Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS)

The aim of this retrospective clinical study was to determine if there is a reduction in the overall treatment duration in orthodontic patients using low-intensity pulsed ultrasound (LIPUS) and Invisalign SmartTrack® clear aligners. Data were collected from the first thirty-four patients (9 males, 2...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaur, Harmanpreet, El-Bialy, Tarek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7290339/
https://www.ncbi.nlm.nih.gov/pubmed/32370099
http://dx.doi.org/10.3390/jcm9051303
_version_ 1783545653284044800
author Kaur, Harmanpreet
El-Bialy, Tarek
author_facet Kaur, Harmanpreet
El-Bialy, Tarek
author_sort Kaur, Harmanpreet
collection PubMed
description The aim of this retrospective clinical study was to determine if there is a reduction in the overall treatment duration in orthodontic patients using low-intensity pulsed ultrasound (LIPUS) and Invisalign SmartTrack® clear aligners. Data were collected from the first thirty-four patients (9 males, 25 females; average age 41.37 ± 15.02) who finished their orthodontic treatment using an intraoral LIPUS device and Invisalign clear aligners in a private clinic. The LIPUS parameters used by patients at home for 20 min/day were: ultrasonic frequency 1.5 MHz, pulse duration 200µs, pulse repetition rate 1 kHz, and spatial average-temporal average intensity 30mW/cm(2). A control group (11 males, 23 females; average age 31.36 ± 14.41) matching for the same malocclusions was randomly selected from finished treatment cases of the same clinician. The date of first Invisalign attachment placement and first use of LIPUS application was recorded as T0, and the date of retainer delivery was recorded as T1. The treatment duration (T1–T0) and treatment reduction percentage with LIPUS device were collected and analyzed using two-sample t-test in Microsoft Excel. Treatment duration was significantly reduced in the LIPUS group (541.44 ± 192.23 days) compared to control group (1061.05 ± 455.64 days) (p < 0.05). The LIPUS group showed on average 49% reduction in the overall treatment time as compared to the control group. The average compliance of the patients using LIPUS was 66.02%. Patients who used LIPUS showed a clinically significant reduction in the overall orthodontic treatment duration compared to the control group who used Invisalign clear aligners only.
format Online
Article
Text
id pubmed-7290339
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72903392020-06-15 Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS) Kaur, Harmanpreet El-Bialy, Tarek J Clin Med Article The aim of this retrospective clinical study was to determine if there is a reduction in the overall treatment duration in orthodontic patients using low-intensity pulsed ultrasound (LIPUS) and Invisalign SmartTrack® clear aligners. Data were collected from the first thirty-four patients (9 males, 25 females; average age 41.37 ± 15.02) who finished their orthodontic treatment using an intraoral LIPUS device and Invisalign clear aligners in a private clinic. The LIPUS parameters used by patients at home for 20 min/day were: ultrasonic frequency 1.5 MHz, pulse duration 200µs, pulse repetition rate 1 kHz, and spatial average-temporal average intensity 30mW/cm(2). A control group (11 males, 23 females; average age 31.36 ± 14.41) matching for the same malocclusions was randomly selected from finished treatment cases of the same clinician. The date of first Invisalign attachment placement and first use of LIPUS application was recorded as T0, and the date of retainer delivery was recorded as T1. The treatment duration (T1–T0) and treatment reduction percentage with LIPUS device were collected and analyzed using two-sample t-test in Microsoft Excel. Treatment duration was significantly reduced in the LIPUS group (541.44 ± 192.23 days) compared to control group (1061.05 ± 455.64 days) (p < 0.05). The LIPUS group showed on average 49% reduction in the overall treatment time as compared to the control group. The average compliance of the patients using LIPUS was 66.02%. Patients who used LIPUS showed a clinically significant reduction in the overall orthodontic treatment duration compared to the control group who used Invisalign clear aligners only. MDPI 2020-05-01 /pmc/articles/PMC7290339/ /pubmed/32370099 http://dx.doi.org/10.3390/jcm9051303 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kaur, Harmanpreet
El-Bialy, Tarek
Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS)
title Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS)
title_full Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS)
title_fullStr Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS)
title_full_unstemmed Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS)
title_short Shortening of Overall Orthodontic Treatment Duration with Low-Intensity Pulsed Ultrasound (LIPUS)
title_sort shortening of overall orthodontic treatment duration with low-intensity pulsed ultrasound (lipus)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7290339/
https://www.ncbi.nlm.nih.gov/pubmed/32370099
http://dx.doi.org/10.3390/jcm9051303
work_keys_str_mv AT kaurharmanpreet shorteningofoverallorthodontictreatmentdurationwithlowintensitypulsedultrasoundlipus
AT elbialytarek shorteningofoverallorthodontictreatmentdurationwithlowintensitypulsedultrasoundlipus