Cargando…
Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients
PURPOSE: To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in ima...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7305089/ https://www.ncbi.nlm.nih.gov/pubmed/32157345 http://dx.doi.org/10.1007/s00066-020-01596-x |
_version_ | 1783548385024802816 |
---|---|
author | Böckelmann, Felix Putz, Florian Kallis, Karoline Lettmaier, Sebastian Fietkau, Rainer Bert, Christoph |
author_facet | Böckelmann, Felix Putz, Florian Kallis, Karoline Lettmaier, Sebastian Fietkau, Rainer Bert, Christoph |
author_sort | Böckelmann, Felix |
collection | PubMed |
description | PURPOSE: To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in image-guided radiotherapy for prostate cancer (PCa). MATERIALS AND METHODS: A CTV (clinical target volume)-to-PTV margin ranging from 15 mm in LR (left-right) and SI (superior-inferior) and 5–10 mm in AP (anterior-posterior) direction was applied to all patients. The dosimetric influence of this margin was retrospectively calculated by analysing systematic and random components of inter and intra errors of 31 consecutive intermediate- and high-risk localized PCa patients using daily cone beam computed tomography and kV/kV (kilo-Voltage) imaging. For each patient inter variation was assessed by observing the first 4 treatment days, which led to an offline ART-based treatment plan in case of larger variations. RESULTS: Systematic inter uncertainties were larger (1.12 in LR, 2.28 in SI and 1.48 mm in AP) than intra systematic errors (0.44 in LR, 0.69 in SI and 0.80 mm in AP). Same findings for the random error in SI direction with 3.19 (inter) and 2.30 mm (intra), whereas in LR and AP results were alike with 1.89 (inter) and 1.91 mm (intra) and 2.10 (inter) and 2.27 mm (intra), respectively. The calculated margin revealed dimensions of 4–5 mm in LR, 8–9 mm in SI and 6–7 mm in AP direction. Treatment plans which had to be adapted showed smaller variations with 1.12 (LR) and 1.72 mm (SI) for Σ and 4.17 (LR) and 3.75 mm (SI) for σ compared to initial plans with 1.77 and 2.62 mm for Σ and 4.46 and 5.39 mm for σ in LR and SI, respectively. CONCLUSION: The currently clinically used margin of 15 mm in LR and SI and 5–10 mm in AP direction includes inter and intra uncertainties. The results show that offline ART is feasible which becomes a necessity with further reductions in PTV margins. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00066-020-01596-x) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-7305089 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-73050892020-06-22 Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients Böckelmann, Felix Putz, Florian Kallis, Karoline Lettmaier, Sebastian Fietkau, Rainer Bert, Christoph Strahlenther Onkol Original Article PURPOSE: To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in image-guided radiotherapy for prostate cancer (PCa). MATERIALS AND METHODS: A CTV (clinical target volume)-to-PTV margin ranging from 15 mm in LR (left-right) and SI (superior-inferior) and 5–10 mm in AP (anterior-posterior) direction was applied to all patients. The dosimetric influence of this margin was retrospectively calculated by analysing systematic and random components of inter and intra errors of 31 consecutive intermediate- and high-risk localized PCa patients using daily cone beam computed tomography and kV/kV (kilo-Voltage) imaging. For each patient inter variation was assessed by observing the first 4 treatment days, which led to an offline ART-based treatment plan in case of larger variations. RESULTS: Systematic inter uncertainties were larger (1.12 in LR, 2.28 in SI and 1.48 mm in AP) than intra systematic errors (0.44 in LR, 0.69 in SI and 0.80 mm in AP). Same findings for the random error in SI direction with 3.19 (inter) and 2.30 mm (intra), whereas in LR and AP results were alike with 1.89 (inter) and 1.91 mm (intra) and 2.10 (inter) and 2.27 mm (intra), respectively. The calculated margin revealed dimensions of 4–5 mm in LR, 8–9 mm in SI and 6–7 mm in AP direction. Treatment plans which had to be adapted showed smaller variations with 1.12 (LR) and 1.72 mm (SI) for Σ and 4.17 (LR) and 3.75 mm (SI) for σ compared to initial plans with 1.77 and 2.62 mm for Σ and 4.46 and 5.39 mm for σ in LR and SI, respectively. CONCLUSION: The currently clinically used margin of 15 mm in LR and SI and 5–10 mm in AP direction includes inter and intra uncertainties. The results show that offline ART is feasible which becomes a necessity with further reductions in PTV margins. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00066-020-01596-x) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-03-10 2020 /pmc/articles/PMC7305089/ /pubmed/32157345 http://dx.doi.org/10.1007/s00066-020-01596-x Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Article Böckelmann, Felix Putz, Florian Kallis, Karoline Lettmaier, Sebastian Fietkau, Rainer Bert, Christoph Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients |
title | Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients |
title_full | Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients |
title_fullStr | Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients |
title_full_unstemmed | Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients |
title_short | Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients |
title_sort | adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7305089/ https://www.ncbi.nlm.nih.gov/pubmed/32157345 http://dx.doi.org/10.1007/s00066-020-01596-x |
work_keys_str_mv | AT bockelmannfelix adaptiveradiotherapyandthedosimetricimpactofinterandintrafractionalmotionontheplanningtargetvolumeforprostatecancerpatients AT putzflorian adaptiveradiotherapyandthedosimetricimpactofinterandintrafractionalmotionontheplanningtargetvolumeforprostatecancerpatients AT kalliskaroline adaptiveradiotherapyandthedosimetricimpactofinterandintrafractionalmotionontheplanningtargetvolumeforprostatecancerpatients AT lettmaiersebastian adaptiveradiotherapyandthedosimetricimpactofinterandintrafractionalmotionontheplanningtargetvolumeforprostatecancerpatients AT fietkaurainer adaptiveradiotherapyandthedosimetricimpactofinterandintrafractionalmotionontheplanningtargetvolumeforprostatecancerpatients AT bertchristoph adaptiveradiotherapyandthedosimetricimpactofinterandintrafractionalmotionontheplanningtargetvolumeforprostatecancerpatients |