Dataset of a vanadium redox flow battery 10 membrane-electrode assembly stack

This paper contains a vanadium redox flow battery stack with an electrode surface area 40 cm(2) test data. The aim of the study was to characterize the performance of the stack of the original design. The dataset include three series of galvanostatic charge-discharge cycling in the potential region...

Descripción completa

Detalles Bibliográficos
Autores principales: Glazkov, Artem T., Antipov, Anatoly E., Konev, Dmitry V., Pichugov, Roman D., Petrov, Mikhail M., Kartashova, Natalya V., Loktionov, Pavel A., Averina, Julia M., Plotko, Ivan I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7306588/
https://www.ncbi.nlm.nih.gov/pubmed/32596430
http://dx.doi.org/10.1016/j.dib.2020.105840
Descripción
Sumario:This paper contains a vanadium redox flow battery stack with an electrode surface area 40 cm(2) test data. The aim of the study was to characterize the performance of the stack of the original design. The dataset include three series of galvanostatic charge-discharge cycling in the potential region 8–16 V with current densities 75, 150 and 200 mA/cm(2) for 100 cycles. Coulomb, voltaic, energy efficiencies and capacity utilization coefficient are also provided for all three series.