Cargando…

Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate

We report wide-field polygon-scanning functional OR-PAM that for the first time achieves 1-MHz A-line rate of oxygen saturation in vivo. We address two technical challenges. The first is a 1-MHz dual-wavelength pulsed laser that has sufficient pulse energy and ultrafast wavelength switching. The sec...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jiangbo, Zhang, Yachao, He, Linyun, Liang, Yizhi, Wang, Lidai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7300162/
https://www.ncbi.nlm.nih.gov/pubmed/32577378
http://dx.doi.org/10.1016/j.pacs.2020.100195
_version_ 1783547530507714560
author Chen, Jiangbo
Zhang, Yachao
He, Linyun
Liang, Yizhi
Wang, Lidai
author_facet Chen, Jiangbo
Zhang, Yachao
He, Linyun
Liang, Yizhi
Wang, Lidai
author_sort Chen, Jiangbo
collection PubMed
description We report wide-field polygon-scanning functional OR-PAM that for the first time achieves 1-MHz A-line rate of oxygen saturation in vivo. We address two technical challenges. The first is a 1-MHz dual-wavelength pulsed laser that has sufficient pulse energy and ultrafast wavelength switching. The second is a polygon-scanning imaging probe that has a fast scanning speed, a large field of view, and great sensitivity. The OR-PAM system offers a B-scan rate of 477.5 Hz in a 12-mm range and a volumetric imaging rate of ∼1 Hz over a 12 × 5 mm(2) scanning area. We image microvasculature and blood oxygen saturation in a 12 × 12 mm(2) scanning area in 5 s. Dynamic imaging of oxygen saturation in the mouse ear is demonstrated to monitor fast response to epinephrine injection. The new wide-field fast functional imaging ability broadens the biomedical application of OR-PAM.
format Online
Article
Text
id pubmed-7300162
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-73001622020-06-22 Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate Chen, Jiangbo Zhang, Yachao He, Linyun Liang, Yizhi Wang, Lidai Photoacoustics Research Article We report wide-field polygon-scanning functional OR-PAM that for the first time achieves 1-MHz A-line rate of oxygen saturation in vivo. We address two technical challenges. The first is a 1-MHz dual-wavelength pulsed laser that has sufficient pulse energy and ultrafast wavelength switching. The second is a polygon-scanning imaging probe that has a fast scanning speed, a large field of view, and great sensitivity. The OR-PAM system offers a B-scan rate of 477.5 Hz in a 12-mm range and a volumetric imaging rate of ∼1 Hz over a 12 × 5 mm(2) scanning area. We image microvasculature and blood oxygen saturation in a 12 × 12 mm(2) scanning area in 5 s. Dynamic imaging of oxygen saturation in the mouse ear is demonstrated to monitor fast response to epinephrine injection. The new wide-field fast functional imaging ability broadens the biomedical application of OR-PAM. Elsevier 2020-06-07 /pmc/articles/PMC7300162/ /pubmed/32577378 http://dx.doi.org/10.1016/j.pacs.2020.100195 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Chen, Jiangbo
Zhang, Yachao
He, Linyun
Liang, Yizhi
Wang, Lidai
Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate
title Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate
title_full Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate
title_fullStr Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate
title_full_unstemmed Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate
title_short Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate
title_sort wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-mhz a-line rate
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7300162/
https://www.ncbi.nlm.nih.gov/pubmed/32577378
http://dx.doi.org/10.1016/j.pacs.2020.100195
work_keys_str_mv AT chenjiangbo widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate
AT zhangyachao widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate
AT helinyun widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate
AT liangyizhi widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate
AT wanglidai widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate