Cargando…
Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia
The Loopamp™ MTBC kit (TB-LAMP) is recommended by WHO for Mycobacterium tuberculosis complex detection in low-income countries with a still low drug-resistant tuberculosis (TB) rate. This study is aimed at testing its feasibility in Cambodia on sputa collected from presumptive tuberculosis patients....
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7288195/ https://www.ncbi.nlm.nih.gov/pubmed/32596349 http://dx.doi.org/10.1155/2020/6828043 |
_version_ | 1783545224761442304 |
---|---|
author | Cheng, Sokleaph Pheng, Sok Heng Heng, Seiha Marks, Guy B. Bañuls, Anne-Laure Mao, Tan Eang Kerléguer, Alexandra |
author_facet | Cheng, Sokleaph Pheng, Sok Heng Heng, Seiha Marks, Guy B. Bañuls, Anne-Laure Mao, Tan Eang Kerléguer, Alexandra |
author_sort | Cheng, Sokleaph |
collection | PubMed |
description | The Loopamp™ MTBC kit (TB-LAMP) is recommended by WHO for Mycobacterium tuberculosis complex detection in low-income countries with a still low drug-resistant tuberculosis (TB) rate. This study is aimed at testing its feasibility in Cambodia on sputa collected from presumptive tuberculosis patients. 499 samples were tested at a smear microscopy center and 200 at a central-level mycobacteriology laboratory. Using mycobacterial cultures as reference, TB-LAMP results were compared with those of LED fluorescent microscopy (LED-FM) and Xpert® MTB/RIF. At the microscopy center, TB-LAMP sensitivity was higher than that of LED-FM (81.5% [95% CI, 74.5-87.6] versus 69.4% [95% CI, 62.2-76.6]), but lower than that of the Xpert assay (95.5% [95% CI 92.3-98.8]). At the central-level laboratory, TB-LAMP sensitivity (92.8% [95% CI, 87.6-97.9]) was comparable to that of Xpert (90.7% [95% CI, 85.0-96.5]) using stored sample. No significant difference in terms of specificity between TB-LAMP and Xpert assays was observed in both study sites. In conclusion, our data demonstrate that TB-LAMP could be implemented at microscopy centers in Cambodia to detect TB patients. In addition, TB-LAMP can be a better choice to replace smear microscopy for rapid TB diagnosis of new presumptive TB patients, in settings with relative low prevalence of drug-resistant TB and difficulties to implement Xpert assay. |
format | Online Article Text |
id | pubmed-7288195 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-72881952020-06-26 Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia Cheng, Sokleaph Pheng, Sok Heng Heng, Seiha Marks, Guy B. Bañuls, Anne-Laure Mao, Tan Eang Kerléguer, Alexandra Biomed Res Int Research Article The Loopamp™ MTBC kit (TB-LAMP) is recommended by WHO for Mycobacterium tuberculosis complex detection in low-income countries with a still low drug-resistant tuberculosis (TB) rate. This study is aimed at testing its feasibility in Cambodia on sputa collected from presumptive tuberculosis patients. 499 samples were tested at a smear microscopy center and 200 at a central-level mycobacteriology laboratory. Using mycobacterial cultures as reference, TB-LAMP results were compared with those of LED fluorescent microscopy (LED-FM) and Xpert® MTB/RIF. At the microscopy center, TB-LAMP sensitivity was higher than that of LED-FM (81.5% [95% CI, 74.5-87.6] versus 69.4% [95% CI, 62.2-76.6]), but lower than that of the Xpert assay (95.5% [95% CI 92.3-98.8]). At the central-level laboratory, TB-LAMP sensitivity (92.8% [95% CI, 87.6-97.9]) was comparable to that of Xpert (90.7% [95% CI, 85.0-96.5]) using stored sample. No significant difference in terms of specificity between TB-LAMP and Xpert assays was observed in both study sites. In conclusion, our data demonstrate that TB-LAMP could be implemented at microscopy centers in Cambodia to detect TB patients. In addition, TB-LAMP can be a better choice to replace smear microscopy for rapid TB diagnosis of new presumptive TB patients, in settings with relative low prevalence of drug-resistant TB and difficulties to implement Xpert assay. Hindawi 2020-06-01 /pmc/articles/PMC7288195/ /pubmed/32596349 http://dx.doi.org/10.1155/2020/6828043 Text en Copyright © 2020 Sokleaph Cheng et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Cheng, Sokleaph Pheng, Sok Heng Heng, Seiha Marks, Guy B. Bañuls, Anne-Laure Mao, Tan Eang Kerléguer, Alexandra Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia |
title | Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia |
title_full | Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia |
title_fullStr | Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia |
title_full_unstemmed | Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia |
title_short | Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia |
title_sort | evaluation of loopamp assay for the diagnosis of pulmonary tuberculosis in cambodia |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7288195/ https://www.ncbi.nlm.nih.gov/pubmed/32596349 http://dx.doi.org/10.1155/2020/6828043 |
work_keys_str_mv | AT chengsokleaph evaluationofloopampassayforthediagnosisofpulmonarytuberculosisincambodia AT phengsokheng evaluationofloopampassayforthediagnosisofpulmonarytuberculosisincambodia AT hengseiha evaluationofloopampassayforthediagnosisofpulmonarytuberculosisincambodia AT marksguyb evaluationofloopampassayforthediagnosisofpulmonarytuberculosisincambodia AT banulsannelaure evaluationofloopampassayforthediagnosisofpulmonarytuberculosisincambodia AT maotaneang evaluationofloopampassayforthediagnosisofpulmonarytuberculosisincambodia AT kerlegueralexandra evaluationofloopampassayforthediagnosisofpulmonarytuberculosisincambodia |