Minimal internal limiting membrane peeling with ILM flap technique for idiopathic macular holes: a preliminary study

BACKGROUND: Internal limiting membrane (ILM) peeling increases the idiopathic macular hole (IMH) closure rate but causes the inner retina dimplings. This study is to introduce a method to minimally peel the ILM, and with the ILM flap to ensure the IMH closure. METHODS: Twelve consecutive IMH eyes we...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Zizhong, Qian, Huiming, Fransisca, Silvia, Gu, Xunyi, Ji, Jiangdong, Wang, Jianan, Liu, Qinghuai, Xie, Ping