrupturedabdominalaorticaneurysm