Optimum Sample Thickness for Trace Analyte Detection with Field-Resolved Infrared Spectroscopy
[Image: see text] The strong absorption of liquid water in the infrared (IR) molecular fingerprint region constitutes a challenge for applications of vibrational spectroscopy in chemistry, biology, and medicine. While high-power IR laser sources enable the penetration of ever thicker aqueous samples...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American
Chemical
Society
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7304664/ https://www.ncbi.nlm.nih.gov/pubmed/32352273 http://dx.doi.org/10.1021/acs.analchem.9b05744 |
_version_ | 1783548299230314496 |
---|---|
author | Huber, Marinus Trubetskov, Michael Hussain, Syed A. Schweinberger, Wolfgang Hofer, Christina Pupeza, Ioachim |
author_facet | Huber, Marinus Trubetskov, Michael Hussain, Syed A. Schweinberger, Wolfgang Hofer, Christina Pupeza, Ioachim |
author_sort | Huber, Marinus |
collection | PubMed |
description | [Image: see text] The strong absorption of liquid water in the infrared (IR) molecular fingerprint region constitutes a challenge for applications of vibrational spectroscopy in chemistry, biology, and medicine. While high-power IR laser sources enable the penetration of ever thicker aqueous samples, thereby mitigating the detrimental effects of strong attenuation on detection sensitivity, a basic advantage of heterodyne-measurement-based methods has—to the best of our knowledge—not been harnessed in broadband IR measurements to date. Here, employing field-resolved spectroscopy (FRS), we demonstrate in theory and experiment fundamental advantages of techniques whose signal-to-noise ratio (SNR) scales linearly with the electric field over those whose SNR scales linearly with radiation intensity, including conventional Fourier-transform infrared (FTIR) and direct absorption spectroscopy. Field-scaling brings about two major improvements. First, it squares the measurement dynamic range. Second, we show that the optimum interaction length with samples for SNR-maximized measurements is twice the value usually considered to be optimum for FTIR devices. In order to take full advantage of these properties, the measurement must not be significantly affected by technical noise, such as intensity fluctuations, which are common for high-power sources. Recently, it has been shown that subcycle, nonlinear gating of the molecular fingerprint signal renders FRS robust against intensity noise. Here, we quantitatively demonstrate this advantage of FRS for thick aqueous samples. We report sub-μg/mL detection sensitivities for transmission path lengths up to 80 μm and a limit of detection in the lower μg/mL range for transmission paths as long as 200 μm. |
format | Online Article Text |
id | pubmed-7304664 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | American
Chemical
Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-73046642020-06-22 Optimum Sample Thickness for Trace Analyte Detection with Field-Resolved Infrared Spectroscopy Huber, Marinus Trubetskov, Michael Hussain, Syed A. Schweinberger, Wolfgang Hofer, Christina Pupeza, Ioachim Anal Chem [Image: see text] The strong absorption of liquid water in the infrared (IR) molecular fingerprint region constitutes a challenge for applications of vibrational spectroscopy in chemistry, biology, and medicine. While high-power IR laser sources enable the penetration of ever thicker aqueous samples, thereby mitigating the detrimental effects of strong attenuation on detection sensitivity, a basic advantage of heterodyne-measurement-based methods has—to the best of our knowledge—not been harnessed in broadband IR measurements to date. Here, employing field-resolved spectroscopy (FRS), we demonstrate in theory and experiment fundamental advantages of techniques whose signal-to-noise ratio (SNR) scales linearly with the electric field over those whose SNR scales linearly with radiation intensity, including conventional Fourier-transform infrared (FTIR) and direct absorption spectroscopy. Field-scaling brings about two major improvements. First, it squares the measurement dynamic range. Second, we show that the optimum interaction length with samples for SNR-maximized measurements is twice the value usually considered to be optimum for FTIR devices. In order to take full advantage of these properties, the measurement must not be significantly affected by technical noise, such as intensity fluctuations, which are common for high-power sources. Recently, it has been shown that subcycle, nonlinear gating of the molecular fingerprint signal renders FRS robust against intensity noise. Here, we quantitatively demonstrate this advantage of FRS for thick aqueous samples. We report sub-μg/mL detection sensitivities for transmission path lengths up to 80 μm and a limit of detection in the lower μg/mL range for transmission paths as long as 200 μm. American Chemical Society 2020-04-30 2020-06-02 /pmc/articles/PMC7304664/ /pubmed/32352273 http://dx.doi.org/10.1021/acs.analchem.9b05744 Text en Copyright © 2020 American Chemical Society This is an open access article published under a Creative Commons Attribution (CC-BY) License (http://pubs.acs.org/page/policy/authorchoice_ccby_termsofuse.html) , which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited. |
spellingShingle | Huber, Marinus Trubetskov, Michael Hussain, Syed A. Schweinberger, Wolfgang Hofer, Christina Pupeza, Ioachim Optimum Sample Thickness for Trace Analyte Detection with Field-Resolved Infrared Spectroscopy |
title | Optimum Sample Thickness for Trace Analyte Detection
with Field-Resolved Infrared Spectroscopy |
title_full | Optimum Sample Thickness for Trace Analyte Detection
with Field-Resolved Infrared Spectroscopy |
title_fullStr | Optimum Sample Thickness for Trace Analyte Detection
with Field-Resolved Infrared Spectroscopy |
title_full_unstemmed | Optimum Sample Thickness for Trace Analyte Detection
with Field-Resolved Infrared Spectroscopy |
title_short | Optimum Sample Thickness for Trace Analyte Detection
with Field-Resolved Infrared Spectroscopy |
title_sort | optimum sample thickness for trace analyte detection
with field-resolved infrared spectroscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7304664/ https://www.ncbi.nlm.nih.gov/pubmed/32352273 http://dx.doi.org/10.1021/acs.analchem.9b05744 |
work_keys_str_mv | AT hubermarinus optimumsamplethicknessfortraceanalytedetectionwithfieldresolvedinfraredspectroscopy AT trubetskovmichael optimumsamplethicknessfortraceanalytedetectionwithfieldresolvedinfraredspectroscopy AT hussainsyeda optimumsamplethicknessfortraceanalytedetectionwithfieldresolvedinfraredspectroscopy AT schweinbergerwolfgang optimumsamplethicknessfortraceanalytedetectionwithfieldresolvedinfraredspectroscopy AT hoferchristina optimumsamplethicknessfortraceanalytedetectionwithfieldresolvedinfraredspectroscopy AT pupezaioachim optimumsamplethicknessfortraceanalytedetectionwithfieldresolvedinfraredspectroscopy |