Cargando…

Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study

BACKGROUND: The Polarstem (Smith & Nephew, Baar, Switzerland) is a tapered straight stem, an implant with an excellent survival rate. Although the most recent annual report of the National Joint Registry in the United Kingdom also reports excellent survivorship for the cementless Polarstem, no p...

Descripción completa

Detalles Bibliográficos
Autores principales: Willburger, Roland E., Heukamp, Matthias, Lindenlaub, Philippe, Efe, Turgay, Peterlein, Christian-D., Schüttler, Karl-F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7303481/
https://www.ncbi.nlm.nih.gov/pubmed/32577462
http://dx.doi.org/10.1016/j.artd.2020.01.009
_version_ 1783548067579953152
author Willburger, Roland E.
Heukamp, Matthias
Lindenlaub, Philippe
Efe, Turgay
Peterlein, Christian-D.
Schüttler, Karl-F.
author_facet Willburger, Roland E.
Heukamp, Matthias
Lindenlaub, Philippe
Efe, Turgay
Peterlein, Christian-D.
Schüttler, Karl-F.
author_sort Willburger, Roland E.
collection PubMed
description BACKGROUND: The Polarstem (Smith & Nephew, Baar, Switzerland) is a tapered straight stem, an implant with an excellent survival rate. Although the most recent annual report of the National Joint Registry in the United Kingdom also reports excellent survivorship for the cementless Polarstem, no prospective studies have been published focusing on both its efficacy and clinical performance. Therefore, the present study was designed to prospectively evaluate its functional and radiographic outcomes at midterm. METHODS: This prospective observational study conducted at 3 independent orthopaedic hospitals was designed to collect data in patients undergoing cementless primary total hip arthroplasty (THA). A total of 225 total hip arthroplasties (75 at each site) were performed. The predominant diagnosis was primary osteoarthritis. Anteroposterior and lateral radiographs were obtained at each follow-up (3 months, and 1, 3, and 5 years). Survivorship and the Harris Hip Score (HHS) and Western Ontario and McMaster Universities Index (WOMAC) were calculated. RESULTS: Subjects experienced statistically significant improvements from baseline in mean HHS (48.5 to 88.0, P < .01) and WOMAC scores (58.6 to 9.3, P < .01) at all intervals through 5 years. The stem survivorship was 99.6% at 5 years with stem revision due to any reason. There were no observed cases of mechanical failure of the stem or signs of radiographic loosening. CONCLUSIONS: A revision rate of the femoral stem for any reason of 0.4%, as well as good clinical results based on HHS and WOMAC scores, was noted at 5-year follow-up. Therefore, safety and efficacy of the cementless Polarstem at midterm follow-up is confirmed.
format Online
Article
Text
id pubmed-7303481
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-73034812020-06-22 Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study Willburger, Roland E. Heukamp, Matthias Lindenlaub, Philippe Efe, Turgay Peterlein, Christian-D. Schüttler, Karl-F. Arthroplast Today Original Research BACKGROUND: The Polarstem (Smith & Nephew, Baar, Switzerland) is a tapered straight stem, an implant with an excellent survival rate. Although the most recent annual report of the National Joint Registry in the United Kingdom also reports excellent survivorship for the cementless Polarstem, no prospective studies have been published focusing on both its efficacy and clinical performance. Therefore, the present study was designed to prospectively evaluate its functional and radiographic outcomes at midterm. METHODS: This prospective observational study conducted at 3 independent orthopaedic hospitals was designed to collect data in patients undergoing cementless primary total hip arthroplasty (THA). A total of 225 total hip arthroplasties (75 at each site) were performed. The predominant diagnosis was primary osteoarthritis. Anteroposterior and lateral radiographs were obtained at each follow-up (3 months, and 1, 3, and 5 years). Survivorship and the Harris Hip Score (HHS) and Western Ontario and McMaster Universities Index (WOMAC) were calculated. RESULTS: Subjects experienced statistically significant improvements from baseline in mean HHS (48.5 to 88.0, P < .01) and WOMAC scores (58.6 to 9.3, P < .01) at all intervals through 5 years. The stem survivorship was 99.6% at 5 years with stem revision due to any reason. There were no observed cases of mechanical failure of the stem or signs of radiographic loosening. CONCLUSIONS: A revision rate of the femoral stem for any reason of 0.4%, as well as good clinical results based on HHS and WOMAC scores, was noted at 5-year follow-up. Therefore, safety and efficacy of the cementless Polarstem at midterm follow-up is confirmed. Elsevier 2020-03-31 /pmc/articles/PMC7303481/ /pubmed/32577462 http://dx.doi.org/10.1016/j.artd.2020.01.009 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Willburger, Roland E.
Heukamp, Matthias
Lindenlaub, Philippe
Efe, Turgay
Peterlein, Christian-D.
Schüttler, Karl-F.
Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study
title Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study
title_full Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study
title_fullStr Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study
title_full_unstemmed Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study
title_short Excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study
title_sort excellent midterm survival and functional outcomes of a fully hydroxyapatite-coated cementless stem: first results of a prospective multicenter study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7303481/
https://www.ncbi.nlm.nih.gov/pubmed/32577462
http://dx.doi.org/10.1016/j.artd.2020.01.009
work_keys_str_mv AT willburgerrolande excellentmidtermsurvivalandfunctionaloutcomesofafullyhydroxyapatitecoatedcementlessstemfirstresultsofaprospectivemulticenterstudy
AT heukampmatthias excellentmidtermsurvivalandfunctionaloutcomesofafullyhydroxyapatitecoatedcementlessstemfirstresultsofaprospectivemulticenterstudy
AT lindenlaubphilippe excellentmidtermsurvivalandfunctionaloutcomesofafullyhydroxyapatitecoatedcementlessstemfirstresultsofaprospectivemulticenterstudy
AT efeturgay excellentmidtermsurvivalandfunctionaloutcomesofafullyhydroxyapatitecoatedcementlessstemfirstresultsofaprospectivemulticenterstudy
AT peterleinchristiand excellentmidtermsurvivalandfunctionaloutcomesofafullyhydroxyapatitecoatedcementlessstemfirstresultsofaprospectivemulticenterstudy
AT schuttlerkarlf excellentmidtermsurvivalandfunctionaloutcomesofafullyhydroxyapatitecoatedcementlessstemfirstresultsofaprospectivemulticenterstudy