Cargando…
Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
Nanocomposites (NCs) of crosslinked polyaniline (CPA)-coated oxidized carbon nanomaterials (OXCNMs) were fabricated as a very sensitive and simple electrochemical sensor to be utilized in 2,4-dichlorophenol (2,4-DCPH) detection. CPA/OXCNMs NCs were prepared by chemical copolymerization of polyanilin...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7316237/ https://www.ncbi.nlm.nih.gov/pubmed/32584837 http://dx.doi.org/10.1371/journal.pone.0234815 |
_version_ | 1783550395976515584 |
---|---|
author | Katowah, Dina F. Mohammed, Gharam I. Al-Eryani, Dyab A. Sobahi, Tariq R. Hussein, Mahmoud A. |
author_facet | Katowah, Dina F. Mohammed, Gharam I. Al-Eryani, Dyab A. Sobahi, Tariq R. Hussein, Mahmoud A. |
author_sort | Katowah, Dina F. |
collection | PubMed |
description | Nanocomposites (NCs) of crosslinked polyaniline (CPA)-coated oxidized carbon nanomaterials (OXCNMs) were fabricated as a very sensitive and simple electrochemical sensor to be utilized in 2,4-dichlorophenol (2,4-DCPH) detection. CPA/OXCNMs NCs were prepared by chemical copolymerization of polyaniline with triphenylamine and p-phenylenediamine in the presence of OXCNMs. The CPA/GO-OXSWCNTNCs exhibited a higher affinity for the oxidation of chlorophenols compared to the glassy carbon electrode (GCE), CPA/GCE, and other NCs. Cyclic voltammetry was performed to investigate and assess the electrocatalytic oxidation of 2,4-DCPH on the modified GCE. The compound yielded a well-defined voltammetric response in a Britton-Robinson buffer (pH 5) at 0.54 V (vs. silver chloride electrode). Quantitative determination of 2,4-DCPH was performed by differential pulse voltammetry under optimal conditions in the concentration range of 0.05 to 1.2 nmol L(-1), and a linear calibration graph was obtained. The detection limit (S/N = 3) was found to be 4.2 nmol L(-1). In addition, the results demonstrated that the CPA/GO-OXSWCNTs/GCE sensor exhibited a strong anti-interference ability, reproducibility, and stability. The prepared CPA/GO-OXSWCNTs/GCE sensor was used to rapidly detect 2,4-DCPH with a high degree of sensitivity in fish farm water with proven levels of satisfactory recoveries. |
format | Online Article Text |
id | pubmed-7316237 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-73162372020-06-29 Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol Katowah, Dina F. Mohammed, Gharam I. Al-Eryani, Dyab A. Sobahi, Tariq R. Hussein, Mahmoud A. PLoS One Research Article Nanocomposites (NCs) of crosslinked polyaniline (CPA)-coated oxidized carbon nanomaterials (OXCNMs) were fabricated as a very sensitive and simple electrochemical sensor to be utilized in 2,4-dichlorophenol (2,4-DCPH) detection. CPA/OXCNMs NCs were prepared by chemical copolymerization of polyaniline with triphenylamine and p-phenylenediamine in the presence of OXCNMs. The CPA/GO-OXSWCNTNCs exhibited a higher affinity for the oxidation of chlorophenols compared to the glassy carbon electrode (GCE), CPA/GCE, and other NCs. Cyclic voltammetry was performed to investigate and assess the electrocatalytic oxidation of 2,4-DCPH on the modified GCE. The compound yielded a well-defined voltammetric response in a Britton-Robinson buffer (pH 5) at 0.54 V (vs. silver chloride electrode). Quantitative determination of 2,4-DCPH was performed by differential pulse voltammetry under optimal conditions in the concentration range of 0.05 to 1.2 nmol L(-1), and a linear calibration graph was obtained. The detection limit (S/N = 3) was found to be 4.2 nmol L(-1). In addition, the results demonstrated that the CPA/GO-OXSWCNTs/GCE sensor exhibited a strong anti-interference ability, reproducibility, and stability. The prepared CPA/GO-OXSWCNTs/GCE sensor was used to rapidly detect 2,4-DCPH with a high degree of sensitivity in fish farm water with proven levels of satisfactory recoveries. Public Library of Science 2020-06-25 /pmc/articles/PMC7316237/ /pubmed/32584837 http://dx.doi.org/10.1371/journal.pone.0234815 Text en © 2020 Katowah et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Katowah, Dina F. Mohammed, Gharam I. Al-Eryani, Dyab A. Sobahi, Tariq R. Hussein, Mahmoud A. Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol |
title | Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol |
title_full | Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol |
title_fullStr | Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol |
title_full_unstemmed | Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol |
title_short | Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol |
title_sort | rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7316237/ https://www.ncbi.nlm.nih.gov/pubmed/32584837 http://dx.doi.org/10.1371/journal.pone.0234815 |
work_keys_str_mv | AT katowahdinaf rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol AT mohammedgharami rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol AT aleryanidyaba rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol AT sobahitariqr rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol AT husseinmahmouda rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol |