Cargando…
Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails
Femoral neck stress fractures are rare and when treating are difficult to achieve favorable outcomes. This study characterizes outcomes associated with the use of cephalomedullary nails for fixation of Pauwels type-3 vertical femoral neck undisplaced-incomplete insufficiency fractures. Four consecut...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Hip Society
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7295618/ https://www.ncbi.nlm.nih.gov/pubmed/32566542 http://dx.doi.org/10.5371/hp.2020.32.2.105 |
_version_ | 1783546684191539200 |
---|---|
author | Song, Joo-Hyoun Kim, Jongmin Oh, Seungbae |
author_facet | Song, Joo-Hyoun Kim, Jongmin Oh, Seungbae |
author_sort | Song, Joo-Hyoun |
collection | PubMed |
description | Femoral neck stress fractures are rare and when treating are difficult to achieve favorable outcomes. This study characterizes outcomes associated with the use of cephalomedullary nails for fixation of Pauwels type-3 vertical femoral neck undisplaced-incomplete insufficiency fractures. Four consecutive patients with a Pauwels type-3 vertical femoral neck tensile insufficiency fracture from 2016 to 2018 were reviewed. Magnetic resonance imaging data revealed tensile visible fracture lines and hip-joint effusions with a high shear angle. For all patients, bone mineral density and vitamin D levels were low; vitamin D therapy was initiated immediately. Surgical procedures were conducted with cephalomedullary nails (Gamma 3 locking nail system; Stryker) under general anesthesia. A cephalomedullary nail appears to be a safe and effective alternative to the use of multiple parallel screws or a sliding hip screw for fixation of vertical femoral neck stress fractures (level of evidence: Level V). |
format | Online Article Text |
id | pubmed-7295618 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Hip Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-72956182020-06-18 Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails Song, Joo-Hyoun Kim, Jongmin Oh, Seungbae Hip Pelvis Case Report Femoral neck stress fractures are rare and when treating are difficult to achieve favorable outcomes. This study characterizes outcomes associated with the use of cephalomedullary nails for fixation of Pauwels type-3 vertical femoral neck undisplaced-incomplete insufficiency fractures. Four consecutive patients with a Pauwels type-3 vertical femoral neck tensile insufficiency fracture from 2016 to 2018 were reviewed. Magnetic resonance imaging data revealed tensile visible fracture lines and hip-joint effusions with a high shear angle. For all patients, bone mineral density and vitamin D levels were low; vitamin D therapy was initiated immediately. Surgical procedures were conducted with cephalomedullary nails (Gamma 3 locking nail system; Stryker) under general anesthesia. A cephalomedullary nail appears to be a safe and effective alternative to the use of multiple parallel screws or a sliding hip screw for fixation of vertical femoral neck stress fractures (level of evidence: Level V). Korean Hip Society 2020-06 2020-06-15 /pmc/articles/PMC7295618/ /pubmed/32566542 http://dx.doi.org/10.5371/hp.2020.32.2.105 Text en Copyright © 2020 by Korean Hip Society http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Song, Joo-Hyoun Kim, Jongmin Oh, Seungbae Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails |
title | Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails |
title_full | Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails |
title_fullStr | Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails |
title_full_unstemmed | Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails |
title_short | Internal Fixation of Pauwels Type-3 Undisplaced-incomplete Insufficiency Femoral Neck Fractures with Cephalomedullary Nails |
title_sort | internal fixation of pauwels type-3 undisplaced-incomplete insufficiency femoral neck fractures with cephalomedullary nails |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7295618/ https://www.ncbi.nlm.nih.gov/pubmed/32566542 http://dx.doi.org/10.5371/hp.2020.32.2.105 |
work_keys_str_mv | AT songjoohyoun internalfixationofpauwelstype3undisplacedincompleteinsufficiencyfemoralneckfractureswithcephalomedullarynails AT kimjongmin internalfixationofpauwelstype3undisplacedincompleteinsufficiencyfemoralneckfractureswithcephalomedullarynails AT ohseungbae internalfixationofpauwelstype3undisplacedincompleteinsufficiencyfemoralneckfractureswithcephalomedullarynails |