Cargando…
Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants
The aim of this study was to compare the efficacy of the intraoperative bending of titanium mesh with the efficacy of pre-contoured “hybrid” patient-specific titanium mesh for the surgical repair of isolated orbital floor fractures. In-house 3D-printed anatomical models were used as bending guides....
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7291031/ https://www.ncbi.nlm.nih.gov/pubmed/32455967 http://dx.doi.org/10.3390/jcm9051579 |
_version_ | 1783545815261773824 |
---|---|
author | Sigron, Guido R. Rüedi, Nathalie Chammartin, Frédérique Meyer, Simon Msallem, Bilal Kunz, Christoph Thieringer, Florian M. |
author_facet | Sigron, Guido R. Rüedi, Nathalie Chammartin, Frédérique Meyer, Simon Msallem, Bilal Kunz, Christoph Thieringer, Florian M. |
author_sort | Sigron, Guido R. |
collection | PubMed |
description | The aim of this study was to compare the efficacy of the intraoperative bending of titanium mesh with the efficacy of pre-contoured “hybrid” patient-specific titanium mesh for the surgical repair of isolated orbital floor fractures. In-house 3D-printed anatomical models were used as bending guides. The main outcome measures were preoperative and postoperative orbital volume and surgery time. We performed a retrospective cohort study including 22 patients who had undergone surgery between May 2016 and November 2018. The first twelve patients underwent conventional reconstruction with intraoperative free-hand bending of an orbital floor mesh plate. The subsequent ten patients received pre-contoured plates based on 3D-printed orbital models that were produced by mirroring the non-fractured orbit of the patient using a medical imaging software. We compared the preoperative and postoperative absolute volume difference (unfractured orbit, fractured orbit), the fracture area, the fracture collapse, and the effective surgery time between the two groups. In comparison to the intraoperative bending of titanium mesh, the application of preformed plates based on a 3D-printed orbital model resulted in a non-significant absolute volume difference in the intervention group (p = 0.276) and statistically significant volume difference in the conventional group (p = 0.002). Further, there was a significant reduction of the surgery time (57.3 ± 23.4 min versus 99.8 ± 28.9 min, p = 0.001). The results of this study suggest that the use of 3D-printed orbital models leads to a more accurate reconstruction and a time reduction during surgery. |
format | Online Article Text |
id | pubmed-7291031 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72910312020-06-17 Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants Sigron, Guido R. Rüedi, Nathalie Chammartin, Frédérique Meyer, Simon Msallem, Bilal Kunz, Christoph Thieringer, Florian M. J Clin Med Article The aim of this study was to compare the efficacy of the intraoperative bending of titanium mesh with the efficacy of pre-contoured “hybrid” patient-specific titanium mesh for the surgical repair of isolated orbital floor fractures. In-house 3D-printed anatomical models were used as bending guides. The main outcome measures were preoperative and postoperative orbital volume and surgery time. We performed a retrospective cohort study including 22 patients who had undergone surgery between May 2016 and November 2018. The first twelve patients underwent conventional reconstruction with intraoperative free-hand bending of an orbital floor mesh plate. The subsequent ten patients received pre-contoured plates based on 3D-printed orbital models that were produced by mirroring the non-fractured orbit of the patient using a medical imaging software. We compared the preoperative and postoperative absolute volume difference (unfractured orbit, fractured orbit), the fracture area, the fracture collapse, and the effective surgery time between the two groups. In comparison to the intraoperative bending of titanium mesh, the application of preformed plates based on a 3D-printed orbital model resulted in a non-significant absolute volume difference in the intervention group (p = 0.276) and statistically significant volume difference in the conventional group (p = 0.002). Further, there was a significant reduction of the surgery time (57.3 ± 23.4 min versus 99.8 ± 28.9 min, p = 0.001). The results of this study suggest that the use of 3D-printed orbital models leads to a more accurate reconstruction and a time reduction during surgery. MDPI 2020-05-22 /pmc/articles/PMC7291031/ /pubmed/32455967 http://dx.doi.org/10.3390/jcm9051579 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sigron, Guido R. Rüedi, Nathalie Chammartin, Frédérique Meyer, Simon Msallem, Bilal Kunz, Christoph Thieringer, Florian M. Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants |
title | Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants |
title_full | Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants |
title_fullStr | Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants |
title_full_unstemmed | Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants |
title_short | Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants |
title_sort | three-dimensional analysis of isolated orbital floor fractures pre- and post-reconstruction with standard titanium meshes and “hybrid” patient-specific implants |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7291031/ https://www.ncbi.nlm.nih.gov/pubmed/32455967 http://dx.doi.org/10.3390/jcm9051579 |
work_keys_str_mv | AT sigronguidor threedimensionalanalysisofisolatedorbitalfloorfracturespreandpostreconstructionwithstandardtitaniummeshesandhybridpatientspecificimplants AT ruedinathalie threedimensionalanalysisofisolatedorbitalfloorfracturespreandpostreconstructionwithstandardtitaniummeshesandhybridpatientspecificimplants AT chammartinfrederique threedimensionalanalysisofisolatedorbitalfloorfracturespreandpostreconstructionwithstandardtitaniummeshesandhybridpatientspecificimplants AT meyersimon threedimensionalanalysisofisolatedorbitalfloorfracturespreandpostreconstructionwithstandardtitaniummeshesandhybridpatientspecificimplants AT msallembilal threedimensionalanalysisofisolatedorbitalfloorfracturespreandpostreconstructionwithstandardtitaniummeshesandhybridpatientspecificimplants AT kunzchristoph threedimensionalanalysisofisolatedorbitalfloorfracturespreandpostreconstructionwithstandardtitaniummeshesandhybridpatientspecificimplants AT thieringerflorianm threedimensionalanalysisofisolatedorbitalfloorfracturespreandpostreconstructionwithstandardtitaniummeshesandhybridpatientspecificimplants |