A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants

BACKGROUND: The purpose of our study was to compare 2 commonly used highly successful cruciate-retaining knee designs on the basis of patient-reported outcome measures (PROMs), range of motion (ROM), and anterior knee pain (AKP) at a minimum follow-up of 5 years. METHODS: A cohort of 65 patients und...

Descripción completa

Detalles Bibliográficos
Autores principales: Rajgopal, Ashok, Aggarwal, Kalpana, Kumar, Sumit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7303521/
https://www.ncbi.nlm.nih.gov/pubmed/32577480
http://dx.doi.org/10.1016/j.artd.2020.05.009
_version_ 1783548075925569536
author Rajgopal, Ashok
Aggarwal, Kalpana
Kumar, Sumit
author_facet Rajgopal, Ashok
Aggarwal, Kalpana
Kumar, Sumit
author_sort Rajgopal, Ashok
collection PubMed
description BACKGROUND: The purpose of our study was to compare 2 commonly used highly successful cruciate-retaining knee designs on the basis of patient-reported outcome measures (PROMs), range of motion (ROM), and anterior knee pain (AKP) at a minimum follow-up of 5 years. METHODS: A cohort of 65 patients underwent unilateral total knee arthroplasty, from January 2013 to December 2013, using NexGen Cruciate Retaining (Zimmer Biomet, Warsaw, IN), a nonmorphogenic knee (NMK) system. They were subsequently operated upon for the contralateral knee using Persona Cruciate Retaining (Zimmer Biomet, Warsaw, IN), a morphogenic knee (MK) system between January 2014 and June 2014. Of the 65 patients, 63 participated in this study. All the patients were compared preoperatively and postoperatively on the basis of PROMs, ROM, and AKP. RESULTS: On the basis of PROMs, ROM, and AKP, there was a statistically significant difference between the 2 groups favoring the MK group, with an ROM of 126.14° in the MK group as compared with 120.76° in the NMK group and P value of <.01. CONCLUSIONS: PROMs, ROM, and AKP improved significantly over time after total knee arthroplasty using both MK and NMK implants; however, the outcomes of the former were better than those of the latter, although this difference was not clinically significant.
format Online
Article
Text
id pubmed-7303521
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-73035212020-06-22 A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants Rajgopal, Ashok Aggarwal, Kalpana Kumar, Sumit Arthroplast Today Original Research BACKGROUND: The purpose of our study was to compare 2 commonly used highly successful cruciate-retaining knee designs on the basis of patient-reported outcome measures (PROMs), range of motion (ROM), and anterior knee pain (AKP) at a minimum follow-up of 5 years. METHODS: A cohort of 65 patients underwent unilateral total knee arthroplasty, from January 2013 to December 2013, using NexGen Cruciate Retaining (Zimmer Biomet, Warsaw, IN), a nonmorphogenic knee (NMK) system. They were subsequently operated upon for the contralateral knee using Persona Cruciate Retaining (Zimmer Biomet, Warsaw, IN), a morphogenic knee (MK) system between January 2014 and June 2014. Of the 65 patients, 63 participated in this study. All the patients were compared preoperatively and postoperatively on the basis of PROMs, ROM, and AKP. RESULTS: On the basis of PROMs, ROM, and AKP, there was a statistically significant difference between the 2 groups favoring the MK group, with an ROM of 126.14° in the MK group as compared with 120.76° in the NMK group and P value of <.01. CONCLUSIONS: PROMs, ROM, and AKP improved significantly over time after total knee arthroplasty using both MK and NMK implants; however, the outcomes of the former were better than those of the latter, although this difference was not clinically significant. Elsevier 2020-06-16 /pmc/articles/PMC7303521/ /pubmed/32577480 http://dx.doi.org/10.1016/j.artd.2020.05.009 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Rajgopal, Ashok
Aggarwal, Kalpana
Kumar, Sumit
A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants
title A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants
title_full A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants
title_fullStr A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants
title_full_unstemmed A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants
title_short A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants
title_sort five-year comparative functional and clinical evaluation of two contemporary cruciate-retaining knee implants
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7303521/
https://www.ncbi.nlm.nih.gov/pubmed/32577480
http://dx.doi.org/10.1016/j.artd.2020.05.009
work_keys_str_mv AT rajgopalashok afiveyearcomparativefunctionalandclinicalevaluationoftwocontemporarycruciateretainingkneeimplants
AT aggarwalkalpana afiveyearcomparativefunctionalandclinicalevaluationoftwocontemporarycruciateretainingkneeimplants
AT kumarsumit afiveyearcomparativefunctionalandclinicalevaluationoftwocontemporarycruciateretainingkneeimplants
AT rajgopalashok fiveyearcomparativefunctionalandclinicalevaluationoftwocontemporarycruciateretainingkneeimplants
AT aggarwalkalpana fiveyearcomparativefunctionalandclinicalevaluationoftwocontemporarycruciateretainingkneeimplants
AT kumarsumit fiveyearcomparativefunctionalandclinicalevaluationoftwocontemporarycruciateretainingkneeimplants