PURPOSE: This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two techniques. METHODS: This retrospective study included 249 patients who underwent LS measurements usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang Min, Kim, Min-Jeong, Yoon, Jeong Hee, Hong, Wonju, Ha, Hong Il, Lee, Kwanseop, Choe, Ji-Young, Lee, Jung Woo, Yoon, Sam-Youl, Han, Junhee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315295/
https://www.ncbi.nlm.nih.gov/pubmed/32311869
http://dx.doi.org/10.14366/usg.19090
_version_ 1783550227599327232
author Lee, Sang Min
Kim, Min-Jeong
Yoon, Jeong Hee
Hong, Wonju
Ha, Hong Il
Lee, Kwanseop
Choe, Ji-Young
Lee, Jung Woo
Yoon, Sam-Youl
Han, Junhee
author_facet Lee, Sang Min
Kim, Min-Jeong
Yoon, Jeong Hee
Hong, Wonju
Ha, Hong Il
Lee, Kwanseop
Choe, Ji-Young
Lee, Jung Woo
Yoon, Sam-Youl
Han, Junhee
author_sort Lee, Sang Min
collection PubMed
description PURPOSE: This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two techniques. METHODS: This retrospective study included 249 patients who underwent LS measurements using both ElastPQ and ElastQ Imaging equipped on the same machine. The applicability, repeatability (coefficient of variation [CV]), acquisition time, and LS values were compared using the chi-square or Wilcoxon signed-rank tests. In the development group, the correlation between the LS values obtained by the two techniques was assessed with Spearman correlation coefficients and linear regression analysis. In the validation group, the agreement between the estimated and real LS values was evaluated using a Bland-Altman plot. RESULTS: ElastQ Imaging had higher applicability (94.0% vs. 78.3%, P<0.001) and higher repeatability, with a lower median CV (0.127 vs. 0.164, P<0.001) than did ElastPQ. The median acquisition time of ElastQ Imaging was significantly shorter than that of ElastPQ (45.5 seconds vs. 96.5 seconds, P<0.001). The median LS value obtained using ElastQ Imaging was significantly higher than that obtained using ElastPQ (5.60 kPa vs. 5.23 kPa, P<0.001). The LS values between the two techniques exhibited a strong positive correlation (r=0.851, P<0.001) in the development group. The mean difference and 95% limits of agreement were 0.0 kPa (-3.9 to 3.9 kPa) in the validation group. CONCLUSION: ElastQ Imaging may be more reliable and faster than ElastPQ, with strongly correlated LS measurements.
format Online
Article
Text
id pubmed-7315295
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-73152952020-07-01 Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis Lee, Sang Min Kim, Min-Jeong Yoon, Jeong Hee Hong, Wonju Ha, Hong Il Lee, Kwanseop Choe, Ji-Young Lee, Jung Woo Yoon, Sam-Youl Han, Junhee Ultrasonography Original Article PURPOSE: This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two techniques. METHODS: This retrospective study included 249 patients who underwent LS measurements using both ElastPQ and ElastQ Imaging equipped on the same machine. The applicability, repeatability (coefficient of variation [CV]), acquisition time, and LS values were compared using the chi-square or Wilcoxon signed-rank tests. In the development group, the correlation between the LS values obtained by the two techniques was assessed with Spearman correlation coefficients and linear regression analysis. In the validation group, the agreement between the estimated and real LS values was evaluated using a Bland-Altman plot. RESULTS: ElastQ Imaging had higher applicability (94.0% vs. 78.3%, P<0.001) and higher repeatability, with a lower median CV (0.127 vs. 0.164, P<0.001) than did ElastPQ. The median acquisition time of ElastQ Imaging was significantly shorter than that of ElastPQ (45.5 seconds vs. 96.5 seconds, P<0.001). The median LS value obtained using ElastQ Imaging was significantly higher than that obtained using ElastPQ (5.60 kPa vs. 5.23 kPa, P<0.001). The LS values between the two techniques exhibited a strong positive correlation (r=0.851, P<0.001) in the development group. The mean difference and 95% limits of agreement were 0.0 kPa (-3.9 to 3.9 kPa) in the validation group. CONCLUSION: ElastQ Imaging may be more reliable and faster than ElastPQ, with strongly correlated LS measurements. Korean Society of Ultrasound in Medicine 2020-07 2020-03-06 /pmc/articles/PMC7315295/ /pubmed/32311869 http://dx.doi.org/10.14366/usg.19090 Text en Copyright © 2020 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Sang Min
Kim, Min-Jeong
Yoon, Jeong Hee
Hong, Wonju
Ha, Hong Il
Lee, Kwanseop
Choe, Ji-Young
Lee, Jung Woo
Yoon, Sam-Youl
Han, Junhee
Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
title Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
title_full Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
title_fullStr Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
title_full_unstemmed Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
title_short Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
title_sort comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315295/
https://www.ncbi.nlm.nih.gov/pubmed/32311869
http://dx.doi.org/10.14366/usg.19090
work_keys_str_mv AT leesangmin comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT kimminjeong comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT yoonjeonghee comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT hongwonju comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT hahongil comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT leekwanseop comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT choejiyoung comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT leejungwoo comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT yoonsamyoul comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis
AT hanjunhee comparisonofpointand2dimensionalshearwaveelastographyfortheevaluationofliverfibrosis