Cargando…

High frequency jet ventilation at the distal end of tracheostenosis during flexible bronchoscopic resection of large intratracheal tumor: Case series

INTRODUCTION: Resection of a large intratracheal tumor with severe obstruction via flexible bronchoscope remains a formidable challenge to anesthesiologists. Many artificial airways positioned proximal to tracheal obstruction can not ensure adequate oxygen supply. How to ensure effective gas exchang...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Guang-Qiu, Wu, Xiao-Mai, Cao, Dong-Hang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7310889/
https://www.ncbi.nlm.nih.gov/pubmed/32569155
http://dx.doi.org/10.1097/MD.0000000000019929
Descripción
Sumario:INTRODUCTION: Resection of a large intratracheal tumor with severe obstruction via flexible bronchoscope remains a formidable challenge to anesthesiologists. Many artificial airways positioned proximal to tracheal obstruction can not ensure adequate oxygen supply. How to ensure effective gas exchange is crucial to the anesthetic management. PATIENT CONCERNS: Five patients of intratracheal tumor occupying 70% to 85% of the tracheal lumen were scheduled for tumor resection via flexible bronchoscope. DIAGNOSIS: The patients were diagnosed with intratracheal tumor based on their symptoms, radiographic findings and tracheoscopy. INTERVENTIONS: We describe a technique of high frequency jet ventilation (HFJV) using an endobronchial suction catheter distal to tracheostenosis during the surgery, which ensured the good supply of oxygen. We applied general anesthesia with preserved spontaneous breathing. A comprehensive anesthesia protocol that emphasizes bilateral superior laryngeal nerve (SLN) block and sufficient topical anesthesia. An endobronchial suction catheter was introduced transnasally into the trachea and then advanced through the tracheostenosis with the tip proximal to the carina under direct vision with the aid of fiber bronchoscope. HFJV was then performed through the suction catheter. OUTCOMES: The S(P)O(2) maintained above 97% during the surgery. Carbon dioxide retention was alleviated obviously when adequate patency of the trachea lumen achieved about 30 min after the beginning of surgery. HFJV was ceased and all patients had satisfactory spontaneous breathing at the end of the procedure. CONCLUSION: HFJV at the distal end of tracheostenosis is a suitable ventilation strategy during flexible bronchoscopic resection of a large intratracheal tumor.