Cargando…
A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide
Objective: The development of digital dentistry has contributed to the astonishing advancement of implant dentistry. Furthermore, digital technology is expected to be applied extensively to sinus augmentation, which is an advanced technique for implant surgery. This study introduces a simple method...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7313061/ https://www.ncbi.nlm.nih.gov/pubmed/32471026 http://dx.doi.org/10.3390/ijerph17113785 |
_version_ | 1783549872214900736 |
---|---|
author | Cho, Seoung-Won Yang, Byoung-Eun Cheon, Kyeong-Jun Jang, Won-Seok Kim, Ju-Won Byun, Soo-Hwan |
author_facet | Cho, Seoung-Won Yang, Byoung-Eun Cheon, Kyeong-Jun Jang, Won-Seok Kim, Ju-Won Byun, Soo-Hwan |
author_sort | Cho, Seoung-Won |
collection | PubMed |
description | Objective: The development of digital dentistry has contributed to the astonishing advancement of implant dentistry. Furthermore, digital technology is expected to be applied extensively to sinus augmentation, which is an advanced technique for implant surgery. This study introduces a simple method for a safer and more precise lateral window opening for sinus augmentation using a navigation program. Methods: Five eligible patients with residual alveolar bone of 4 mm or less are presented, requiring lateral approach for sinus augmentation. Navigation system was opted for the sinus lift with simultaneous implant placement. Virtual planning started with establishing the adequate position of the lateral window based on the radiographic images and the scanned file of the dentition. The position of the window was indicated on the guide within the program. Afterwards, the virtually designed surgical guide was fabricated either with 3D printer or milling machine for the actual surgery. Results: All the patients who underwent surgery with the surgical guide showed no sign of clinical complications including pain, swelling, nausea, epistaxis, or early loss of the implants. Results of radiographic evaluation also showed adequate placement of the implants in a pre-planned position, and the sinus window was also formed in the desired location. Conclusion: Lateral window opening combined with digital navigation system is believed to be a promising technique for a more precise as well as safer sinus augmentation. |
format | Online Article Text |
id | pubmed-7313061 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73130612020-06-29 A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide Cho, Seoung-Won Yang, Byoung-Eun Cheon, Kyeong-Jun Jang, Won-Seok Kim, Ju-Won Byun, Soo-Hwan Int J Environ Res Public Health Article Objective: The development of digital dentistry has contributed to the astonishing advancement of implant dentistry. Furthermore, digital technology is expected to be applied extensively to sinus augmentation, which is an advanced technique for implant surgery. This study introduces a simple method for a safer and more precise lateral window opening for sinus augmentation using a navigation program. Methods: Five eligible patients with residual alveolar bone of 4 mm or less are presented, requiring lateral approach for sinus augmentation. Navigation system was opted for the sinus lift with simultaneous implant placement. Virtual planning started with establishing the adequate position of the lateral window based on the radiographic images and the scanned file of the dentition. The position of the window was indicated on the guide within the program. Afterwards, the virtually designed surgical guide was fabricated either with 3D printer or milling machine for the actual surgery. Results: All the patients who underwent surgery with the surgical guide showed no sign of clinical complications including pain, swelling, nausea, epistaxis, or early loss of the implants. Results of radiographic evaluation also showed adequate placement of the implants in a pre-planned position, and the sinus window was also formed in the desired location. Conclusion: Lateral window opening combined with digital navigation system is believed to be a promising technique for a more precise as well as safer sinus augmentation. MDPI 2020-05-27 2020-06 /pmc/articles/PMC7313061/ /pubmed/32471026 http://dx.doi.org/10.3390/ijerph17113785 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Cho, Seoung-Won Yang, Byoung-Eun Cheon, Kyeong-Jun Jang, Won-Seok Kim, Ju-Won Byun, Soo-Hwan A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide |
title | A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide |
title_full | A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide |
title_fullStr | A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide |
title_full_unstemmed | A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide |
title_short | A Simple and Safe Approach for Maxillary Sinus Augmentation with the Advanced Surgical Guide |
title_sort | simple and safe approach for maxillary sinus augmentation with the advanced surgical guide |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7313061/ https://www.ncbi.nlm.nih.gov/pubmed/32471026 http://dx.doi.org/10.3390/ijerph17113785 |
work_keys_str_mv | AT choseoungwon asimpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT yangbyoungeun asimpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT cheonkyeongjun asimpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT jangwonseok asimpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT kimjuwon asimpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT byunsoohwan asimpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT choseoungwon simpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT yangbyoungeun simpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT cheonkyeongjun simpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT jangwonseok simpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT kimjuwon simpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide AT byunsoohwan simpleandsafeapproachformaxillarysinusaugmentationwiththeadvancedsurgicalguide |