Cargando…
Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?
A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscul...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Pacini Editore Srl
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315899/ https://www.ncbi.nlm.nih.gov/pubmed/32607478 http://dx.doi.org/10.36185/2532-1900-006 |
_version_ | 1783550340170252288 |
---|---|
author | Sirico, Giusy Montisci, Andrea Secchi, Francesco Mantica, Massimo |
author_facet | Sirico, Giusy Montisci, Andrea Secchi, Francesco Mantica, Massimo |
author_sort | Sirico, Giusy |
collection | PubMed |
description | A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation. |
format | Online Article Text |
id | pubmed-7315899 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Pacini Editore Srl |
record_format | MEDLINE/PubMed |
spelling | pubmed-73158992020-06-29 Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? Sirico, Giusy Montisci, Andrea Secchi, Francesco Mantica, Massimo Acta Myol Case Report A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation. Pacini Editore Srl 2020-03-01 /pmc/articles/PMC7315899/ /pubmed/32607478 http://dx.doi.org/10.36185/2532-1900-006 Text en ©2020 Gaetano Conte Academy - Mediterranean Society of Myology, Naples, Italy https://creativecommons.org/licenses/by-nc-nd/4.0/deed.en This is an open access article distributed in accordance with the CC-BY-NC-ND (Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International) license. The article can be used by giving appropriate credit and mentioning the license, but only for non-commercial purposes and only in the original version. For further information: https://creativecommons.org/licenses/by-nc-nd/4.0/deed.en |
spellingShingle | Case Report Sirico, Giusy Montisci, Andrea Secchi, Francesco Mantica, Massimo Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? |
title | Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? |
title_full | Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? |
title_fullStr | Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? |
title_full_unstemmed | Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? |
title_short | Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? |
title_sort | myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: icd yes or not? |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315899/ https://www.ncbi.nlm.nih.gov/pubmed/32607478 http://dx.doi.org/10.36185/2532-1900-006 |
work_keys_str_mv | AT siricogiusy myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot AT montisciandrea myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot AT secchifrancesco myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot AT manticamassimo myotonicdystrophytype1andhighventricularvulnerabilityattheelectrophysiologicalevaluationicdyesornot |