Cargando…

Coating doxycycline on titanium-based implants: Two in vivo studies

Regardless of the substantial progress in designing titanium-based dental implants and aseptic techniques, infection remains as the most common complication after implantation surgeries. Although, having a weakened immune system or systematic diseases is not seen as contraindicated for dental implan...

Descripción completa

Detalles Bibliográficos
Autores principales: Rahmati, Maryam, Lyngstadaas, Ståle Petter, Reseland, Janne E., Andersbakken, Ingrid, Haugland, Heidi Straume, López-Peña, Mónica, Cantalapiedra, Antonio Gonzalez, Guzon Muñoz, Fernando Maria, Haugen, Håvard Jostein
Formato: Online Artículo Texto
Lenguaje:English
Publicado: KeAi Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7317637/
https://www.ncbi.nlm.nih.gov/pubmed/32637743
http://dx.doi.org/10.1016/j.bioactmat.2020.05.007
_version_ 1783550674146951168
author Rahmati, Maryam
Lyngstadaas, Ståle Petter
Reseland, Janne E.
Andersbakken, Ingrid
Haugland, Heidi Straume
López-Peña, Mónica
Cantalapiedra, Antonio Gonzalez
Guzon Muñoz, Fernando Maria
Haugen, Håvard Jostein
author_facet Rahmati, Maryam
Lyngstadaas, Ståle Petter
Reseland, Janne E.
Andersbakken, Ingrid
Haugland, Heidi Straume
López-Peña, Mónica
Cantalapiedra, Antonio Gonzalez
Guzon Muñoz, Fernando Maria
Haugen, Håvard Jostein
author_sort Rahmati, Maryam
collection PubMed
description Regardless of the substantial progress in designing titanium-based dental implants and aseptic techniques, infection remains as the most common complication after implantation surgeries. Although, having a weakened immune system or systematic diseases is not seen as contraindicated for dental implants anymore, controlling the immune system is required to avoid surgical site infections after implantation. These patients have to control the surgical site infections by taking a high daily dose of oral antibiotics after dental implantation. The antibiotics oral administration has many side effects such as gastrointestinal symptoms, skin rashes and thrush. Coating antibiotics on the biomaterials surface could be a promising solution to reduce these disadvantages through locally releasing antibiotics in a controlled manner. The aim of this study was to investigate the effects of doxycycline coating layer on titanium-zirconium alloy surfaces in vitro and in vivo. In our previous studies, we demonstrated the chemical presence of doxycycline layer in vitro. In this study, we examined its physical presence using field emission scanning electron microscope and confocal microscope. We also analyzed its controlled released manner using Nano-Drop UV Vis spectrometer. After in vitro characterization of the coating layer, we evaluated its effects on the implant osseointegration in dogs and rabbits. The histological and histomorphometrical results exhibited no significant difference between doxycycline coated and uncoated groups regarding the implants osseointegration and biocompatibility for dental applications. Therefore, coating a doxycycline layer on TiZr implants could be favorable for reducing or removing the antibiotics oral administration after the implantation surgery.
format Online
Article
Text
id pubmed-7317637
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher KeAi Publishing
record_format MEDLINE/PubMed
spelling pubmed-73176372020-07-06 Coating doxycycline on titanium-based implants: Two in vivo studies Rahmati, Maryam Lyngstadaas, Ståle Petter Reseland, Janne E. Andersbakken, Ingrid Haugland, Heidi Straume López-Peña, Mónica Cantalapiedra, Antonio Gonzalez Guzon Muñoz, Fernando Maria Haugen, Håvard Jostein Bioact Mater Article Regardless of the substantial progress in designing titanium-based dental implants and aseptic techniques, infection remains as the most common complication after implantation surgeries. Although, having a weakened immune system or systematic diseases is not seen as contraindicated for dental implants anymore, controlling the immune system is required to avoid surgical site infections after implantation. These patients have to control the surgical site infections by taking a high daily dose of oral antibiotics after dental implantation. The antibiotics oral administration has many side effects such as gastrointestinal symptoms, skin rashes and thrush. Coating antibiotics on the biomaterials surface could be a promising solution to reduce these disadvantages through locally releasing antibiotics in a controlled manner. The aim of this study was to investigate the effects of doxycycline coating layer on titanium-zirconium alloy surfaces in vitro and in vivo. In our previous studies, we demonstrated the chemical presence of doxycycline layer in vitro. In this study, we examined its physical presence using field emission scanning electron microscope and confocal microscope. We also analyzed its controlled released manner using Nano-Drop UV Vis spectrometer. After in vitro characterization of the coating layer, we evaluated its effects on the implant osseointegration in dogs and rabbits. The histological and histomorphometrical results exhibited no significant difference between doxycycline coated and uncoated groups regarding the implants osseointegration and biocompatibility for dental applications. Therefore, coating a doxycycline layer on TiZr implants could be favorable for reducing or removing the antibiotics oral administration after the implantation surgery. KeAi Publishing 2020-06-22 /pmc/articles/PMC7317637/ /pubmed/32637743 http://dx.doi.org/10.1016/j.bioactmat.2020.05.007 Text en © 2020 [The Author/The Authors] http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rahmati, Maryam
Lyngstadaas, Ståle Petter
Reseland, Janne E.
Andersbakken, Ingrid
Haugland, Heidi Straume
López-Peña, Mónica
Cantalapiedra, Antonio Gonzalez
Guzon Muñoz, Fernando Maria
Haugen, Håvard Jostein
Coating doxycycline on titanium-based implants: Two in vivo studies
title Coating doxycycline on titanium-based implants: Two in vivo studies
title_full Coating doxycycline on titanium-based implants: Two in vivo studies
title_fullStr Coating doxycycline on titanium-based implants: Two in vivo studies
title_full_unstemmed Coating doxycycline on titanium-based implants: Two in vivo studies
title_short Coating doxycycline on titanium-based implants: Two in vivo studies
title_sort coating doxycycline on titanium-based implants: two in vivo studies
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7317637/
https://www.ncbi.nlm.nih.gov/pubmed/32637743
http://dx.doi.org/10.1016/j.bioactmat.2020.05.007
work_keys_str_mv AT rahmatimaryam coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT lyngstadaasstalepetter coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT reselandjannee coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT andersbakkeningrid coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT hauglandheidistraume coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT lopezpenamonica coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT cantalapiedraantoniogonzalez coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT guzonmunozfernandomaria coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies
AT haugenhavardjostein coatingdoxycyclineontitaniumbasedimplantstwoinvivostudies