Cargando…

Transseptal occluder migration after transcatheter atrial septal aneurysm and double secondary septal defect correction: A case report

We present a case of secondary atrial septal defect transcatheter correction attempt in a 72 years old male, complicated by the device migration. The occluder was captured, pulled down to the common femoral artery and retrieved through the arteriotomy site. Second attempt was successfully performed...

Descripción completa

Detalles Bibliográficos
Autores principales: Guryev, Valentin V., Zverev, Dmitriy A., Khilchuk, Anton A., Shcherbak, Sergey G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7298566/
https://www.ncbi.nlm.nih.gov/pubmed/32566068
http://dx.doi.org/10.1016/j.radcr.2020.05.042
Descripción
Sumario:We present a case of secondary atrial septal defect transcatheter correction attempt in a 72 years old male, complicated by the device migration. The occluder was captured, pulled down to the common femoral artery and retrieved through the arteriotomy site. Second attempt was successfully performed using combination of transesophageal echo (TEE) and sizing balloon to accurately measure the defect diameter. This case underscores the importance of TEE ultrasound, sizing balloon, and contrast fluoroscopy combination to achieve accurate device sizing. Our calculation approach significantly increased the success rate of the septal defect closure procedure and potentially reduced the risk of immediate and mid-term complications. Combination of measuring methods should be used in order to accurately assess the device diameter.