Cargando…

Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities

Aim To study ground-glass opacities (GGO) not only from the coronavirus 2019 (COVID-19) pneumonia” perspective but also as a radiological presentation of other pathologies with comparable features. Methods We enrolled 33 patients admitted to Policlinico Universitario G. B. Rossi who underwent non-co...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehrabi, Sara, Fontana, Silvia, Mambrin, Francesca, Nguyen, Hoang Quyen, Righi, Elda, Tacconelli, Evelina, Mansueto, Giancarlo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7294903/
https://www.ncbi.nlm.nih.gov/pubmed/32550070
http://dx.doi.org/10.7759/cureus.8151
_version_ 1783546562934210560
author Mehrabi, Sara
Fontana, Silvia
Mambrin, Francesca
Nguyen, Hoang Quyen
Righi, Elda
Tacconelli, Evelina
Mansueto, Giancarlo
author_facet Mehrabi, Sara
Fontana, Silvia
Mambrin, Francesca
Nguyen, Hoang Quyen
Righi, Elda
Tacconelli, Evelina
Mansueto, Giancarlo
author_sort Mehrabi, Sara
collection PubMed
description Aim To study ground-glass opacities (GGO) not only from the coronavirus 2019 (COVID-19) pneumonia” perspective but also as a radiological presentation of other pathologies with comparable features. Methods We enrolled 33 patients admitted to Policlinico Universitario G. B. Rossi who underwent non-contrast-enhanced (NCE) or contrast-enhanced (CE) chest computed tomography (CT) between March 12 and April 12. All patients with CT-detected ground-glass opacity (GGO) were included. All patients resulted as COVID-19 negative at the reverse transcription-polymerase chain reaction (RT-PCR) assay. We studied the different pathologies underlying GGO features: neoplastic diseases and non-neoplastic diseases (viral pneumonias, interstitial pneumonias, and cardiopulmonary diseases) in order to avoid pitfalls and to reach the correct diagnosis. Results All CT scans detected GGOs. Symptomatic patients were 25/33 (75.7%). At the clinical presentation, they reported fever and dry cough; in six out of 25 cases, dyspnea was also reported (24%). Thirty-three (33; 100%) showed GGO at CT: 15/33 (45.45%) presented pure GGO, and 18/33 (54.54%) showed GGO with consolidation. The RT-PCR assay was negative in 100%. We investigated other potential underlying diseases to explain imaging features: neoplastic causes (8/33, 24.24%) and non-neoplastic causes, in particular, infectious pneumonias (16/33, 48,48 %, viral and fungal), interstitial pneumonias (4/33, 12,12%), and cardio-pulmonary disease (5/33, 15,15%). Conclusions GGO remains a diagnostic challenge. Although CT represents a fundamental diagnostic tool because of its sensitivity, it still needs to be integrated with clinical data to achieve the best clinical management. In the presence of typical imaging features (e.g. GGO and consolidation), the radiologist should focus on the pandemic and manage a suspect patient as COVID-19 positive until proven to be negative.
format Online
Article
Text
id pubmed-7294903
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-72949032020-06-16 Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities Mehrabi, Sara Fontana, Silvia Mambrin, Francesca Nguyen, Hoang Quyen Righi, Elda Tacconelli, Evelina Mansueto, Giancarlo Cureus Radiology Aim To study ground-glass opacities (GGO) not only from the coronavirus 2019 (COVID-19) pneumonia” perspective but also as a radiological presentation of other pathologies with comparable features. Methods We enrolled 33 patients admitted to Policlinico Universitario G. B. Rossi who underwent non-contrast-enhanced (NCE) or contrast-enhanced (CE) chest computed tomography (CT) between March 12 and April 12. All patients with CT-detected ground-glass opacity (GGO) were included. All patients resulted as COVID-19 negative at the reverse transcription-polymerase chain reaction (RT-PCR) assay. We studied the different pathologies underlying GGO features: neoplastic diseases and non-neoplastic diseases (viral pneumonias, interstitial pneumonias, and cardiopulmonary diseases) in order to avoid pitfalls and to reach the correct diagnosis. Results All CT scans detected GGOs. Symptomatic patients were 25/33 (75.7%). At the clinical presentation, they reported fever and dry cough; in six out of 25 cases, dyspnea was also reported (24%). Thirty-three (33; 100%) showed GGO at CT: 15/33 (45.45%) presented pure GGO, and 18/33 (54.54%) showed GGO with consolidation. The RT-PCR assay was negative in 100%. We investigated other potential underlying diseases to explain imaging features: neoplastic causes (8/33, 24.24%) and non-neoplastic causes, in particular, infectious pneumonias (16/33, 48,48 %, viral and fungal), interstitial pneumonias (4/33, 12,12%), and cardio-pulmonary disease (5/33, 15,15%). Conclusions GGO remains a diagnostic challenge. Although CT represents a fundamental diagnostic tool because of its sensitivity, it still needs to be integrated with clinical data to achieve the best clinical management. In the presence of typical imaging features (e.g. GGO and consolidation), the radiologist should focus on the pandemic and manage a suspect patient as COVID-19 positive until proven to be negative. Cureus 2020-05-16 /pmc/articles/PMC7294903/ /pubmed/32550070 http://dx.doi.org/10.7759/cureus.8151 Text en Copyright © 2020, Mehrabi et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Radiology
Mehrabi, Sara
Fontana, Silvia
Mambrin, Francesca
Nguyen, Hoang Quyen
Righi, Elda
Tacconelli, Evelina
Mansueto, Giancarlo
Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities
title Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities
title_full Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities
title_fullStr Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities
title_full_unstemmed Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities
title_short Pitfalls of Computed Tomography in the Coronavirus 2019 (COVID-19) Era: A New Perspective on Ground-Glass Opacities
title_sort pitfalls of computed tomography in the coronavirus 2019 (covid-19) era: a new perspective on ground-glass opacities
topic Radiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7294903/
https://www.ncbi.nlm.nih.gov/pubmed/32550070
http://dx.doi.org/10.7759/cureus.8151
work_keys_str_mv AT mehrabisara pitfallsofcomputedtomographyinthecoronavirus2019covid19eraanewperspectiveongroundglassopacities
AT fontanasilvia pitfallsofcomputedtomographyinthecoronavirus2019covid19eraanewperspectiveongroundglassopacities
AT mambrinfrancesca pitfallsofcomputedtomographyinthecoronavirus2019covid19eraanewperspectiveongroundglassopacities
AT nguyenhoangquyen pitfallsofcomputedtomographyinthecoronavirus2019covid19eraanewperspectiveongroundglassopacities
AT righielda pitfallsofcomputedtomographyinthecoronavirus2019covid19eraanewperspectiveongroundglassopacities
AT tacconellievelina pitfallsofcomputedtomographyinthecoronavirus2019covid19eraanewperspectiveongroundglassopacities
AT mansuetogiancarlo pitfallsofcomputedtomographyinthecoronavirus2019covid19eraanewperspectiveongroundglassopacities