Cargando…

Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol

Nanocomposites (NCs) of crosslinked polyaniline (CPA)-coated oxidized carbon nanomaterials (OXCNMs) were fabricated as a very sensitive and simple electrochemical sensor to be utilized in 2,4-dichlorophenol (2,4-DCPH) detection. CPA/OXCNMs NCs were prepared by chemical copolymerization of polyanilin...

Descripción completa

Detalles Bibliográficos
Autores principales: Katowah, Dina F., Mohammed, Gharam I., Al-Eryani, Dyab A., Sobahi, Tariq R., Hussein, Mahmoud A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7316237/
https://www.ncbi.nlm.nih.gov/pubmed/32584837
http://dx.doi.org/10.1371/journal.pone.0234815
_version_ 1783550395976515584
author Katowah, Dina F.
Mohammed, Gharam I.
Al-Eryani, Dyab A.
Sobahi, Tariq R.
Hussein, Mahmoud A.
author_facet Katowah, Dina F.
Mohammed, Gharam I.
Al-Eryani, Dyab A.
Sobahi, Tariq R.
Hussein, Mahmoud A.
author_sort Katowah, Dina F.
collection PubMed
description Nanocomposites (NCs) of crosslinked polyaniline (CPA)-coated oxidized carbon nanomaterials (OXCNMs) were fabricated as a very sensitive and simple electrochemical sensor to be utilized in 2,4-dichlorophenol (2,4-DCPH) detection. CPA/OXCNMs NCs were prepared by chemical copolymerization of polyaniline with triphenylamine and p-phenylenediamine in the presence of OXCNMs. The CPA/GO-OXSWCNTNCs exhibited a higher affinity for the oxidation of chlorophenols compared to the glassy carbon electrode (GCE), CPA/GCE, and other NCs. Cyclic voltammetry was performed to investigate and assess the electrocatalytic oxidation of 2,4-DCPH on the modified GCE. The compound yielded a well-defined voltammetric response in a Britton-Robinson buffer (pH 5) at 0.54 V (vs. silver chloride electrode). Quantitative determination of 2,4-DCPH was performed by differential pulse voltammetry under optimal conditions in the concentration range of 0.05 to 1.2 nmol L(-1), and a linear calibration graph was obtained. The detection limit (S/N = 3) was found to be 4.2 nmol L(-1). In addition, the results demonstrated that the CPA/GO-OXSWCNTs/GCE sensor exhibited a strong anti-interference ability, reproducibility, and stability. The prepared CPA/GO-OXSWCNTs/GCE sensor was used to rapidly detect 2,4-DCPH with a high degree of sensitivity in fish farm water with proven levels of satisfactory recoveries.
format Online
Article
Text
id pubmed-7316237
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-73162372020-06-29 Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol Katowah, Dina F. Mohammed, Gharam I. Al-Eryani, Dyab A. Sobahi, Tariq R. Hussein, Mahmoud A. PLoS One Research Article Nanocomposites (NCs) of crosslinked polyaniline (CPA)-coated oxidized carbon nanomaterials (OXCNMs) were fabricated as a very sensitive and simple electrochemical sensor to be utilized in 2,4-dichlorophenol (2,4-DCPH) detection. CPA/OXCNMs NCs were prepared by chemical copolymerization of polyaniline with triphenylamine and p-phenylenediamine in the presence of OXCNMs. The CPA/GO-OXSWCNTNCs exhibited a higher affinity for the oxidation of chlorophenols compared to the glassy carbon electrode (GCE), CPA/GCE, and other NCs. Cyclic voltammetry was performed to investigate and assess the electrocatalytic oxidation of 2,4-DCPH on the modified GCE. The compound yielded a well-defined voltammetric response in a Britton-Robinson buffer (pH 5) at 0.54 V (vs. silver chloride electrode). Quantitative determination of 2,4-DCPH was performed by differential pulse voltammetry under optimal conditions in the concentration range of 0.05 to 1.2 nmol L(-1), and a linear calibration graph was obtained. The detection limit (S/N = 3) was found to be 4.2 nmol L(-1). In addition, the results demonstrated that the CPA/GO-OXSWCNTs/GCE sensor exhibited a strong anti-interference ability, reproducibility, and stability. The prepared CPA/GO-OXSWCNTs/GCE sensor was used to rapidly detect 2,4-DCPH with a high degree of sensitivity in fish farm water with proven levels of satisfactory recoveries. Public Library of Science 2020-06-25 /pmc/articles/PMC7316237/ /pubmed/32584837 http://dx.doi.org/10.1371/journal.pone.0234815 Text en © 2020 Katowah et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Katowah, Dina F.
Mohammed, Gharam I.
Al-Eryani, Dyab A.
Sobahi, Tariq R.
Hussein, Mahmoud A.
Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
title Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
title_full Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
title_fullStr Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
title_full_unstemmed Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
title_short Rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
title_sort rapid and sensitive electrochemical sensor of cross-linked polyaniline/oxidized carbon nanomaterials core-shell nanocomposites for determination of 2,4-dichlorophenol
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7316237/
https://www.ncbi.nlm.nih.gov/pubmed/32584837
http://dx.doi.org/10.1371/journal.pone.0234815
work_keys_str_mv AT katowahdinaf rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol
AT mohammedgharami rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol
AT aleryanidyaba rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol
AT sobahitariqr rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol
AT husseinmahmouda rapidandsensitiveelectrochemicalsensorofcrosslinkedpolyanilineoxidizedcarbonnanomaterialscoreshellnanocompositesfordeterminationof24dichlorophenol