Cargando…

Evaluation of corrosion resistance of Co-Cr alloys fabricated with different metal laser sintering systems

PURPOSE: The aim of this study was to evaluate the corrosion resistance of the specimens produced by five different commercial metal laser sintering (MLS) systems with their recommended Co-Cr alloy powders. MATERIALS AND METHODS: The MLS machines and the alloy powders used were, ProX 100-ST2724G (St...

Descripción completa

Detalles Bibliográficos
Autores principales: Tuna, Süleyman Hakan, Karaca, Erhan, Aslan, İsmail, Pekkan, Gürel, Pekmez, Nuran Özçiçek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7314628/
https://www.ncbi.nlm.nih.gov/pubmed/32601530
http://dx.doi.org/10.4047/jap.2020.12.3.114
Descripción
Sumario:PURPOSE: The aim of this study was to evaluate the corrosion resistance of the specimens produced by five different commercial metal laser sintering (MLS) systems with their recommended Co-Cr alloy powders. MATERIALS AND METHODS: The MLS machines and the alloy powders used were, ProX 100-ST2724G (St-Pro), Mysint 100-EOS SP2 (SP2-Mys), EOSINT 270-EOS SP2 (SP2-EOS), SLM 100-Starbond CoS (SB-SLM), and MLab Cusing-Remanium® Star (RS-MLab), respectively. Eight specimens from each group were prepared. Open circuit potential (E(ocp)) and electrochemical impedance spectroscopy (EIS) measurements of polished surfaces of the specimens were conducted in a three-electrode cell using a potentiostat-galvanostat in Fusayama-Meyer artificial saliva (AS). Specimens from each group were immersed in AS and de-ionized water for seven days. E(ocp), charge transfer resistance (R(ct)) values, and released ions (µg/cm(2) × 7d) in different solutions were determined. The specimen surfaces were observed with SEM/EDS. Results were analyzed statistically. RESULTS: E(ocp) values have shifted to potentials that are more positive over time. Steady-state E(ocp) values were from high to low as follows, SB-SLM, SP2-Mys, SP2-EOS, RS-MLab, and ST-Pro, respectively. After 60 mins, RS-MLab specimens had the highest R(ct) value, followed by SP2-Mys, SB-SLM, SP2-EOS, and ST-Pro. In all groups, ion release was higher in AS than that in de-ionized water. CONCLUSION: There were small differences among the corrosion resistances of the Co-Cr alloy specimens produced with MLS systems; meanwhile, the corrosion resistances were quite high for all specimens.