Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs
Intramedullary nails constitute a viable alternative to extramedullary fixation devices; their use is growing in recent years, especially with reference to self-locking nails. Different designs are available, and it is not trivial to foresee the respective in vivo performances and to provide clinica...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7289914/ https://www.ncbi.nlm.nih.gov/pubmed/32582675 http://dx.doi.org/10.3389/fbioe.2020.00557 |
_version_ | 1783545558506405888 |
---|---|
author | Putame, Giovanni Pascoletti, Giulia Terzini, Mara Zanetti, Elisabetta M. Audenino, Alberto L. |
author_facet | Putame, Giovanni Pascoletti, Giulia Terzini, Mara Zanetti, Elisabetta M. Audenino, Alberto L. |
author_sort | Putame, Giovanni |
collection | PubMed |
description | Intramedullary nails constitute a viable alternative to extramedullary fixation devices; their use is growing in recent years, especially with reference to self-locking nails. Different designs are available, and it is not trivial to foresee the respective in vivo performances and to provide clinical indications in relation to the type of bone and fracture. In this work a numerical methodology was set up and validated in order to compare the mechanical behavior of two new nailing device concepts with one already used in clinic. In detail, three different nails were studied: (1) the Marchetti-Vicenzi's nail (MV(1)), (2) a revised concept of this device (MV(2)), and (3) a new Terzini-Putame's nail (TP) concept. Firstly, the mechanical behavior of the MV(1) device was assessed through experimental loading tests employing a 3D-printed component aimed at reproducing the bone geometry inside which the device is implanted. In the next step, the respective numerical model was created, based on a multibody approach including flexible parts, and this model was validated against the previously obtained experimental results. Finally, numerical models of the MV(2) and TP concepts were implemented and compared with the MV(1) nail, focusing the attention on the response of all devices to compression, tension, bending, and torsion. A stability index (SI) was defined to quantify the mechanical stability provided to the nail-bone assembly by the elastic self-locking mechanism for the various loading conditions. In addition, results in terms of nail-bone assembly stiffness, computed from force/moment vs. displacement/rotation curves, were presented and discussed. Findings revealed that numerical models were able to provide good estimates of load vs. displacement curves. The TP nail concept proved to be able to generate a significantly higher SI (27 N for MV(1) vs. 380 N for TP) and a greater stiffening action (up to a stiffness difference for bending load that ranges from 370 Nmm/° for MV(1) to 1,532 Nmm/° for TP) than the other two devices which showed similar performances. On the whole, a demonstration was given of information which can be obtained from numerical simulations of expandable fixation devices. |
format | Online Article Text |
id | pubmed-7289914 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-72899142020-06-23 Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs Putame, Giovanni Pascoletti, Giulia Terzini, Mara Zanetti, Elisabetta M. Audenino, Alberto L. Front Bioeng Biotechnol Bioengineering and Biotechnology Intramedullary nails constitute a viable alternative to extramedullary fixation devices; their use is growing in recent years, especially with reference to self-locking nails. Different designs are available, and it is not trivial to foresee the respective in vivo performances and to provide clinical indications in relation to the type of bone and fracture. In this work a numerical methodology was set up and validated in order to compare the mechanical behavior of two new nailing device concepts with one already used in clinic. In detail, three different nails were studied: (1) the Marchetti-Vicenzi's nail (MV(1)), (2) a revised concept of this device (MV(2)), and (3) a new Terzini-Putame's nail (TP) concept. Firstly, the mechanical behavior of the MV(1) device was assessed through experimental loading tests employing a 3D-printed component aimed at reproducing the bone geometry inside which the device is implanted. In the next step, the respective numerical model was created, based on a multibody approach including flexible parts, and this model was validated against the previously obtained experimental results. Finally, numerical models of the MV(2) and TP concepts were implemented and compared with the MV(1) nail, focusing the attention on the response of all devices to compression, tension, bending, and torsion. A stability index (SI) was defined to quantify the mechanical stability provided to the nail-bone assembly by the elastic self-locking mechanism for the various loading conditions. In addition, results in terms of nail-bone assembly stiffness, computed from force/moment vs. displacement/rotation curves, were presented and discussed. Findings revealed that numerical models were able to provide good estimates of load vs. displacement curves. The TP nail concept proved to be able to generate a significantly higher SI (27 N for MV(1) vs. 380 N for TP) and a greater stiffening action (up to a stiffness difference for bending load that ranges from 370 Nmm/° for MV(1) to 1,532 Nmm/° for TP) than the other two devices which showed similar performances. On the whole, a demonstration was given of information which can be obtained from numerical simulations of expandable fixation devices. Frontiers Media S.A. 2020-06-05 /pmc/articles/PMC7289914/ /pubmed/32582675 http://dx.doi.org/10.3389/fbioe.2020.00557 Text en Copyright © 2020 Putame, Pascoletti, Terzini, Zanetti and Audenino. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Putame, Giovanni Pascoletti, Giulia Terzini, Mara Zanetti, Elisabetta M. Audenino, Alberto L. Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs |
title | Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs |
title_full | Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs |
title_fullStr | Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs |
title_full_unstemmed | Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs |
title_short | Mechanical Behavior of Elastic Self-Locking Nails for Intramedullary Fracture Fixation: A Numerical Analysis of Innovative Nail Designs |
title_sort | mechanical behavior of elastic self-locking nails for intramedullary fracture fixation: a numerical analysis of innovative nail designs |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7289914/ https://www.ncbi.nlm.nih.gov/pubmed/32582675 http://dx.doi.org/10.3389/fbioe.2020.00557 |
work_keys_str_mv | AT putamegiovanni mechanicalbehaviorofelasticselflockingnailsforintramedullaryfracturefixationanumericalanalysisofinnovativenaildesigns AT pascolettigiulia mechanicalbehaviorofelasticselflockingnailsforintramedullaryfracturefixationanumericalanalysisofinnovativenaildesigns AT terzinimara mechanicalbehaviorofelasticselflockingnailsforintramedullaryfracturefixationanumericalanalysisofinnovativenaildesigns AT zanettielisabettam mechanicalbehaviorofelasticselflockingnailsforintramedullaryfracturefixationanumericalanalysisofinnovativenaildesigns AT audeninoalbertol mechanicalbehaviorofelasticselflockingnailsforintramedullaryfracturefixationanumericalanalysisofinnovativenaildesigns |