Cargando…
Flanged intraocular lens fixation via 27‐gauge trocars using a double‐needle technique decreases surgical wounds without losing its therapeutic effect
PURPOSE: Intraocular lens (IOL) fixation using a sutureless 27‐gauge needle intrascleral IOL implantation technique requires six surgical wounds. We developed a modified technique using two 27‐gauge trocars for vitrectomy and indwelling flanged IOL haptics to reduce the number of surgical wounds. SE...
Autores principales: | Ishikawa, Hiroto, Fukuyama, Hisashi, Komuku, Yuki, Araki, Takashi, Gomi, Fumi |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7317769/ https://www.ncbi.nlm.nih.gov/pubmed/31736267 http://dx.doi.org/10.1111/aos.14313 |
Ejemplares similares
-
27-gauge trocar-assisted sutureless intraocular lens fixation
por: Jujo, Tatsuya, et al.
Publicado: (2021) -
Comparative analysis of metamorphopsia and aniseikonia after vitrectomy for epiretinal membrane, macular hole, or rhegmatogenous retinal detachment
por: Fukuyama, Hisashi, et al.
Publicado: (2020) -
Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique
por: Malach, Daniel S, et al.
Publicado: (2023) -
Trocar-assisted, flanged sutureless scleral-fixated intraocular lens implantation combined with silicone oil injection after penetrating keratoplasty surgery
por: Karadag, Remzi, et al.
Publicado: (2020) -
Predictive Biomarker for Progression Into the Sunset Glow Fundus of Vogt-Koyanagi-Harada Disease, Using Adaptive Binarization of Fundus Photographs
por: Komuku, Yuki, et al.
Publicado: (2020)