Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
PURPOSE: This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two techniques. METHODS: This retrospective study included 249 patients who underwent LS measurements usin...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Ultrasound in Medicine
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315295/ https://www.ncbi.nlm.nih.gov/pubmed/32311869 http://dx.doi.org/10.14366/usg.19090 |
_version_ | 1783550227599327232 |
---|---|
author | Lee, Sang Min Kim, Min-Jeong Yoon, Jeong Hee Hong, Wonju Ha, Hong Il Lee, Kwanseop Choe, Ji-Young Lee, Jung Woo Yoon, Sam-Youl Han, Junhee |
author_facet | Lee, Sang Min Kim, Min-Jeong Yoon, Jeong Hee Hong, Wonju Ha, Hong Il Lee, Kwanseop Choe, Ji-Young Lee, Jung Woo Yoon, Sam-Youl Han, Junhee |
author_sort | Lee, Sang Min |
collection | PubMed |
description | PURPOSE: This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two techniques. METHODS: This retrospective study included 249 patients who underwent LS measurements using both ElastPQ and ElastQ Imaging equipped on the same machine. The applicability, repeatability (coefficient of variation [CV]), acquisition time, and LS values were compared using the chi-square or Wilcoxon signed-rank tests. In the development group, the correlation between the LS values obtained by the two techniques was assessed with Spearman correlation coefficients and linear regression analysis. In the validation group, the agreement between the estimated and real LS values was evaluated using a Bland-Altman plot. RESULTS: ElastQ Imaging had higher applicability (94.0% vs. 78.3%, P<0.001) and higher repeatability, with a lower median CV (0.127 vs. 0.164, P<0.001) than did ElastPQ. The median acquisition time of ElastQ Imaging was significantly shorter than that of ElastPQ (45.5 seconds vs. 96.5 seconds, P<0.001). The median LS value obtained using ElastQ Imaging was significantly higher than that obtained using ElastPQ (5.60 kPa vs. 5.23 kPa, P<0.001). The LS values between the two techniques exhibited a strong positive correlation (r=0.851, P<0.001) in the development group. The mean difference and 95% limits of agreement were 0.0 kPa (-3.9 to 3.9 kPa) in the validation group. CONCLUSION: ElastQ Imaging may be more reliable and faster than ElastPQ, with strongly correlated LS measurements. |
format | Online Article Text |
id | pubmed-7315295 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Society of Ultrasound in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-73152952020-07-01 Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis Lee, Sang Min Kim, Min-Jeong Yoon, Jeong Hee Hong, Wonju Ha, Hong Il Lee, Kwanseop Choe, Ji-Young Lee, Jung Woo Yoon, Sam-Youl Han, Junhee Ultrasonography Original Article PURPOSE: This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two techniques. METHODS: This retrospective study included 249 patients who underwent LS measurements using both ElastPQ and ElastQ Imaging equipped on the same machine. The applicability, repeatability (coefficient of variation [CV]), acquisition time, and LS values were compared using the chi-square or Wilcoxon signed-rank tests. In the development group, the correlation between the LS values obtained by the two techniques was assessed with Spearman correlation coefficients and linear regression analysis. In the validation group, the agreement between the estimated and real LS values was evaluated using a Bland-Altman plot. RESULTS: ElastQ Imaging had higher applicability (94.0% vs. 78.3%, P<0.001) and higher repeatability, with a lower median CV (0.127 vs. 0.164, P<0.001) than did ElastPQ. The median acquisition time of ElastQ Imaging was significantly shorter than that of ElastPQ (45.5 seconds vs. 96.5 seconds, P<0.001). The median LS value obtained using ElastQ Imaging was significantly higher than that obtained using ElastPQ (5.60 kPa vs. 5.23 kPa, P<0.001). The LS values between the two techniques exhibited a strong positive correlation (r=0.851, P<0.001) in the development group. The mean difference and 95% limits of agreement were 0.0 kPa (-3.9 to 3.9 kPa) in the validation group. CONCLUSION: ElastQ Imaging may be more reliable and faster than ElastPQ, with strongly correlated LS measurements. Korean Society of Ultrasound in Medicine 2020-07 2020-03-06 /pmc/articles/PMC7315295/ /pubmed/32311869 http://dx.doi.org/10.14366/usg.19090 Text en Copyright © 2020 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Sang Min Kim, Min-Jeong Yoon, Jeong Hee Hong, Wonju Ha, Hong Il Lee, Kwanseop Choe, Ji-Young Lee, Jung Woo Yoon, Sam-Youl Han, Junhee Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis |
title | Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis |
title_full | Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis |
title_fullStr | Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis |
title_full_unstemmed | Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis |
title_short | Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis |
title_sort | comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315295/ https://www.ncbi.nlm.nih.gov/pubmed/32311869 http://dx.doi.org/10.14366/usg.19090 |
work_keys_str_mv | AT leesangmin comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT kimminjeong comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT yoonjeonghee comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT hongwonju comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT hahongil comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT leekwanseop comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT choejiyoung comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT leejungwoo comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT yoonsamyoul comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis AT hanjunhee comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis |