Cargando…
Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate
We report wide-field polygon-scanning functional OR-PAM that for the first time achieves 1-MHz A-line rate of oxygen saturation in vivo. We address two technical challenges. The first is a 1-MHz dual-wavelength pulsed laser that has sufficient pulse energy and ultrafast wavelength switching. The sec...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7300162/ https://www.ncbi.nlm.nih.gov/pubmed/32577378 http://dx.doi.org/10.1016/j.pacs.2020.100195 |
_version_ | 1783547530507714560 |
---|---|
author | Chen, Jiangbo Zhang, Yachao He, Linyun Liang, Yizhi Wang, Lidai |
author_facet | Chen, Jiangbo Zhang, Yachao He, Linyun Liang, Yizhi Wang, Lidai |
author_sort | Chen, Jiangbo |
collection | PubMed |
description | We report wide-field polygon-scanning functional OR-PAM that for the first time achieves 1-MHz A-line rate of oxygen saturation in vivo. We address two technical challenges. The first is a 1-MHz dual-wavelength pulsed laser that has sufficient pulse energy and ultrafast wavelength switching. The second is a polygon-scanning imaging probe that has a fast scanning speed, a large field of view, and great sensitivity. The OR-PAM system offers a B-scan rate of 477.5 Hz in a 12-mm range and a volumetric imaging rate of ∼1 Hz over a 12 × 5 mm(2) scanning area. We image microvasculature and blood oxygen saturation in a 12 × 12 mm(2) scanning area in 5 s. Dynamic imaging of oxygen saturation in the mouse ear is demonstrated to monitor fast response to epinephrine injection. The new wide-field fast functional imaging ability broadens the biomedical application of OR-PAM. |
format | Online Article Text |
id | pubmed-7300162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-73001622020-06-22 Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate Chen, Jiangbo Zhang, Yachao He, Linyun Liang, Yizhi Wang, Lidai Photoacoustics Research Article We report wide-field polygon-scanning functional OR-PAM that for the first time achieves 1-MHz A-line rate of oxygen saturation in vivo. We address two technical challenges. The first is a 1-MHz dual-wavelength pulsed laser that has sufficient pulse energy and ultrafast wavelength switching. The second is a polygon-scanning imaging probe that has a fast scanning speed, a large field of view, and great sensitivity. The OR-PAM system offers a B-scan rate of 477.5 Hz in a 12-mm range and a volumetric imaging rate of ∼1 Hz over a 12 × 5 mm(2) scanning area. We image microvasculature and blood oxygen saturation in a 12 × 12 mm(2) scanning area in 5 s. Dynamic imaging of oxygen saturation in the mouse ear is demonstrated to monitor fast response to epinephrine injection. The new wide-field fast functional imaging ability broadens the biomedical application of OR-PAM. Elsevier 2020-06-07 /pmc/articles/PMC7300162/ /pubmed/32577378 http://dx.doi.org/10.1016/j.pacs.2020.100195 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Chen, Jiangbo Zhang, Yachao He, Linyun Liang, Yizhi Wang, Lidai Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate |
title | Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate |
title_full | Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate |
title_fullStr | Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate |
title_full_unstemmed | Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate |
title_short | Wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-MHz A-line rate |
title_sort | wide-field polygon-scanning photoacoustic microscopy of oxygen saturation at 1-mhz a-line rate |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7300162/ https://www.ncbi.nlm.nih.gov/pubmed/32577378 http://dx.doi.org/10.1016/j.pacs.2020.100195 |
work_keys_str_mv | AT chenjiangbo widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate AT zhangyachao widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate AT helinyun widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate AT liangyizhi widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate AT wanglidai widefieldpolygonscanningphotoacousticmicroscopyofoxygensaturationat1mhzalinerate |