Cargando…

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite t...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Changyeop, Cho, Gyuseong, Unruh, Troy, Hur, Seop, Kwon, Inyong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7294422/
https://www.ncbi.nlm.nih.gov/pubmed/32408675
http://dx.doi.org/10.3390/s20102765
_version_ 1783546483900940288
author Lee, Changyeop
Cho, Gyuseong
Unruh, Troy
Hur, Seop
Kwon, Inyong
author_facet Lee, Changyeop
Cho, Gyuseong
Unruh, Troy
Hur, Seop
Kwon, Inyong
author_sort Lee, Changyeop
collection PubMed
description According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.
format Online
Article
Text
id pubmed-7294422
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72944222020-08-13 Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad Lee, Changyeop Cho, Gyuseong Unruh, Troy Hur, Seop Kwon, Inyong Sensors (Basel) Article According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures. MDPI 2020-05-12 /pmc/articles/PMC7294422/ /pubmed/32408675 http://dx.doi.org/10.3390/s20102765 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Changyeop
Cho, Gyuseong
Unruh, Troy
Hur, Seop
Kwon, Inyong
Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad
title Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad
title_full Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad
title_fullStr Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad
title_full_unstemmed Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad
title_short Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad
title_sort integrated circuit design for radiation-hardened charge-sensitive amplifier survived up to 2 mrad
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7294422/
https://www.ncbi.nlm.nih.gov/pubmed/32408675
http://dx.doi.org/10.3390/s20102765
work_keys_str_mv AT leechangyeop integratedcircuitdesignforradiationhardenedchargesensitiveamplifiersurvivedupto2mrad
AT chogyuseong integratedcircuitdesignforradiationhardenedchargesensitiveamplifiersurvivedupto2mrad
AT unruhtroy integratedcircuitdesignforradiationhardenedchargesensitiveamplifiersurvivedupto2mrad
AT hurseop integratedcircuitdesignforradiationhardenedchargesensitiveamplifiersurvivedupto2mrad
AT kwoninyong integratedcircuitdesignforradiationhardenedchargesensitiveamplifiersurvivedupto2mrad