Cargando…

Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability

Background Adolescent idiopathic scoliosis (AIS) is a potentially progressive deformity, and early detection is crucial for timely intervention. However, the methods and criteria justifying screening for pediatric scoliosis remain controversial. We have, therefore, independently developed a Digital...

Descripción completa

Detalles Bibliográficos
Autores principales: Sato, Tatsuya, Yonezawa, Ikuho, Akimoto, Toshinari, Nobuyuki, Terada, Shimamura, Yukitoshi, Muto, Osamu, Suzuki, Teppei, Momomura, Rei, Uno, Koki, Yamazaki, Ken, Fujiwara, Kenta, Misawa, Akiko, Kaneko, Kazuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7306634/
https://www.ncbi.nlm.nih.gov/pubmed/32582490
http://dx.doi.org/10.7759/cureus.8229
_version_ 1783548694333751296
author Sato, Tatsuya
Yonezawa, Ikuho
Akimoto, Toshinari
Nobuyuki, Terada
Shimamura, Yukitoshi
Muto, Osamu
Suzuki, Teppei
Momomura, Rei
Uno, Koki
Yamazaki, Ken
Fujiwara, Kenta
Misawa, Akiko
Kaneko, Kazuo
author_facet Sato, Tatsuya
Yonezawa, Ikuho
Akimoto, Toshinari
Nobuyuki, Terada
Shimamura, Yukitoshi
Muto, Osamu
Suzuki, Teppei
Momomura, Rei
Uno, Koki
Yamazaki, Ken
Fujiwara, Kenta
Misawa, Akiko
Kaneko, Kazuo
author_sort Sato, Tatsuya
collection PubMed
description Background Adolescent idiopathic scoliosis (AIS) is a potentially progressive deformity, and early detection is crucial for timely intervention. However, the methods and criteria justifying screening for pediatric scoliosis remain controversial. We have, therefore, independently developed a Digital Moiré (DM) as a tool for scoliosis screening. The purpose of this study was to assess the usefulness of DM for scoliosis screening. Methods From March 2016 to March 2017, 126 patients (18 boys, 108 girls, mean age: 13.2 ± 2.2 years) with AIS underwent radiographic imaging of their whole spine. We tested the accuracy and reliability of DM by categorizing the examination results as Class 0 (no abnormality), Class 1 (return visit in one year), and Class 2 (further examination needed) and determined the distribution of the population by Cobb angle. The intra/inter-rater reliability and receiver operating characteristic (ROC) analyses were used to categorize the patients with positive findings into Class 1 or 2. Results Regarding the population distribution per Cobb angle in each of the distributions, 11 patients (8.7%) were Class 0, of which nine and two patients had Cobb angle ≤ 10 ° and > 10 °, respectively. There were 20 (15.9% ) Class 1 cases, of which 17 and three had Cobb angle ≤ 10 ° and > 10 °, respectively. Of the 95 (75.4%) Class 2 cases, five and 90 had a Cobb angle of ≤ 10 ° and > 10 °, respectively. The receiver operating characteristic (ROC) analysis of patients with positive findings showed that the area under the curve (AUC), sensitivity, specificity, and false-positive rate were 0.76, 0.98, 0.53, and 0.47, respectively, when predicting Cobb angle > 10°. Intra-rater and inter-rater reliability were 0.73 and 0.70, respectively. Conclusions This study demonstrated the usefulness of DM for determining whether a child with AIS requires a follow-up observation such as radiograph. Our findings suggest that the novel DM shows high accuracy and reliability for scoliosis screening.
format Online
Article
Text
id pubmed-7306634
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-73066342020-06-23 Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability Sato, Tatsuya Yonezawa, Ikuho Akimoto, Toshinari Nobuyuki, Terada Shimamura, Yukitoshi Muto, Osamu Suzuki, Teppei Momomura, Rei Uno, Koki Yamazaki, Ken Fujiwara, Kenta Misawa, Akiko Kaneko, Kazuo Cureus Orthopedics Background Adolescent idiopathic scoliosis (AIS) is a potentially progressive deformity, and early detection is crucial for timely intervention. However, the methods and criteria justifying screening for pediatric scoliosis remain controversial. We have, therefore, independently developed a Digital Moiré (DM) as a tool for scoliosis screening. The purpose of this study was to assess the usefulness of DM for scoliosis screening. Methods From March 2016 to March 2017, 126 patients (18 boys, 108 girls, mean age: 13.2 ± 2.2 years) with AIS underwent radiographic imaging of their whole spine. We tested the accuracy and reliability of DM by categorizing the examination results as Class 0 (no abnormality), Class 1 (return visit in one year), and Class 2 (further examination needed) and determined the distribution of the population by Cobb angle. The intra/inter-rater reliability and receiver operating characteristic (ROC) analyses were used to categorize the patients with positive findings into Class 1 or 2. Results Regarding the population distribution per Cobb angle in each of the distributions, 11 patients (8.7%) were Class 0, of which nine and two patients had Cobb angle ≤ 10 ° and > 10 °, respectively. There were 20 (15.9% ) Class 1 cases, of which 17 and three had Cobb angle ≤ 10 ° and > 10 °, respectively. Of the 95 (75.4%) Class 2 cases, five and 90 had a Cobb angle of ≤ 10 ° and > 10 °, respectively. The receiver operating characteristic (ROC) analysis of patients with positive findings showed that the area under the curve (AUC), sensitivity, specificity, and false-positive rate were 0.76, 0.98, 0.53, and 0.47, respectively, when predicting Cobb angle > 10°. Intra-rater and inter-rater reliability were 0.73 and 0.70, respectively. Conclusions This study demonstrated the usefulness of DM for determining whether a child with AIS requires a follow-up observation such as radiograph. Our findings suggest that the novel DM shows high accuracy and reliability for scoliosis screening. Cureus 2020-05-21 /pmc/articles/PMC7306634/ /pubmed/32582490 http://dx.doi.org/10.7759/cureus.8229 Text en Copyright © 2020, Sato et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Sato, Tatsuya
Yonezawa, Ikuho
Akimoto, Toshinari
Nobuyuki, Terada
Shimamura, Yukitoshi
Muto, Osamu
Suzuki, Teppei
Momomura, Rei
Uno, Koki
Yamazaki, Ken
Fujiwara, Kenta
Misawa, Akiko
Kaneko, Kazuo
Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability
title Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability
title_full Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability
title_fullStr Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability
title_full_unstemmed Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability
title_short Novel Hump Measurement System With a 3D Camera for Early Diagnosis of Patients With Adolescent Idiopathic Scoliosis: A Study of Accuracy and Reliability
title_sort novel hump measurement system with a 3d camera for early diagnosis of patients with adolescent idiopathic scoliosis: a study of accuracy and reliability
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7306634/
https://www.ncbi.nlm.nih.gov/pubmed/32582490
http://dx.doi.org/10.7759/cureus.8229
work_keys_str_mv AT satotatsuya novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT yonezawaikuho novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT akimototoshinari novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT nobuyukiterada novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT shimamurayukitoshi novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT mutoosamu novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT suzukiteppei novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT momomurarei novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT unokoki novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT yamazakiken novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT fujiwarakenta novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT misawaakiko novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability
AT kanekokazuo novelhumpmeasurementsystemwitha3dcameraforearlydiagnosisofpatientswithadolescentidiopathicscoliosisastudyofaccuracyandreliability