Clinical Outcomes and Risk Factors for Tunneled Hemodialysis Catheter-Related Bloodstream Infections

Diabetes and left internal jugular vein insertion site were significantly associated with increased risk of a catheter-related bloodstream infection from a tunneled hemodialysis catheter. Ex-smoker status was significantly associated with reduced risk.