Cargando…

Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises

This work proposes to improve the accuracy of joint angle estimates obtained from an RGB-D sensor. It is based on a constrained extended Kalman Filter that tracks inputted measured joint centers. Since the proposed approach uses a biomechanical model, it allows physically consistent constrained join...

Descripción completa

Detalles Bibliográficos
Autores principales: Colombel, Jessica, Bonnet, Vincent, Daney, David, Dumas, Raphael, Seilles, Antoine, Charpillet, François
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7288061/
https://www.ncbi.nlm.nih.gov/pubmed/32429505
http://dx.doi.org/10.3390/s20102848
_version_ 1783545192969666560
author Colombel, Jessica
Bonnet, Vincent
Daney, David
Dumas, Raphael
Seilles, Antoine
Charpillet, François
author_facet Colombel, Jessica
Bonnet, Vincent
Daney, David
Dumas, Raphael
Seilles, Antoine
Charpillet, François
author_sort Colombel, Jessica
collection PubMed
description This work proposes to improve the accuracy of joint angle estimates obtained from an RGB-D sensor. It is based on a constrained extended Kalman Filter that tracks inputted measured joint centers. Since the proposed approach uses a biomechanical model, it allows physically consistent constrained joint angles and constant segment lengths to be obtained. A practical method that is not sensor-specific for the optimal tuning of the extended Kalman filter covariance matrices is provided. It uses reference data obtained from a stereophotogrammetric system but it has to be tuned only once since it is task-specific only. The improvement of the optimal tuning over classical methods in setting the covariance matrices is shown with a statistical parametric mapping analysis. The proposed approach was tested with six healthy subjects who performed four rehabilitation tasks. The accuracy of joint angle estimates was assessed with a reference stereophotogrammetric system. Even if some joint angles, such as the internal/external rotations, were not well estimated, the proposed optimized algorithm reached a satisfactory average root mean square difference of 9.7 [Formula: see text] and a correlation coefficient of 0.8 for all joints. Our results show that an affordable RGB-D sensor can be used for simple in-home rehabilitation when using a constrained biomechanical model.
format Online
Article
Text
id pubmed-7288061
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72880612020-06-15 Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises Colombel, Jessica Bonnet, Vincent Daney, David Dumas, Raphael Seilles, Antoine Charpillet, François Sensors (Basel) Article This work proposes to improve the accuracy of joint angle estimates obtained from an RGB-D sensor. It is based on a constrained extended Kalman Filter that tracks inputted measured joint centers. Since the proposed approach uses a biomechanical model, it allows physically consistent constrained joint angles and constant segment lengths to be obtained. A practical method that is not sensor-specific for the optimal tuning of the extended Kalman filter covariance matrices is provided. It uses reference data obtained from a stereophotogrammetric system but it has to be tuned only once since it is task-specific only. The improvement of the optimal tuning over classical methods in setting the covariance matrices is shown with a statistical parametric mapping analysis. The proposed approach was tested with six healthy subjects who performed four rehabilitation tasks. The accuracy of joint angle estimates was assessed with a reference stereophotogrammetric system. Even if some joint angles, such as the internal/external rotations, were not well estimated, the proposed optimized algorithm reached a satisfactory average root mean square difference of 9.7 [Formula: see text] and a correlation coefficient of 0.8 for all joints. Our results show that an affordable RGB-D sensor can be used for simple in-home rehabilitation when using a constrained biomechanical model. MDPI 2020-05-17 /pmc/articles/PMC7288061/ /pubmed/32429505 http://dx.doi.org/10.3390/s20102848 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Colombel, Jessica
Bonnet, Vincent
Daney, David
Dumas, Raphael
Seilles, Antoine
Charpillet, François
Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises
title Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises
title_full Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises
title_fullStr Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises
title_full_unstemmed Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises
title_short Physically Consistent Whole-Body Kinematics Assessment Based on an RGB-D Sensor. Application to Simple Rehabilitation Exercises
title_sort physically consistent whole-body kinematics assessment based on an rgb-d sensor. application to simple rehabilitation exercises
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7288061/
https://www.ncbi.nlm.nih.gov/pubmed/32429505
http://dx.doi.org/10.3390/s20102848
work_keys_str_mv AT colombeljessica physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises
AT bonnetvincent physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises
AT daneydavid physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises
AT dumasraphael physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises
AT seillesantoine physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises
AT charpilletfrancois physicallyconsistentwholebodykinematicsassessmentbasedonanrgbdsensorapplicationtosimplerehabilitationexercises