Cargando…
Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective
The feasibility and safety of same-day discharge after transvenous implantable cardioverter-defibrillator implantation is well-established. However, subcutaneous ICDs (S-ICDs) are now increasingly being implanted, and the feasibility, safety, and potential cost savings associated with same-day disch...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MediaSphere Medical
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7313622/ https://www.ncbi.nlm.nih.gov/pubmed/32596027 http://dx.doi.org/10.19102/icrm.2020.110602 |
_version_ | 1783549978036142080 |
---|---|
author | Swinning, Jill Fox, Kelli Billakanty, Sreedhar Brown, Shannon Chopra, Nagesh Fu, Eugene James, Jennifer Kidwell, Gregory Kleman, James Murnane, Victoria Nelson, Steven Nichols, Allan Nichols, S. Kay Robinson, Andrea Amin, Anish |
author_facet | Swinning, Jill Fox, Kelli Billakanty, Sreedhar Brown, Shannon Chopra, Nagesh Fu, Eugene James, Jennifer Kidwell, Gregory Kleman, James Murnane, Victoria Nelson, Steven Nichols, Allan Nichols, S. Kay Robinson, Andrea Amin, Anish |
author_sort | Swinning, Jill |
collection | PubMed |
description | The feasibility and safety of same-day discharge after transvenous implantable cardioverter-defibrillator implantation is well-established. However, subcutaneous ICDs (S-ICDs) are now increasingly being implanted, and the feasibility, safety, and potential cost savings associated with same-day discharge after S-ICD placement has not been widely investigated. In a small cohort of patients (n = 24) who underwent S-ICD implantation at our institution, 54% were successfully discharged on the same day as their implant procedure. Procedure-related complications were not apparent in this sampling and the reduction in health care costs was high, suggesting this protocol has immense benefit in today’s health care environment. As such, same-day discharge of S-ICD patients is appropriate to consider and should receive further attention. |
format | Online Article Text |
id | pubmed-7313622 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MediaSphere Medical |
record_format | MEDLINE/PubMed |
spelling | pubmed-73136222020-06-25 Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective Swinning, Jill Fox, Kelli Billakanty, Sreedhar Brown, Shannon Chopra, Nagesh Fu, Eugene James, Jennifer Kidwell, Gregory Kleman, James Murnane, Victoria Nelson, Steven Nichols, Allan Nichols, S. Kay Robinson, Andrea Amin, Anish J Innov Card Rhythm Manag Original Research The feasibility and safety of same-day discharge after transvenous implantable cardioverter-defibrillator implantation is well-established. However, subcutaneous ICDs (S-ICDs) are now increasingly being implanted, and the feasibility, safety, and potential cost savings associated with same-day discharge after S-ICD placement has not been widely investigated. In a small cohort of patients (n = 24) who underwent S-ICD implantation at our institution, 54% were successfully discharged on the same day as their implant procedure. Procedure-related complications were not apparent in this sampling and the reduction in health care costs was high, suggesting this protocol has immense benefit in today’s health care environment. As such, same-day discharge of S-ICD patients is appropriate to consider and should receive further attention. MediaSphere Medical 2020-06-15 /pmc/articles/PMC7313622/ /pubmed/32596027 http://dx.doi.org/10.19102/icrm.2020.110602 Text en Copyright: © 2020 Innovations in Cardiac Rhythm Management http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Swinning, Jill Fox, Kelli Billakanty, Sreedhar Brown, Shannon Chopra, Nagesh Fu, Eugene James, Jennifer Kidwell, Gregory Kleman, James Murnane, Victoria Nelson, Steven Nichols, Allan Nichols, S. Kay Robinson, Andrea Amin, Anish Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective |
title | Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective |
title_full | Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective |
title_fullStr | Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective |
title_full_unstemmed | Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective |
title_short | Same-day Discharge after Subcutaneous Implantable Cardioverter-defibrillator Implantation is Safe and Cost-effective |
title_sort | same-day discharge after subcutaneous implantable cardioverter-defibrillator implantation is safe and cost-effective |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7313622/ https://www.ncbi.nlm.nih.gov/pubmed/32596027 http://dx.doi.org/10.19102/icrm.2020.110602 |
work_keys_str_mv | AT swinningjill samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT foxkelli samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT billakantysreedhar samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT brownshannon samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT chopranagesh samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT fueugene samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT jamesjennifer samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT kidwellgregory samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT klemanjames samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT murnanevictoria samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT nelsonsteven samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT nicholsallan samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT nicholsskay samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT robinsonandrea samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective AT aminanish samedaydischargeaftersubcutaneousimplantablecardioverterdefibrillatorimplantationissafeandcosteffective |