Cargando…
Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises
This work proposes to improve the accuracy of joint angle estimates obtained from an RGB-D sensor. It is based on a constrained extended Kalman Filter that tracks inputted measured joint centers. Since the proposed approach uses a biomechanical model, it allows physically consistent constrained join...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7288061/ https://www.ncbi.nlm.nih.gov/pubmed/32429505 http://dx.doi.org/10.3390/s20102848 |
_version_ | 1783545192969666560 |
---|---|
author | Colombel, Jessica Bonnet, Vincent Daney, David Dumas, Raphael Seilles, Antoine Charpillet, François |
author_facet | Colombel, Jessica Bonnet, Vincent Daney, David Dumas, Raphael Seilles, Antoine Charpillet, François |
author_sort | Colombel, Jessica |
collection | PubMed |
description | This work proposes to improve the accuracy of joint angle estimates obtained from an RGB-D sensor. It is based on a constrained extended Kalman Filter that tracks inputted measured joint centers. Since the proposed approach uses a biomechanical model, it allows physically consistent constrained joint angles and constant segment lengths to be obtained. A practical method that is not sensor-specific for the optimal tuning of the extended Kalman filter covariance matrices is provided. It uses reference data obtained from a stereophotogrammetric system but it has to be tuned only once since it is task-specific only. The improvement of the optimal tuning over classical methods in setting the covariance matrices is shown with a statistical parametric mapping analysis. The proposed approach was tested with six healthy subjects who performed four rehabilitation tasks. The accuracy of joint angle estimates was assessed with a reference stereophotogrammetric system. Even if some joint angles, such as the internal/external rotations, were not well estimated, the proposed optimized algorithm reached a satisfactory average root mean square difference of 9.7 [Formula: see text] and a correlation coefficient of 0.8 for all joints. Our results show that an affordable RGB-D sensor can be used for simple in-home rehabilitation when using a constrained biomechanical model. |
format | Online Article Text |
id | pubmed-7288061 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72880612020-06-15 Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises Colombel, Jessica Bonnet, Vincent Daney, David Dumas, Raphael Seilles, Antoine Charpillet, François Sensors (Basel) Article This work proposes to improve the accuracy of joint angle estimates obtained from an RGB-D sensor. It is based on a constrained extended Kalman Filter that tracks inputted measured joint centers. Since the proposed approach uses a biomechanical model, it allows physically consistent constrained joint angles and constant segment lengths to be obtained. A practical method that is not sensor-specific for the optimal tuning of the extended Kalman filter covariance matrices is provided. It uses reference data obtained from a stereophotogrammetric system but it has to be tuned only once since it is task-specific only. The improvement of the optimal tuning over classical methods in setting the covariance matrices is shown with a statistical parametric mapping analysis. The proposed approach was tested with six healthy subjects who performed four rehabilitation tasks. The accuracy of joint angle estimates was assessed with a reference stereophotogrammetric system. Even if some joint angles, such as the internal/external rotations, were not well estimated, the proposed optimized algorithm reached a satisfactory average root mean square difference of 9.7 [Formula: see text] and a correlation coefficient of 0.8 for all joints. Our results show that an affordable RGB-D sensor can be used for simple in-home rehabilitation when using a constrained biomechanical model. MDPI 2020-05-17 /pmc/articles/PMC7288061/ /pubmed/32429505 http://dx.doi.org/10.3390/s20102848 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Colombel, Jessica Bonnet, Vincent Daney, David Dumas, Raphael Seilles, Antoine Charpillet, François Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises |
title | Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises |
title_full | Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises |
title_fullStr | Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises |
title_full_unstemmed | Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises |
title_short | Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises |
title_sort | physically consistent whole-body kinematics assessment based on an rgb-d sensor. application to simple rehabilitation exercises |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7288061/ https://www.ncbi.nlm.nih.gov/pubmed/32429505 http://dx.doi.org/10.3390/s20102848 |
work_keys_str_mv | AT colombeljessica physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises AT bonnetvincent physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises AT daneydavid physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises AT dumasraphael physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises AT seillesantoine physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises AT charpilletfrancois physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises |