Cargando…
Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
INTRODUCTION: We report on the management of intraoperative vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy for vaginal vault prolapse with defecatory dysfunction. CASE PRESENTATION: A 75‐year‐old woman with vaginal bulge and constipation was to undergo a joint robotic mes...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7292113/ https://www.ncbi.nlm.nih.gov/pubmed/32743477 http://dx.doi.org/10.1002/iju5.12138 |
_version_ | 1783546040849268736 |
---|---|
author | Chavez, Jacqueline Finsterbusch, Carlos Olson, Craig Zimmern, Philippe E |
author_facet | Chavez, Jacqueline Finsterbusch, Carlos Olson, Craig Zimmern, Philippe E |
author_sort | Chavez, Jacqueline |
collection | PubMed |
description | INTRODUCTION: We report on the management of intraoperative vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy for vaginal vault prolapse with defecatory dysfunction. CASE PRESENTATION: A 75‐year‐old woman with vaginal bulge and constipation was to undergo a joint robotic mesh recto‐sacrocolpopexy. Intraoperatively, mesh was secured to the left posterior vaginal wall following dissection. Prior to contralateral suture placement, the vaginal cuff split open and exposed an end‐to‐end anastomotic sizer previously inserted in the vagina. Due to subsequent mesh erosion risk, we proceeded with vaginotomy closure with running and interrupted absorbable sutures, removal of mesh, direct suture rectopexy to the promontory, and enterocele defect correction by reapproximating the right and left wings of the peritoneum flaps over the rectum with running sutures. Patient reported satisfactory outcomes after 2 years. CONCLUSION: We reviewed our experience with vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy prompting enterocele repair and rectopexy without mesh. |
format | Online Article Text |
id | pubmed-7292113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-72921132020-07-30 Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy Chavez, Jacqueline Finsterbusch, Carlos Olson, Craig Zimmern, Philippe E IJU Case Rep Case Reports INTRODUCTION: We report on the management of intraoperative vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy for vaginal vault prolapse with defecatory dysfunction. CASE PRESENTATION: A 75‐year‐old woman with vaginal bulge and constipation was to undergo a joint robotic mesh recto‐sacrocolpopexy. Intraoperatively, mesh was secured to the left posterior vaginal wall following dissection. Prior to contralateral suture placement, the vaginal cuff split open and exposed an end‐to‐end anastomotic sizer previously inserted in the vagina. Due to subsequent mesh erosion risk, we proceeded with vaginotomy closure with running and interrupted absorbable sutures, removal of mesh, direct suture rectopexy to the promontory, and enterocele defect correction by reapproximating the right and left wings of the peritoneum flaps over the rectum with running sutures. Patient reported satisfactory outcomes after 2 years. CONCLUSION: We reviewed our experience with vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy prompting enterocele repair and rectopexy without mesh. John Wiley and Sons Inc. 2020-02-29 /pmc/articles/PMC7292113/ /pubmed/32743477 http://dx.doi.org/10.1002/iju5.12138 Text en © 2020 The Authors. IJU Case Reports published by John Wiley & Sons Australia, Ltd on behalf of the Japanese Urological Association. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Reports Chavez, Jacqueline Finsterbusch, Carlos Olson, Craig Zimmern, Philippe E Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy |
title | Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy |
title_full | Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy |
title_fullStr | Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy |
title_full_unstemmed | Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy |
title_short | Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy |
title_sort | vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7292113/ https://www.ncbi.nlm.nih.gov/pubmed/32743477 http://dx.doi.org/10.1002/iju5.12138 |
work_keys_str_mv | AT chavezjacqueline vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy AT finsterbuschcarlos vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy AT olsoncraig vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy AT zimmernphilippee vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy |