Cargando…

Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?

A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscul...

Descripción completa

Detalles Bibliográficos
Autores principales: Sirico, Giusy, Montisci, Andrea, Secchi, Francesco, Mantica, Massimo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Pacini Editore Srl 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315899/
https://www.ncbi.nlm.nih.gov/pubmed/32607478
http://dx.doi.org/10.36185/2532-1900-006
_version_ 1783550340170252288
author Sirico, Giusy
Montisci, Andrea
Secchi, Francesco
Mantica, Massimo
author_facet Sirico, Giusy
Montisci, Andrea
Secchi, Francesco
Mantica, Massimo
author_sort Sirico, Giusy
collection PubMed
description A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation.
format Online
Article
Text
id pubmed-7315899
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Pacini Editore Srl
record_format MEDLINE/PubMed
spelling pubmed-73158992020-06-29 Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? Sirico, Giusy Montisci, Andrea Secchi, Francesco Mantica, Massimo Acta Myol Case Report A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation. Pacini Editore Srl 2020-03-01 /pmc/articles/PMC7315899/ /pubmed/32607478 http://dx.doi.org/10.36185/2532-1900-006 Text en ©2020 Gaetano Conte Academy - Mediterranean Society of Myology, Naples, Italy https://creativecommons.org/licenses/by-nc-nd/4.0/deed.en This is an open access article distributed in accordance with the CC-BY-NC-ND (Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International) license. The article can be used by giving appropriate credit and mentioning the license, but only for non-commercial purposes and only in the original version. For further information: https://creativecommons.org/licenses/by-nc-nd/4.0/deed.en
spellingShingle Case Report
Sirico, Giusy
Montisci, Andrea
Secchi, Francesco
Mantica, Massimo
Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?
title Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?
title_full Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?
title_fullStr Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?
title_full_unstemmed Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?
title_short Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?
title_sort myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: icd yes or not?
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315899/
https://www.ncbi.nlm.nih.gov/pubmed/32607478
http://dx.doi.org/10.36185/2532-1900-006
work_keys_str_mv AT siricogiusy myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot
AT montisciandrea myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot
AT secchifrancesco myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot
AT manticamassimo myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot