Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines

The prevention of nosocomial infections is an imperative task. The dental chair unit (DCU) is an indispensable device used in dental treatment. However, it is known that the dental unit water line (DUWL) can become contaminated with biofilm, consisting mainly of heterotrophic bacteria (HB). Recently...

Descripción completa

Detalles Bibliográficos
Autores principales: Okubo, Keisuke, Ito, Takashi, Okamoto, Kentaro, Yamamoto, Ichiro, Mizutani, Hajime, Kawata, Yusuke, Shiota, Yasuyoshi, Ito, Masahiro, Nakamura, Shin, Tai, Masako, Yamamoto, Tadashi, Takashiba, Shogo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7298401/
https://www.ncbi.nlm.nih.gov/pubmed/32566782
http://dx.doi.org/10.1016/j.heliyon.2020.e04132
_version_ 1783547196143042560
author Okubo, Keisuke
Ito, Takashi
Okamoto, Kentaro
Yamamoto, Ichiro
Mizutani, Hajime
Kawata, Yusuke
Shiota, Yasuyoshi
Ito, Masahiro
Nakamura, Shin
Tai, Masako
Yamamoto, Tadashi
Takashiba, Shogo
author_facet Okubo, Keisuke
Ito, Takashi
Okamoto, Kentaro
Yamamoto, Ichiro
Mizutani, Hajime
Kawata, Yusuke
Shiota, Yasuyoshi
Ito, Masahiro
Nakamura, Shin
Tai, Masako
Yamamoto, Tadashi
Takashiba, Shogo
author_sort Okubo, Keisuke
collection PubMed
description The prevention of nosocomial infections is an imperative task. The dental chair unit (DCU) is an indispensable device used in dental treatment. However, it is known that the dental unit water line (DUWL) can become contaminated with biofilm, consisting mainly of heterotrophic bacteria (HB). Recently, the International Organization for Standardization specified the methods for testing DUWL contamination management. On these grounds, a simulator reproducing DUWL was prepared to standardize the examination method of the DUWL contamination. OBJECTIVES: To evaluate the reproducibility of the DUWL simulator, monitor the DUWL contamination states, and test the efficacy of a commercial decontaminant for DUWL. METHODS: The DUWL simulator was assembled by a DCU manufacturing company. The simulator's DUWL was filled with tap water (TW), and left for approximately one year. Neutral electrolyzed water (NEW) was used as a decontaminant for DUWL. Both TW and NEW were passed through DUWL in a timely manner simulating daily dental treatment. Water was sampled from the air turbine hand piece weekly for 4 weeks and used for HB culture. Contamination status was evaluated by measuring bacterial adenosine triphosphate release and by culturing on Reasoner's 2A medium. RESULTS: The DUWL released contaminated water had a bacterial count of over 6 × 10(4) cfu/mL. After passing NEW through DUWL for 1 week, the count drastically decreased to its basal level and remained steady for 4 weeks. However, TW showed no effect on DUWL decontamination throughout the examination periods. CONCLUSIONS: The DUWL simulator could be useful to examine the efficacy of the decontaminant for DUWL and development of new methods in DUWL contamination management.
format Online
Article
Text
id pubmed-7298401
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-72984012020-06-19 Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines Okubo, Keisuke Ito, Takashi Okamoto, Kentaro Yamamoto, Ichiro Mizutani, Hajime Kawata, Yusuke Shiota, Yasuyoshi Ito, Masahiro Nakamura, Shin Tai, Masako Yamamoto, Tadashi Takashiba, Shogo Heliyon Article The prevention of nosocomial infections is an imperative task. The dental chair unit (DCU) is an indispensable device used in dental treatment. However, it is known that the dental unit water line (DUWL) can become contaminated with biofilm, consisting mainly of heterotrophic bacteria (HB). Recently, the International Organization for Standardization specified the methods for testing DUWL contamination management. On these grounds, a simulator reproducing DUWL was prepared to standardize the examination method of the DUWL contamination. OBJECTIVES: To evaluate the reproducibility of the DUWL simulator, monitor the DUWL contamination states, and test the efficacy of a commercial decontaminant for DUWL. METHODS: The DUWL simulator was assembled by a DCU manufacturing company. The simulator's DUWL was filled with tap water (TW), and left for approximately one year. Neutral electrolyzed water (NEW) was used as a decontaminant for DUWL. Both TW and NEW were passed through DUWL in a timely manner simulating daily dental treatment. Water was sampled from the air turbine hand piece weekly for 4 weeks and used for HB culture. Contamination status was evaluated by measuring bacterial adenosine triphosphate release and by culturing on Reasoner's 2A medium. RESULTS: The DUWL released contaminated water had a bacterial count of over 6 × 10(4) cfu/mL. After passing NEW through DUWL for 1 week, the count drastically decreased to its basal level and remained steady for 4 weeks. However, TW showed no effect on DUWL decontamination throughout the examination periods. CONCLUSIONS: The DUWL simulator could be useful to examine the efficacy of the decontaminant for DUWL and development of new methods in DUWL contamination management. Elsevier 2020-06-10 /pmc/articles/PMC7298401/ /pubmed/32566782 http://dx.doi.org/10.1016/j.heliyon.2020.e04132 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Okubo, Keisuke
Ito, Takashi
Okamoto, Kentaro
Yamamoto, Ichiro
Mizutani, Hajime
Kawata, Yusuke
Shiota, Yasuyoshi
Ito, Masahiro
Nakamura, Shin
Tai, Masako
Yamamoto, Tadashi
Takashiba, Shogo
Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
title Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
title_full Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
title_fullStr Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
title_full_unstemmed Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
title_short Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
title_sort evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7298401/
https://www.ncbi.nlm.nih.gov/pubmed/32566782
http://dx.doi.org/10.1016/j.heliyon.2020.e04132
work_keys_str_mv AT okubokeisuke evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT itotakashi evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT okamotokentaro evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT yamamotoichiro evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT mizutanihajime evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT kawatayusuke evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT shiotayasuyoshi evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT itomasahiro evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT nakamurashin evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT taimasako evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT yamamototadashi evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines
AT takashibashogo evaluationofthesimulatorwithautomaticirrigationcontrolsystemdesignedforcountermeasuresofinternalcontaminationindentalunitwaterlines