Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density
PURPOSE: This study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. MATERIALS AND METHODS: The sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7314611/ https://www.ncbi.nlm.nih.gov/pubmed/32601590 http://dx.doi.org/10.5624/isd.2020.50.2.153 |
_version_ | 1783550096570318848 |
---|---|
author | Gaêta-Araujo, Hugo Nascimento, Eduarda Helena Leandro Brasil, Danieli Moura Madlum, Daniela Verardi Haiter-Neto, Francisco Oliveira-Santos, Christiano |
author_facet | Gaêta-Araujo, Hugo Nascimento, Eduarda Helena Leandro Brasil, Danieli Moura Madlum, Daniela Verardi Haiter-Neto, Francisco Oliveira-Santos, Christiano |
author_sort | Gaêta-Araujo, Hugo |
collection | PubMed |
description | PURPOSE: This study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. MATERIALS AND METHODS: The sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174 unit (Bruker, Kontich, Belgium). Each acquisition was reconstructed following the manufacturer's recommendations (standard protocol; SP) for the application of artifact correction tools (beam hardening correction [BHC], 45%; smoothing filter, degree 2; and ring artifact correction [RAC], level 5). Additionally, images were reconstructed with 36 protocols combining different settings of artifact correction tools (P0 to P35). BMD analysis was performed for each reconstructed image. The BMD values obtained for each protocol were compared to those obtained using the SP through repeated-measures analysis of variance with the Dunnett post hoc test (α=0.05). RESULTS: The BMD values obtained from all protocols that used a BHC of 45% did not significantly differ from those obtained using the SP (P>0.05). The other protocols all yielded significantly different BMD values from the SP (P<0.05). The smoothing and RAC tools did not affect BMD values. CONCLUSION: BMD values measured on micro-CT images were influenced by the BHC level. Higher levels of BHC induced higher values of BMD. |
format | Online Article Text |
id | pubmed-7314611 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-73146112020-06-28 Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density Gaêta-Araujo, Hugo Nascimento, Eduarda Helena Leandro Brasil, Danieli Moura Madlum, Daniela Verardi Haiter-Neto, Francisco Oliveira-Santos, Christiano Imaging Sci Dent Original Article PURPOSE: This study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. MATERIALS AND METHODS: The sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174 unit (Bruker, Kontich, Belgium). Each acquisition was reconstructed following the manufacturer's recommendations (standard protocol; SP) for the application of artifact correction tools (beam hardening correction [BHC], 45%; smoothing filter, degree 2; and ring artifact correction [RAC], level 5). Additionally, images were reconstructed with 36 protocols combining different settings of artifact correction tools (P0 to P35). BMD analysis was performed for each reconstructed image. The BMD values obtained for each protocol were compared to those obtained using the SP through repeated-measures analysis of variance with the Dunnett post hoc test (α=0.05). RESULTS: The BMD values obtained from all protocols that used a BHC of 45% did not significantly differ from those obtained using the SP (P>0.05). The other protocols all yielded significantly different BMD values from the SP (P<0.05). The smoothing and RAC tools did not affect BMD values. CONCLUSION: BMD values measured on micro-CT images were influenced by the BHC level. Higher levels of BHC induced higher values of BMD. Korean Academy of Oral and Maxillofacial Radiology 2020-06 2020-06-18 /pmc/articles/PMC7314611/ /pubmed/32601590 http://dx.doi.org/10.5624/isd.2020.50.2.153 Text en Copyright © 2020 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Gaêta-Araujo, Hugo Nascimento, Eduarda Helena Leandro Brasil, Danieli Moura Madlum, Daniela Verardi Haiter-Neto, Francisco Oliveira-Santos, Christiano Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density |
title | Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density |
title_full | Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density |
title_fullStr | Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density |
title_full_unstemmed | Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density |
title_short | Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density |
title_sort | influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7314611/ https://www.ncbi.nlm.nih.gov/pubmed/32601590 http://dx.doi.org/10.5624/isd.2020.50.2.153 |
work_keys_str_mv | AT gaetaaraujohugo influenceofreconstructionparametersofmicrocomputedtomographyontheanalysisofbonemineraldensity AT nascimentoeduardahelenaleandro influenceofreconstructionparametersofmicrocomputedtomographyontheanalysisofbonemineraldensity AT brasildanielimoura influenceofreconstructionparametersofmicrocomputedtomographyontheanalysisofbonemineraldensity AT madlumdanielaverardi influenceofreconstructionparametersofmicrocomputedtomographyontheanalysisofbonemineraldensity AT haiternetofrancisco influenceofreconstructionparametersofmicrocomputedtomographyontheanalysisofbonemineraldensity AT oliveirasantoschristiano influenceofreconstructionparametersofmicrocomputedtomographyontheanalysisofbonemineraldensity |