Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning

Oscillatory phenomena abound in many types of signals. Identifying the individual oscillatory components that constitute an observed biological signal leads to profound understanding about the biological system. The instantaneous frequency (IF), the amplitude modulation (AM), and their temporal vari...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Hau-Tieng, Hseu, Shu-Shua, Bien, Mauo-Ying, Kou, Yu Ru, Daubechies, Ingrid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7309332/
https://www.ncbi.nlm.nih.gov/pubmed/24235294
http://dx.doi.org/10.1109/TBME.2013.2288497
_version_ 1783549185577975808
author Wu, Hau-Tieng
Hseu, Shu-Shua
Bien, Mauo-Ying
Kou, Yu Ru
Daubechies, Ingrid
author_facet Wu, Hau-Tieng
Hseu, Shu-Shua
Bien, Mauo-Ying
Kou, Yu Ru
Daubechies, Ingrid
author_sort Wu, Hau-Tieng
collection PubMed
description Oscillatory phenomena abound in many types of signals. Identifying the individual oscillatory components that constitute an observed biological signal leads to profound understanding about the biological system. The instantaneous frequency (IF), the amplitude modulation (AM), and their temporal variability are widely used to describe these oscillatory phenomena. In addition, the shape of the oscillatory pattern, repeated in time for an oscillatory component, is also an important characteristic that can be parametrized appropriately. These parameters can be viewed as phenomenological surrogates for the hidden dynamics of the biological system. To estimate jointly the IF, AM, and shape, this paper applies a novel and robust time-frequency analysis tool, referred to as the synchrosqueezing transform (SST). The usefulness of the model and SST are shown directly in predicting the clinical outcome of ventilator weaning. Compared with traditional respiration parameters, the breath-to-breath variability has been reported to be a better predictor of the outcome of the weaning procedure. So far, however, all these indices normally require at least [Formula: see text] min of data acquisition to ensure predictive power. Moreover, the robustness of these indices to the inevitable noise is rarely discussed. We find that based on the proposed model, SST and only [Formula: see text] min of respiration data, the ROC area under curve of the prediction accuracy is [Formula: see text]. The high predictive power that is achieved in the weaning problem, despite a shorter evaluation period, and the stability to noise suggest that other similar kinds of signal may likewise benefit from the proposed model and SST.
format Online
Article
Text
id pubmed-7309332
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-73093322020-06-25 Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning Wu, Hau-Tieng Hseu, Shu-Shua Bien, Mauo-Ying Kou, Yu Ru Daubechies, Ingrid IEEE Trans Biomed Eng Article Oscillatory phenomena abound in many types of signals. Identifying the individual oscillatory components that constitute an observed biological signal leads to profound understanding about the biological system. The instantaneous frequency (IF), the amplitude modulation (AM), and their temporal variability are widely used to describe these oscillatory phenomena. In addition, the shape of the oscillatory pattern, repeated in time for an oscillatory component, is also an important characteristic that can be parametrized appropriately. These parameters can be viewed as phenomenological surrogates for the hidden dynamics of the biological system. To estimate jointly the IF, AM, and shape, this paper applies a novel and robust time-frequency analysis tool, referred to as the synchrosqueezing transform (SST). The usefulness of the model and SST are shown directly in predicting the clinical outcome of ventilator weaning. Compared with traditional respiration parameters, the breath-to-breath variability has been reported to be a better predictor of the outcome of the weaning procedure. So far, however, all these indices normally require at least [Formula: see text] min of data acquisition to ensure predictive power. Moreover, the robustness of these indices to the inevitable noise is rarely discussed. We find that based on the proposed model, SST and only [Formula: see text] min of respiration data, the ROC area under curve of the prediction accuracy is [Formula: see text]. The high predictive power that is achieved in the weaning problem, despite a shorter evaluation period, and the stability to noise suggest that other similar kinds of signal may likewise benefit from the proposed model and SST. IEEE 2013-11-04 /pmc/articles/PMC7309332/ /pubmed/24235294 http://dx.doi.org/10.1109/TBME.2013.2288497 Text en https://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Wu, Hau-Tieng
Hseu, Shu-Shua
Bien, Mauo-Ying
Kou, Yu Ru
Daubechies, Ingrid
Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning
title Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning
title_full Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning
title_fullStr Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning
title_full_unstemmed Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning
title_short Evaluating Physiological Dynamics via Synchrosqueezing: Prediction of Ventilator Weaning
title_sort evaluating physiological dynamics via synchrosqueezing: prediction of ventilator weaning
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7309332/
https://www.ncbi.nlm.nih.gov/pubmed/24235294
http://dx.doi.org/10.1109/TBME.2013.2288497
work_keys_str_mv AT wuhautieng evaluatingphysiologicaldynamicsviasynchrosqueezingpredictionofventilatorweaning
AT hseushushua evaluatingphysiologicaldynamicsviasynchrosqueezingpredictionofventilatorweaning
AT bienmauoying evaluatingphysiologicaldynamicsviasynchrosqueezingpredictionofventilatorweaning
AT kouyuru evaluatingphysiologicaldynamicsviasynchrosqueezingpredictionofventilatorweaning
AT daubechiesingrid evaluatingphysiologicaldynamicsviasynchrosqueezingpredictionofventilatorweaning