Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning

OBJECTIVES: To compare the linear measurements from digital panoramic (DP) radiographs and cone-beam computed tomography (CBCT) volumes for the localization of the mental foramen (MF). MATERIAL AND METHODS: Thirty-one patients with panoramic and CBCT radiographs depicted on the same machine were ana...

Descripción completa

Detalles Bibliográficos
Autores principales: Beshtawi, Khaled, Qirresh, Emad, Parker, Mohamed, Shaik, Shoayeb
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Scientific Scholar 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7294321/
https://www.ncbi.nlm.nih.gov/pubmed/32547837
http://dx.doi.org/10.25259/JCIS_150_2019
_version_ 1783546468646256640
author Beshtawi, Khaled
Qirresh, Emad
Parker, Mohamed
Shaik, Shoayeb
author_facet Beshtawi, Khaled
Qirresh, Emad
Parker, Mohamed
Shaik, Shoayeb
author_sort Beshtawi, Khaled
collection PubMed
description OBJECTIVES: To compare the linear measurements from digital panoramic (DP) radiographs and cone-beam computed tomography (CBCT) volumes for the localization of the mental foramen (MF). MATERIAL AND METHODS: Thirty-one patients with panoramic and CBCT radiographs depicted on the same machine were analyzed. The vertical and horizontal positions of the MF were compared by the differences in distances measured from reference points to the boundaries (tangents) of the MF in digital panoramic (DP) and CBCT reformatted panoramic (CRP) views. The vertical position of MF was also analyzed on CBCT oblique coronal views (CORO) and compared with its corresponding distances on DP and CRP views. RESULTS: Statistically significant differences (P < 0.05) were found in all compared measurements between CRP and DP views. In addition, the vertical distance (Y1) compared between DP, CRP, and CORO views also showed a statistically significant measurement discrepancy in the mean distance (P < 0.000) with the highest mean difference of 1.59 mm (P < 0.05) was attained from Y1 (DP-CORO). Inter- and intra-examiner analysis indicated a high level of agreement for all measurements. CONCLUSION: The mean values of discrepancies in measurements between DP and CRP views for horizontal and vertical linear measurements were clinically tolerable. Nevertheless, significant differences in the vertical MF position were detected between the panoramic views (DP, CRP) and the coronal views (CORO). This implies that the use of coronal view measurements during implant planning might reduce the risk of neurovascular injuries.
format Online
Article
Text
id pubmed-7294321
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Scientific Scholar
record_format MEDLINE/PubMed
spelling pubmed-72943212020-06-15 Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning Beshtawi, Khaled Qirresh, Emad Parker, Mohamed Shaik, Shoayeb J Clin Imaging Sci Original Research OBJECTIVES: To compare the linear measurements from digital panoramic (DP) radiographs and cone-beam computed tomography (CBCT) volumes for the localization of the mental foramen (MF). MATERIAL AND METHODS: Thirty-one patients with panoramic and CBCT radiographs depicted on the same machine were analyzed. The vertical and horizontal positions of the MF were compared by the differences in distances measured from reference points to the boundaries (tangents) of the MF in digital panoramic (DP) and CBCT reformatted panoramic (CRP) views. The vertical position of MF was also analyzed on CBCT oblique coronal views (CORO) and compared with its corresponding distances on DP and CRP views. RESULTS: Statistically significant differences (P < 0.05) were found in all compared measurements between CRP and DP views. In addition, the vertical distance (Y1) compared between DP, CRP, and CORO views also showed a statistically significant measurement discrepancy in the mean distance (P < 0.000) with the highest mean difference of 1.59 mm (P < 0.05) was attained from Y1 (DP-CORO). Inter- and intra-examiner analysis indicated a high level of agreement for all measurements. CONCLUSION: The mean values of discrepancies in measurements between DP and CRP views for horizontal and vertical linear measurements were clinically tolerable. Nevertheless, significant differences in the vertical MF position were detected between the panoramic views (DP, CRP) and the coronal views (CORO). This implies that the use of coronal view measurements during implant planning might reduce the risk of neurovascular injuries. Scientific Scholar 2020-06-08 /pmc/articles/PMC7294321/ /pubmed/32547837 http://dx.doi.org/10.25259/JCIS_150_2019 Text en © 2020 Published by Scientific Scholar on behalf of Journal of Clinical Imaging Science https://creativecommons.org/licenses/by-nc-sa/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Research
Beshtawi, Khaled
Qirresh, Emad
Parker, Mohamed
Shaik, Shoayeb
Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning
title Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning
title_full Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning
title_fullStr Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning
title_full_unstemmed Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning
title_short Custom Focal Trough in Cone-Beam Computed Tomography Reformatted Panoramic Versus Digital Panoramic for Mental Foramen Position to Aid Implant Planning
title_sort custom focal trough in cone-beam computed tomography reformatted panoramic versus digital panoramic for mental foramen position to aid implant planning
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7294321/
https://www.ncbi.nlm.nih.gov/pubmed/32547837
http://dx.doi.org/10.25259/JCIS_150_2019
work_keys_str_mv AT beshtawikhaled customfocaltroughinconebeamcomputedtomographyreformattedpanoramicversusdigitalpanoramicformentalforamenpositiontoaidimplantplanning
AT qirreshemad customfocaltroughinconebeamcomputedtomographyreformattedpanoramicversusdigitalpanoramicformentalforamenpositiontoaidimplantplanning
AT parkermohamed customfocaltroughinconebeamcomputedtomographyreformattedpanoramicversusdigitalpanoramicformentalforamenpositiontoaidimplantplanning
AT shaikshoayeb customfocaltroughinconebeamcomputedtomographyreformattedpanoramicversusdigitalpanoramicformentalforamenpositiontoaidimplantplanning