Cargando…

Functionality-packed additively manufactured porous titanium implants

The holy grail of orthopedic implant design is to ward off both aseptic and septic loosening for long enough that the implant outlives the patient. Questing this holy grail is feasible only if orthopedic biomaterials possess a long list of functionalities that enable them to discharge the onerous ta...

Descripción completa

Detalles Bibliográficos
Autores principales: van Hengel, I.A.J., Gelderman, F.S.A., Athanasiadis, S., Minneboo, M., Weinans, H., Fluit, A.C., van der Eerden, B.C.J., Fratila-Apachitei, L.E., Apachitei, I., Zadpoor, A.A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7305382/
https://www.ncbi.nlm.nih.gov/pubmed/32577614
http://dx.doi.org/10.1016/j.mtbio.2020.100060
_version_ 1783548448639811584
author van Hengel, I.A.J.
Gelderman, F.S.A.
Athanasiadis, S.
Minneboo, M.
Weinans, H.
Fluit, A.C.
van der Eerden, B.C.J.
Fratila-Apachitei, L.E.
Apachitei, I.
Zadpoor, A.A.
author_facet van Hengel, I.A.J.
Gelderman, F.S.A.
Athanasiadis, S.
Minneboo, M.
Weinans, H.
Fluit, A.C.
van der Eerden, B.C.J.
Fratila-Apachitei, L.E.
Apachitei, I.
Zadpoor, A.A.
author_sort van Hengel, I.A.J.
collection PubMed
description The holy grail of orthopedic implant design is to ward off both aseptic and septic loosening for long enough that the implant outlives the patient. Questing this holy grail is feasible only if orthopedic biomaterials possess a long list of functionalities that enable them to discharge the onerous task of permanently replacing the native bone tissue. Here, we present a rationally designed and additive manufacturing (AM) topologically ordered porous metallic biomaterial that is made from Ti-6Al-4V using selective laser melting and packs most (if not all) of the required functionalities into a single implant. In addition to presenting a fully interconnected porous structure and form-freedom that enables realization of patient-specific implants, the biomaterials developed here were biofunctionalized using plasma electrolytic oxidation to locally release both osteogenic (i.e. strontium) and antibacterial (i.e. silver ions) agents. The same single-step biofunctionalization process also incorporated hydroxyapatite into the surface of the implants. Our measurements verified the continued release of both types of active agents up to 28 days. Assessment of the antibacterial activity in vitro and in an ex vivo murine model demonstrated extraordinarily high levels of bactericidal effects against a highly virulent and multidrug-resistant Staphylococcus aureus strain (i.e. USA300) with total eradication of both planktonic and adherent bacteria. This strong antibacterial behavior was combined with a significantly enhanced osteogenic behavior, as evidenced by significantly higher levels of alkaline phosphatase (ALP) activity compared with non-biofunctionalized implants. Finally, we discovered synergistic antibacterial behavior between strontium and silver ions, meaning that 4–32 folds lower concentrations of silver ions were required to achieve growth inhibition and total killing of bacteria. The functionality-packed biomaterial presented here demonstrates a unique combination of functionalities that make it an advanced prototype of future orthopedic biomaterials where implants will outlive patients.
format Online
Article
Text
id pubmed-7305382
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-73053822020-06-22 Functionality-packed additively manufactured porous titanium implants van Hengel, I.A.J. Gelderman, F.S.A. Athanasiadis, S. Minneboo, M. Weinans, H. Fluit, A.C. van der Eerden, B.C.J. Fratila-Apachitei, L.E. Apachitei, I. Zadpoor, A.A. Mater Today Bio Full Length Article The holy grail of orthopedic implant design is to ward off both aseptic and septic loosening for long enough that the implant outlives the patient. Questing this holy grail is feasible only if orthopedic biomaterials possess a long list of functionalities that enable them to discharge the onerous task of permanently replacing the native bone tissue. Here, we present a rationally designed and additive manufacturing (AM) topologically ordered porous metallic biomaterial that is made from Ti-6Al-4V using selective laser melting and packs most (if not all) of the required functionalities into a single implant. In addition to presenting a fully interconnected porous structure and form-freedom that enables realization of patient-specific implants, the biomaterials developed here were biofunctionalized using plasma electrolytic oxidation to locally release both osteogenic (i.e. strontium) and antibacterial (i.e. silver ions) agents. The same single-step biofunctionalization process also incorporated hydroxyapatite into the surface of the implants. Our measurements verified the continued release of both types of active agents up to 28 days. Assessment of the antibacterial activity in vitro and in an ex vivo murine model demonstrated extraordinarily high levels of bactericidal effects against a highly virulent and multidrug-resistant Staphylococcus aureus strain (i.e. USA300) with total eradication of both planktonic and adherent bacteria. This strong antibacterial behavior was combined with a significantly enhanced osteogenic behavior, as evidenced by significantly higher levels of alkaline phosphatase (ALP) activity compared with non-biofunctionalized implants. Finally, we discovered synergistic antibacterial behavior between strontium and silver ions, meaning that 4–32 folds lower concentrations of silver ions were required to achieve growth inhibition and total killing of bacteria. The functionality-packed biomaterial presented here demonstrates a unique combination of functionalities that make it an advanced prototype of future orthopedic biomaterials where implants will outlive patients. Elsevier 2020-06-03 /pmc/articles/PMC7305382/ /pubmed/32577614 http://dx.doi.org/10.1016/j.mtbio.2020.100060 Text en © 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Full Length Article
van Hengel, I.A.J.
Gelderman, F.S.A.
Athanasiadis, S.
Minneboo, M.
Weinans, H.
Fluit, A.C.
van der Eerden, B.C.J.
Fratila-Apachitei, L.E.
Apachitei, I.
Zadpoor, A.A.
Functionality-packed additively manufactured porous titanium implants
title Functionality-packed additively manufactured porous titanium implants
title_full Functionality-packed additively manufactured porous titanium implants
title_fullStr Functionality-packed additively manufactured porous titanium implants
title_full_unstemmed Functionality-packed additively manufactured porous titanium implants
title_short Functionality-packed additively manufactured porous titanium implants
title_sort functionality-packed additively manufactured porous titanium implants
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7305382/
https://www.ncbi.nlm.nih.gov/pubmed/32577614
http://dx.doi.org/10.1016/j.mtbio.2020.100060
work_keys_str_mv AT vanhengeliaj functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT geldermanfsa functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT athanasiadiss functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT minneboom functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT weinansh functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT fluitac functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT vandereerdenbcj functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT fratilaapachiteile functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT apachiteii functionalitypackedadditivelymanufacturedporoustitaniumimplants
AT zadpooraa functionalitypackedadditivelymanufacturedporoustitaniumimplants