Cargando…
A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments
Thermal infrared cameras provide unique information on surface temperature that can benefit a range of environmental, industrial and agricultural applications. However, the use of uncooled thermal cameras for field and unmanned aerial vehicle (UAV) based data collection is often hampered by vignette...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7308974/ https://www.ncbi.nlm.nih.gov/pubmed/32532127 http://dx.doi.org/10.3390/s20113316 |
_version_ | 1783549116262907904 |
---|---|
author | Aragon, Bruno Johansen, Kasper Parkes, Stephen Malbeteau, Yoann Al-Mashharawi, Samir Al-Amoudi, Talal Andrade, Cristhian F. Turner, Darren Lucieer, Arko McCabe, Matthew F. |
author_facet | Aragon, Bruno Johansen, Kasper Parkes, Stephen Malbeteau, Yoann Al-Mashharawi, Samir Al-Amoudi, Talal Andrade, Cristhian F. Turner, Darren Lucieer, Arko McCabe, Matthew F. |
author_sort | Aragon, Bruno |
collection | PubMed |
description | Thermal infrared cameras provide unique information on surface temperature that can benefit a range of environmental, industrial and agricultural applications. However, the use of uncooled thermal cameras for field and unmanned aerial vehicle (UAV) based data collection is often hampered by vignette effects, sensor drift, ambient temperature influences and measurement bias. Here, we develop and apply an ambient temperature-dependent radiometric calibration function that is evaluated against three thermal infrared sensors (Apogee SI-11(Apogee Electronics, Santa Monica, CA, USA), FLIR A655sc (FLIR Systems, Wilsonville, OR, USA), TeAx 640 (TeAx Technology, Wilnsdorf, Germany)). Upon calibration, all systems demonstrated significant improvement in measured surface temperatures when compared against a temperature modulated black body target. The laboratory calibration process used a series of calibrated resistance temperature detectors to measure the temperature of a black body at different ambient temperatures to derive calibration equations for the thermal data acquired by the three sensors. As a point-collecting device, the Apogee sensor was corrected for sensor bias and ambient temperature influences. For the 2D thermal cameras, each pixel was calibrated independently, with results showing that measurement bias and vignette effects were greatly reduced for the FLIR A655sc (from a root mean squared error (RMSE) of 6.219 to 0.815 degrees Celsius (℃)) and TeAx 640 (from an RMSE of 3.438 to 1.013 ℃) cameras. This relatively straightforward approach for the radiometric calibration of infrared thermal sensors can enable more accurate surface temperature retrievals to support field and UAV-based data collection efforts. |
format | Online Article Text |
id | pubmed-7308974 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73089742020-06-25 A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments Aragon, Bruno Johansen, Kasper Parkes, Stephen Malbeteau, Yoann Al-Mashharawi, Samir Al-Amoudi, Talal Andrade, Cristhian F. Turner, Darren Lucieer, Arko McCabe, Matthew F. Sensors (Basel) Article Thermal infrared cameras provide unique information on surface temperature that can benefit a range of environmental, industrial and agricultural applications. However, the use of uncooled thermal cameras for field and unmanned aerial vehicle (UAV) based data collection is often hampered by vignette effects, sensor drift, ambient temperature influences and measurement bias. Here, we develop and apply an ambient temperature-dependent radiometric calibration function that is evaluated against three thermal infrared sensors (Apogee SI-11(Apogee Electronics, Santa Monica, CA, USA), FLIR A655sc (FLIR Systems, Wilsonville, OR, USA), TeAx 640 (TeAx Technology, Wilnsdorf, Germany)). Upon calibration, all systems demonstrated significant improvement in measured surface temperatures when compared against a temperature modulated black body target. The laboratory calibration process used a series of calibrated resistance temperature detectors to measure the temperature of a black body at different ambient temperatures to derive calibration equations for the thermal data acquired by the three sensors. As a point-collecting device, the Apogee sensor was corrected for sensor bias and ambient temperature influences. For the 2D thermal cameras, each pixel was calibrated independently, with results showing that measurement bias and vignette effects were greatly reduced for the FLIR A655sc (from a root mean squared error (RMSE) of 6.219 to 0.815 degrees Celsius (℃)) and TeAx 640 (from an RMSE of 3.438 to 1.013 ℃) cameras. This relatively straightforward approach for the radiometric calibration of infrared thermal sensors can enable more accurate surface temperature retrievals to support field and UAV-based data collection efforts. MDPI 2020-06-10 /pmc/articles/PMC7308974/ /pubmed/32532127 http://dx.doi.org/10.3390/s20113316 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Aragon, Bruno Johansen, Kasper Parkes, Stephen Malbeteau, Yoann Al-Mashharawi, Samir Al-Amoudi, Talal Andrade, Cristhian F. Turner, Darren Lucieer, Arko McCabe, Matthew F. A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments |
title | A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments |
title_full | A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments |
title_fullStr | A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments |
title_full_unstemmed | A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments |
title_short | A Calibration Procedure for Field and UAV-Based Uncooled Thermal Infrared Instruments |
title_sort | calibration procedure for field and uav-based uncooled thermal infrared instruments |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7308974/ https://www.ncbi.nlm.nih.gov/pubmed/32532127 http://dx.doi.org/10.3390/s20113316 |
work_keys_str_mv | AT aragonbruno acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT johansenkasper acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT parkesstephen acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT malbeteauyoann acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT almashharawisamir acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT alamouditalal acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT andradecristhianf acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT turnerdarren acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT lucieerarko acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT mccabematthewf acalibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT aragonbruno calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT johansenkasper calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT parkesstephen calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT malbeteauyoann calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT almashharawisamir calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT alamouditalal calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT andradecristhianf calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT turnerdarren calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT lucieerarko calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments AT mccabematthewf calibrationprocedureforfieldanduavbaseduncooledthermalinfraredinstruments |