Cargando…

Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever

There is a critical need for an improved rapid diagnostic for enteric fever. We have previously demonstrated that serum IgA responses targeting Salmonella enterica serovar Typhi hemolysin E (HlyE) and lipopolysaccharide (LPS) are able to discriminate patients with acute typhoid from healthy controls...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumar, Shailendra, Nodoushani, Ariana, Khanam, Farhana, DeCruz, Alyssa T., Lambotte, Paul, Scott, Robert, Bogoch, Isaac I., Vaidya, Krista, Calderwood, Stephen B., Bhuiyan, Taufiqur R., Esfandiari, Javan, Ryan, Edward T., Qadri, Firdausi, Andrews, Jason R., Charles, Richelle C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7289704/
https://www.ncbi.nlm.nih.gov/pubmed/32522777
http://dx.doi.org/10.1128/mSphere.00253-20
_version_ 1783545510521470976
author Kumar, Shailendra
Nodoushani, Ariana
Khanam, Farhana
DeCruz, Alyssa T.
Lambotte, Paul
Scott, Robert
Bogoch, Isaac I.
Vaidya, Krista
Calderwood, Stephen B.
Bhuiyan, Taufiqur R.
Esfandiari, Javan
Ryan, Edward T.
Qadri, Firdausi
Andrews, Jason R.
Charles, Richelle C.
author_facet Kumar, Shailendra
Nodoushani, Ariana
Khanam, Farhana
DeCruz, Alyssa T.
Lambotte, Paul
Scott, Robert
Bogoch, Isaac I.
Vaidya, Krista
Calderwood, Stephen B.
Bhuiyan, Taufiqur R.
Esfandiari, Javan
Ryan, Edward T.
Qadri, Firdausi
Andrews, Jason R.
Charles, Richelle C.
author_sort Kumar, Shailendra
collection PubMed
description There is a critical need for an improved rapid diagnostic for enteric fever. We have previously demonstrated that serum IgA responses targeting Salmonella enterica serovar Typhi hemolysin E (HlyE) and lipopolysaccharide (LPS) are able to discriminate patients with acute typhoid from healthy controls in areas where enteric fever is endemic (healthy endemic controls) and from patients with other bacterial infections. We now have data demonstrating that IgA antibody responses against these antigens also work well for identifying patients with acute S. Paratyphi A infection. To develop a test for acute enteric fever detection, we have adapted a point-of-care immunochromatographic dual-path platform technology (DPP), which improves on the traditional lateral flow technology by using separate sample and conjugate paths and a compact, portable reader, resulting in diagnostics with higher sensitivity and multiplexing abilities. In this analysis, we have compared our standard enzyme-linked immunosorbent assay (ELISA) method to the DPP method in detecting acute phase plasma/serum anti-HlyE and anti-LPS IgA antibodies in a cohort of patients with culture-confirmed S. Typhi (n = 30) and Paratyphi A infection (n = 20), healthy endemic controls (n = 25), and febrile endemic controls (n = 25). We found that the DPP measurements highly correlated with ELISA results, and both antigens had an area under the curve (AUC) of 0.98 (sensitivity of 92%, specificity of 94%) with all controls and an AUC of 0.98 (sensitivity of 90%, specificity of 96%) with febrile endemic controls. Our results suggest that the point-of-care DPP Typhoid System has high diagnostic accuracy for the rapid detection of enteric fever and warrants further evaluation. IMPORTANCE Enteric fever remains a significant global problem, and control programs are significantly limited by the lack of an optimal assay for identifying individuals with acute infection. This is especially critical considering the recently released World Health Organization (WHO) position paper endorsing the role of the typhoid conjugate vaccine in communities where enteric fever is endemic. A reliable diagnostic test is needed to assess and evaluate typhoid intervention strategies and determine which high-burden areas may benefit most from a vaccine intervention. Our collaborative team has developed and evaluated a point-of-care serodiagnostic assay based on detection of anti-HlyE and LPS IgA. Our finding of the high diagnostic accuracy of the DPP Typhoid System for the rapid detection of enteric fever has the potential to have significant public health impact by allowing for improved surveillance and for control and prevention programs in areas with limited laboratory capacity.
format Online
Article
Text
id pubmed-7289704
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-72897042020-06-25 Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever Kumar, Shailendra Nodoushani, Ariana Khanam, Farhana DeCruz, Alyssa T. Lambotte, Paul Scott, Robert Bogoch, Isaac I. Vaidya, Krista Calderwood, Stephen B. Bhuiyan, Taufiqur R. Esfandiari, Javan Ryan, Edward T. Qadri, Firdausi Andrews, Jason R. Charles, Richelle C. mSphere Research Article There is a critical need for an improved rapid diagnostic for enteric fever. We have previously demonstrated that serum IgA responses targeting Salmonella enterica serovar Typhi hemolysin E (HlyE) and lipopolysaccharide (LPS) are able to discriminate patients with acute typhoid from healthy controls in areas where enteric fever is endemic (healthy endemic controls) and from patients with other bacterial infections. We now have data demonstrating that IgA antibody responses against these antigens also work well for identifying patients with acute S. Paratyphi A infection. To develop a test for acute enteric fever detection, we have adapted a point-of-care immunochromatographic dual-path platform technology (DPP), which improves on the traditional lateral flow technology by using separate sample and conjugate paths and a compact, portable reader, resulting in diagnostics with higher sensitivity and multiplexing abilities. In this analysis, we have compared our standard enzyme-linked immunosorbent assay (ELISA) method to the DPP method in detecting acute phase plasma/serum anti-HlyE and anti-LPS IgA antibodies in a cohort of patients with culture-confirmed S. Typhi (n = 30) and Paratyphi A infection (n = 20), healthy endemic controls (n = 25), and febrile endemic controls (n = 25). We found that the DPP measurements highly correlated with ELISA results, and both antigens had an area under the curve (AUC) of 0.98 (sensitivity of 92%, specificity of 94%) with all controls and an AUC of 0.98 (sensitivity of 90%, specificity of 96%) with febrile endemic controls. Our results suggest that the point-of-care DPP Typhoid System has high diagnostic accuracy for the rapid detection of enteric fever and warrants further evaluation. IMPORTANCE Enteric fever remains a significant global problem, and control programs are significantly limited by the lack of an optimal assay for identifying individuals with acute infection. This is especially critical considering the recently released World Health Organization (WHO) position paper endorsing the role of the typhoid conjugate vaccine in communities where enteric fever is endemic. A reliable diagnostic test is needed to assess and evaluate typhoid intervention strategies and determine which high-burden areas may benefit most from a vaccine intervention. Our collaborative team has developed and evaluated a point-of-care serodiagnostic assay based on detection of anti-HlyE and LPS IgA. Our finding of the high diagnostic accuracy of the DPP Typhoid System for the rapid detection of enteric fever has the potential to have significant public health impact by allowing for improved surveillance and for control and prevention programs in areas with limited laboratory capacity. American Society for Microbiology 2020-06-10 /pmc/articles/PMC7289704/ /pubmed/32522777 http://dx.doi.org/10.1128/mSphere.00253-20 Text en Copyright © 2020 Kumar et al. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Kumar, Shailendra
Nodoushani, Ariana
Khanam, Farhana
DeCruz, Alyssa T.
Lambotte, Paul
Scott, Robert
Bogoch, Isaac I.
Vaidya, Krista
Calderwood, Stephen B.
Bhuiyan, Taufiqur R.
Esfandiari, Javan
Ryan, Edward T.
Qadri, Firdausi
Andrews, Jason R.
Charles, Richelle C.
Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever
title Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever
title_full Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever
title_fullStr Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever
title_full_unstemmed Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever
title_short Evaluation of a Rapid Point-of-Care Multiplex Immunochromatographic Assay for the Diagnosis of Enteric Fever
title_sort evaluation of a rapid point-of-care multiplex immunochromatographic assay for the diagnosis of enteric fever
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7289704/
https://www.ncbi.nlm.nih.gov/pubmed/32522777
http://dx.doi.org/10.1128/mSphere.00253-20
work_keys_str_mv AT kumarshailendra evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT nodoushaniariana evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT khanamfarhana evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT decruzalyssat evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT lambottepaul evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT scottrobert evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT bogochisaaci evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT vaidyakrista evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT calderwoodstephenb evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT bhuiyantaufiqurr evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT esfandiarijavan evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT ryanedwardt evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT qadrifirdausi evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT andrewsjasonr evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever
AT charlesrichellec evaluationofarapidpointofcaremultipleximmunochromatographicassayforthediagnosisofentericfever