Cargando…

Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy

INTRODUCTION: We report on the management of intraoperative vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy for vaginal vault prolapse with defecatory dysfunction. CASE PRESENTATION: A 75‐year‐old woman with vaginal bulge and constipation was to undergo a joint robotic mes...

Descripción completa

Detalles Bibliográficos
Autores principales: Chavez, Jacqueline, Finsterbusch, Carlos, Olson, Craig, Zimmern, Philippe E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7292113/
https://www.ncbi.nlm.nih.gov/pubmed/32743477
http://dx.doi.org/10.1002/iju5.12138
_version_ 1783546040849268736
author Chavez, Jacqueline
Finsterbusch, Carlos
Olson, Craig
Zimmern, Philippe E
author_facet Chavez, Jacqueline
Finsterbusch, Carlos
Olson, Craig
Zimmern, Philippe E
author_sort Chavez, Jacqueline
collection PubMed
description INTRODUCTION: We report on the management of intraoperative vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy for vaginal vault prolapse with defecatory dysfunction. CASE PRESENTATION: A 75‐year‐old woman with vaginal bulge and constipation was to undergo a joint robotic mesh recto‐sacrocolpopexy. Intraoperatively, mesh was secured to the left posterior vaginal wall following dissection. Prior to contralateral suture placement, the vaginal cuff split open and exposed an end‐to‐end anastomotic sizer previously inserted in the vagina. Due to subsequent mesh erosion risk, we proceeded with vaginotomy closure with running and interrupted absorbable sutures, removal of mesh, direct suture rectopexy to the promontory, and enterocele defect correction by reapproximating the right and left wings of the peritoneum flaps over the rectum with running sutures. Patient reported satisfactory outcomes after 2 years. CONCLUSION: We reviewed our experience with vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy prompting enterocele repair and rectopexy without mesh.
format Online
Article
Text
id pubmed-7292113
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-72921132020-07-30 Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy Chavez, Jacqueline Finsterbusch, Carlos Olson, Craig Zimmern, Philippe E IJU Case Rep Case Reports INTRODUCTION: We report on the management of intraoperative vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy for vaginal vault prolapse with defecatory dysfunction. CASE PRESENTATION: A 75‐year‐old woman with vaginal bulge and constipation was to undergo a joint robotic mesh recto‐sacrocolpopexy. Intraoperatively, mesh was secured to the left posterior vaginal wall following dissection. Prior to contralateral suture placement, the vaginal cuff split open and exposed an end‐to‐end anastomotic sizer previously inserted in the vagina. Due to subsequent mesh erosion risk, we proceeded with vaginotomy closure with running and interrupted absorbable sutures, removal of mesh, direct suture rectopexy to the promontory, and enterocele defect correction by reapproximating the right and left wings of the peritoneum flaps over the rectum with running sutures. Patient reported satisfactory outcomes after 2 years. CONCLUSION: We reviewed our experience with vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy prompting enterocele repair and rectopexy without mesh. John Wiley and Sons Inc. 2020-02-29 /pmc/articles/PMC7292113/ /pubmed/32743477 http://dx.doi.org/10.1002/iju5.12138 Text en © 2020 The Authors. IJU Case Reports published by John Wiley & Sons Australia, Ltd on behalf of the Japanese Urological Association. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Reports
Chavez, Jacqueline
Finsterbusch, Carlos
Olson, Craig
Zimmern, Philippe E
Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
title Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
title_full Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
title_fullStr Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
title_full_unstemmed Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
title_short Vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
title_sort vaginal cuff perforation during robotic‐assisted mesh recto‐sacrocolpopexy
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7292113/
https://www.ncbi.nlm.nih.gov/pubmed/32743477
http://dx.doi.org/10.1002/iju5.12138
work_keys_str_mv AT chavezjacqueline vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy
AT finsterbuschcarlos vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy
AT olsoncraig vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy
AT zimmernphilippee vaginalcuffperforationduringroboticassistedmeshrectosacrocolpopexy