Cargando…

Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis

Isoprostanes are physiopathologic mediators of oxidative stress, resulting in lipid peroxidation. 8-isoprostane seems particularly useful for measuring oxidative stress damage. However, no reference range values are available for 8-isoprosante in exhaled breath condensate (EBC) of healthy adults, en...

Descripción completa

Detalles Bibliográficos
Autores principales: Shoman, Yara, Wild, Pascal, Hemmendinger, Maud, Graille, Melanie, Sauvain, Jean-Jacques, B. Hopf, Nancy, Guseva Canu, Irina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7311981/
https://www.ncbi.nlm.nih.gov/pubmed/32481492
http://dx.doi.org/10.3390/ijms21113822
_version_ 1783549628690464768
author Shoman, Yara
Wild, Pascal
Hemmendinger, Maud
Graille, Melanie
Sauvain, Jean-Jacques
B. Hopf, Nancy
Guseva Canu, Irina
author_facet Shoman, Yara
Wild, Pascal
Hemmendinger, Maud
Graille, Melanie
Sauvain, Jean-Jacques
B. Hopf, Nancy
Guseva Canu, Irina
author_sort Shoman, Yara
collection PubMed
description Isoprostanes are physiopathologic mediators of oxidative stress, resulting in lipid peroxidation. 8-isoprostane seems particularly useful for measuring oxidative stress damage. However, no reference range values are available for 8-isoprosante in exhaled breath condensate (EBC) of healthy adults, enabling its meaningful interpretation as a biomarker. We conducted this systematic review and meta-analysis according to the protocol following PROSPERO (CRD42020146623). After searching and analyzing the literature, we included 86 studies. After their qualitative synthesis and risk of bias assessment, 52 studies were included in meta-analysis. The latter focused on studies using immunological analytical methods and investigated how the concentrations of 8-isoprostane differ based on gender. We found that gender had no significant effect in 8-isoprostane concentration. Among other studied factors, such as individual characteristics and factors related to EBC collection, only the device used for EBC collection significantly affected measured 8-isoprostane concentrations. However, adjustment for the factors related to EBC collection, yielded uncertainty whether this effect is due to the device itself or to the other factors. Given this uncertainty, we estimated the reference range values of 8-isoprostane stratified by gender and EBC collection device. A better standardization of EBC collection seems necessary; as well more studies using chemical analytical methods to extend this investigation.
format Online
Article
Text
id pubmed-7311981
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73119812020-06-25 Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis Shoman, Yara Wild, Pascal Hemmendinger, Maud Graille, Melanie Sauvain, Jean-Jacques B. Hopf, Nancy Guseva Canu, Irina Int J Mol Sci Review Isoprostanes are physiopathologic mediators of oxidative stress, resulting in lipid peroxidation. 8-isoprostane seems particularly useful for measuring oxidative stress damage. However, no reference range values are available for 8-isoprosante in exhaled breath condensate (EBC) of healthy adults, enabling its meaningful interpretation as a biomarker. We conducted this systematic review and meta-analysis according to the protocol following PROSPERO (CRD42020146623). After searching and analyzing the literature, we included 86 studies. After their qualitative synthesis and risk of bias assessment, 52 studies were included in meta-analysis. The latter focused on studies using immunological analytical methods and investigated how the concentrations of 8-isoprostane differ based on gender. We found that gender had no significant effect in 8-isoprostane concentration. Among other studied factors, such as individual characteristics and factors related to EBC collection, only the device used for EBC collection significantly affected measured 8-isoprostane concentrations. However, adjustment for the factors related to EBC collection, yielded uncertainty whether this effect is due to the device itself or to the other factors. Given this uncertainty, we estimated the reference range values of 8-isoprostane stratified by gender and EBC collection device. A better standardization of EBC collection seems necessary; as well more studies using chemical analytical methods to extend this investigation. MDPI 2020-05-28 /pmc/articles/PMC7311981/ /pubmed/32481492 http://dx.doi.org/10.3390/ijms21113822 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Shoman, Yara
Wild, Pascal
Hemmendinger, Maud
Graille, Melanie
Sauvain, Jean-Jacques
B. Hopf, Nancy
Guseva Canu, Irina
Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis
title Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis
title_full Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis
title_fullStr Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis
title_full_unstemmed Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis
title_short Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis
title_sort reference ranges of 8-isoprostane concentrations in exhaled breath condensate (ebc): a systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7311981/
https://www.ncbi.nlm.nih.gov/pubmed/32481492
http://dx.doi.org/10.3390/ijms21113822
work_keys_str_mv AT shomanyara referencerangesof8isoprostaneconcentrationsinexhaledbreathcondensateebcasystematicreviewandmetaanalysis
AT wildpascal referencerangesof8isoprostaneconcentrationsinexhaledbreathcondensateebcasystematicreviewandmetaanalysis
AT hemmendingermaud referencerangesof8isoprostaneconcentrationsinexhaledbreathcondensateebcasystematicreviewandmetaanalysis
AT graillemelanie referencerangesof8isoprostaneconcentrationsinexhaledbreathcondensateebcasystematicreviewandmetaanalysis
AT sauvainjeanjacques referencerangesof8isoprostaneconcentrationsinexhaledbreathcondensateebcasystematicreviewandmetaanalysis
AT bhopfnancy referencerangesof8isoprostaneconcentrationsinexhaledbreathcondensateebcasystematicreviewandmetaanalysis
AT gusevacanuirina referencerangesof8isoprostaneconcentrationsinexhaledbreathcondensateebcasystematicreviewandmetaanalysis