Electromembrane Extraction Using Sacrificial Electrodes

[Image: see text] In this paper, we report the first example of employing a sacrificial electrode in the acceptor solution during electromembrane extraction (EME). The electrode was based on a silver wire with a layer of silver chloride electroplated onto the surface. During EME, the electrode effec...

Descripción completa

Detalles Bibliográficos
Autores principales: Hansen, Frederik A., Jensen, Henrik, Pedersen-Bjergaard, Stig
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7310954/
https://www.ncbi.nlm.nih.gov/pubmed/32202410
http://dx.doi.org/10.1021/acs.analchem.0c00626
_version_ 1783549464929107968
author Hansen, Frederik A.
Jensen, Henrik
Pedersen-Bjergaard, Stig
author_facet Hansen, Frederik A.
Jensen, Henrik
Pedersen-Bjergaard, Stig
author_sort Hansen, Frederik A.
collection PubMed
description [Image: see text] In this paper, we report the first example of employing a sacrificial electrode in the acceptor solution during electromembrane extraction (EME). The electrode was based on a silver wire with a layer of silver chloride electroplated onto the surface. During EME, the electrode effectively inhibited electrolysis of water in the acceptor compartment, by accepting the charge transfer across the SLM, which enabled the application of 500 μA current without suffering gas formation or pH changes from electrolysis of water. The electroplating strategy was optimized with a design-of-experiments (DOE) methodology that provided optimal conditions of electroplating. With an optimized electrode, 1 cm of the electrode in contact with the acceptor solution inhibited electrolysis of water for approximately 30 min at 500 μA current (redox capacity). Further, the redox capacity of the electrode was found to increase through multiple uses. The advantage of the electrode was demonstrated by extracting polar analytes at high-current conditions in a standard EME system comprising 2-nitrophenyl octyl ether (NPOE) as SLM and 10 mM HCl as sample/acceptor solutions. Application of high current enabled significantly higher recoveries than could otherwise be obtained at 100 μA. Sacrificial electrodes were also tested in μ-EME and were found beneficial by eliminating detrimental bubble formation. Thus, the sacrificial electrodes improved the stability of μ-EME systems. The findings of this paper are important for development of stable and robust systems for EME operated at high voltage/current and for EME performed in narrow channels/tubing where bubble formation is critical.
format Online
Article
Text
id pubmed-7310954
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-73109542020-06-24 Electromembrane Extraction Using Sacrificial Electrodes Hansen, Frederik A. Jensen, Henrik Pedersen-Bjergaard, Stig Anal Chem [Image: see text] In this paper, we report the first example of employing a sacrificial electrode in the acceptor solution during electromembrane extraction (EME). The electrode was based on a silver wire with a layer of silver chloride electroplated onto the surface. During EME, the electrode effectively inhibited electrolysis of water in the acceptor compartment, by accepting the charge transfer across the SLM, which enabled the application of 500 μA current without suffering gas formation or pH changes from electrolysis of water. The electroplating strategy was optimized with a design-of-experiments (DOE) methodology that provided optimal conditions of electroplating. With an optimized electrode, 1 cm of the electrode in contact with the acceptor solution inhibited electrolysis of water for approximately 30 min at 500 μA current (redox capacity). Further, the redox capacity of the electrode was found to increase through multiple uses. The advantage of the electrode was demonstrated by extracting polar analytes at high-current conditions in a standard EME system comprising 2-nitrophenyl octyl ether (NPOE) as SLM and 10 mM HCl as sample/acceptor solutions. Application of high current enabled significantly higher recoveries than could otherwise be obtained at 100 μA. Sacrificial electrodes were also tested in μ-EME and were found beneficial by eliminating detrimental bubble formation. Thus, the sacrificial electrodes improved the stability of μ-EME systems. The findings of this paper are important for development of stable and robust systems for EME operated at high voltage/current and for EME performed in narrow channels/tubing where bubble formation is critical. American Chemical Society 2020-03-23 2020-04-07 /pmc/articles/PMC7310954/ /pubmed/32202410 http://dx.doi.org/10.1021/acs.analchem.0c00626 Text en Copyright © 2020 American Chemical Society This is an open access article published under a Creative Commons Attribution (CC-BY) License (http://pubs.acs.org/page/policy/authorchoice_ccby_termsofuse.html) , which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited.
spellingShingle Hansen, Frederik A.
Jensen, Henrik
Pedersen-Bjergaard, Stig
Electromembrane Extraction Using Sacrificial Electrodes
title Electromembrane Extraction Using Sacrificial Electrodes
title_full Electromembrane Extraction Using Sacrificial Electrodes
title_fullStr Electromembrane Extraction Using Sacrificial Electrodes
title_full_unstemmed Electromembrane Extraction Using Sacrificial Electrodes
title_short Electromembrane Extraction Using Sacrificial Electrodes
title_sort electromembrane extraction using sacrificial electrodes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7310954/
https://www.ncbi.nlm.nih.gov/pubmed/32202410
http://dx.doi.org/10.1021/acs.analchem.0c00626
work_keys_str_mv AT hansenfrederika electromembraneextractionusingsacrificialelectrodes
AT jensenhenrik electromembraneextractionusingsacrificialelectrodes
AT pedersenbjergaardstig electromembraneextractionusingsacrificialelectrodes