Cargando…

Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience

BACKGROUND: En-bloc resection of large, flat dysplastic mucosal lesions of the luminal GI tract can be challenging. In order to improve the efficacy of resection for lesions ≥2 cm and to optimize R0 resection rates of lesions suspected of harboring high-grade dysplasia or early adenocarcinoma, a nov...

Descripción completa

Detalles Bibliográficos
Autores principales: Sportes, A., CFM, Jung, Gromski, M. A., Koehler, P., Seif Amir Hosseini, A., Kauffmann, P., Ellenrieder, V., Wedi, E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7304141/
https://www.ncbi.nlm.nih.gov/pubmed/32560696
http://dx.doi.org/10.1186/s12876-020-01344-6
_version_ 1783548206218477568
author Sportes, A.
CFM, Jung
Gromski, M. A.
Koehler, P.
Seif Amir Hosseini, A.
Kauffmann, P.
Ellenrieder, V.
Wedi, E.
author_facet Sportes, A.
CFM, Jung
Gromski, M. A.
Koehler, P.
Seif Amir Hosseini, A.
Kauffmann, P.
Ellenrieder, V.
Wedi, E.
author_sort Sportes, A.
collection PubMed
description BACKGROUND: En-bloc resection of large, flat dysplastic mucosal lesions of the luminal GI tract can be challenging. In order to improve the efficacy of resection for lesions ≥2 cm and to optimize R0 resection rates of lesions suspected of harboring high-grade dysplasia or early adenocarcinoma, a novel grasp and snare EMR technique utilizing a novel over the scope additional accessory channel, termed EMR Plus (EMR+), was developed. The aim of this pilot study is to describe the early safety and efficacy data from the first in human clinical cases. METHODS: A novel external over-the-scope additional working channel (AWC) (Ovesco, Tuebingen, Germany) was utilized for the EMR+ procedure, allowing a second endoscopic device to be used through the AWC while using otherwise standard endoscopic equipment. The EMR+ technique allows tissue retraction and a degree of triangulation during endoscopic resection. We performed EMR+ procedure in 6 patients between 02/2018–12/2018 for lesions in the upper and lower GI tract. RESULTS: The EMR+ technique utilizing the AWC was performed successfully in 6 resection procedures of the upper and/or lower GI tract in 6 patients in 2 endoscopy centers. All resections were performed successfully with the EMR+ technique, all achieving an R0 resection. No severe adverse events occurred in any of the procedures. CONCLUSIONS: The EMR+ technique, utilizing an additional working channel, had an acceptable safety and efficacy profile in this preliminary study demonstrating it’s first use in humans. This technique may allow an additional option to providers to remove complex, large mucosal-based lesions in the GI tract using standard endoscopic equipment and a novel AWC device.
format Online
Article
Text
id pubmed-7304141
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73041412020-06-22 Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience Sportes, A. CFM, Jung Gromski, M. A. Koehler, P. Seif Amir Hosseini, A. Kauffmann, P. Ellenrieder, V. Wedi, E. BMC Gastroenterol Technical Advance BACKGROUND: En-bloc resection of large, flat dysplastic mucosal lesions of the luminal GI tract can be challenging. In order to improve the efficacy of resection for lesions ≥2 cm and to optimize R0 resection rates of lesions suspected of harboring high-grade dysplasia or early adenocarcinoma, a novel grasp and snare EMR technique utilizing a novel over the scope additional accessory channel, termed EMR Plus (EMR+), was developed. The aim of this pilot study is to describe the early safety and efficacy data from the first in human clinical cases. METHODS: A novel external over-the-scope additional working channel (AWC) (Ovesco, Tuebingen, Germany) was utilized for the EMR+ procedure, allowing a second endoscopic device to be used through the AWC while using otherwise standard endoscopic equipment. The EMR+ technique allows tissue retraction and a degree of triangulation during endoscopic resection. We performed EMR+ procedure in 6 patients between 02/2018–12/2018 for lesions in the upper and lower GI tract. RESULTS: The EMR+ technique utilizing the AWC was performed successfully in 6 resection procedures of the upper and/or lower GI tract in 6 patients in 2 endoscopy centers. All resections were performed successfully with the EMR+ technique, all achieving an R0 resection. No severe adverse events occurred in any of the procedures. CONCLUSIONS: The EMR+ technique, utilizing an additional working channel, had an acceptable safety and efficacy profile in this preliminary study demonstrating it’s first use in humans. This technique may allow an additional option to providers to remove complex, large mucosal-based lesions in the GI tract using standard endoscopic equipment and a novel AWC device. BioMed Central 2020-06-19 /pmc/articles/PMC7304141/ /pubmed/32560696 http://dx.doi.org/10.1186/s12876-020-01344-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Technical Advance
Sportes, A.
CFM, Jung
Gromski, M. A.
Koehler, P.
Seif Amir Hosseini, A.
Kauffmann, P.
Ellenrieder, V.
Wedi, E.
Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience
title Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience
title_full Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience
title_fullStr Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience
title_full_unstemmed Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience
title_short Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience
title_sort novel modified endoscopic mucosal resection of large gi lesions (> 20 mm) using an external additional working channel (awc) may improve r0 resection rate: initial clinical experience
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7304141/
https://www.ncbi.nlm.nih.gov/pubmed/32560696
http://dx.doi.org/10.1186/s12876-020-01344-6
work_keys_str_mv AT sportesa novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience
AT cfmjung novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience
AT gromskima novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience
AT koehlerp novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience
AT seifamirhosseinia novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience
AT kauffmannp novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience
AT ellenriederv novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience
AT wedie novelmodifiedendoscopicmucosalresectionoflargegilesions20mmusinganexternaladditionalworkingchannelawcmayimprover0resectionrateinitialclinicalexperience