Cargando…
Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform
An electrochemical enzyme-linked immunosorbent assay (ELISA) biosensor platform using electrochemically prepared ~11 nm thick carboxylic functionalized popypyrrole film has been developed for bio-analyte measurement in undiluted serum. Carboxyl polypyrrole (PPy-COOH) film using 3-carboxy-pyrrol mono...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7287672/ https://www.ncbi.nlm.nih.gov/pubmed/32443483 http://dx.doi.org/10.3390/s20102857 |
_version_ | 1783545102528937984 |
---|---|
author | Arya, Sunil K. Estrela, Pedro |
author_facet | Arya, Sunil K. Estrela, Pedro |
author_sort | Arya, Sunil K. |
collection | PubMed |
description | An electrochemical enzyme-linked immunosorbent assay (ELISA) biosensor platform using electrochemically prepared ~11 nm thick carboxylic functionalized popypyrrole film has been developed for bio-analyte measurement in undiluted serum. Carboxyl polypyrrole (PPy-COOH) film using 3-carboxy-pyrrol monomer onto comb-shaped gold electrode microarray (Au) was prepared via cyclic voltammetry (CV). The prepared Au/PPy-COOH was then utilized for electrochemical ELISA platform development by immobilizing analyte-specific antibodies. Tumor necrosis factor-alpha (TNF-α) was selected as a model analyte and detected in undiluted serum. For enhanced performance, the use of a polymeric alkaline phosphatase tag was investigated for the electrochemical ELISA. The developed platform was characterized at each step of fabrication using CV, electrochemical impedance spectroscopy and atomic force microscopy. The bioelectrodes exhibited linearity for TNF-α in the 100 pg/mL–100 ng/mL range when measured in spiked serum, with limit of detection of 78 pg/mL. The sensor showed insignificant signal disturbance from serum proteins and other biologically important proteins. The developed platform was found to be fast and specific and can be applicable for testing and measuring various biologically important protein markers in real samples. |
format | Online Article Text |
id | pubmed-7287672 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72876722020-06-15 Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform Arya, Sunil K. Estrela, Pedro Sensors (Basel) Letter An electrochemical enzyme-linked immunosorbent assay (ELISA) biosensor platform using electrochemically prepared ~11 nm thick carboxylic functionalized popypyrrole film has been developed for bio-analyte measurement in undiluted serum. Carboxyl polypyrrole (PPy-COOH) film using 3-carboxy-pyrrol monomer onto comb-shaped gold electrode microarray (Au) was prepared via cyclic voltammetry (CV). The prepared Au/PPy-COOH was then utilized for electrochemical ELISA platform development by immobilizing analyte-specific antibodies. Tumor necrosis factor-alpha (TNF-α) was selected as a model analyte and detected in undiluted serum. For enhanced performance, the use of a polymeric alkaline phosphatase tag was investigated for the electrochemical ELISA. The developed platform was characterized at each step of fabrication using CV, electrochemical impedance spectroscopy and atomic force microscopy. The bioelectrodes exhibited linearity for TNF-α in the 100 pg/mL–100 ng/mL range when measured in spiked serum, with limit of detection of 78 pg/mL. The sensor showed insignificant signal disturbance from serum proteins and other biologically important proteins. The developed platform was found to be fast and specific and can be applicable for testing and measuring various biologically important protein markers in real samples. MDPI 2020-05-18 /pmc/articles/PMC7287672/ /pubmed/32443483 http://dx.doi.org/10.3390/s20102857 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Letter Arya, Sunil K. Estrela, Pedro Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform |
title | Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform |
title_full | Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform |
title_fullStr | Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform |
title_full_unstemmed | Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform |
title_short | Electrochemical ELISA Protein Biosensing in Undiluted Serum Using a Polypyrrole-Based Platform |
title_sort | electrochemical elisa protein biosensing in undiluted serum using a polypyrrole-based platform |
topic | Letter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7287672/ https://www.ncbi.nlm.nih.gov/pubmed/32443483 http://dx.doi.org/10.3390/s20102857 |
work_keys_str_mv | AT aryasunilk electrochemicalelisaproteinbiosensinginundilutedserumusingapolypyrrolebasedplatform AT estrelapedro electrochemicalelisaproteinbiosensinginundilutedserumusingapolypyrrolebasedplatform |