Cargando…

Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip

OBJECTIVES: This study aimed to investigate the reliability of 3‐dimensional (3D) ultrasound in screening for developmental dysplasia of the hip (DDH) by comparing the results with those of 2‐dimensional (2D) ultrasound. METHODS: One hundred five infants who were younger than 6 months were enrolled...

Descripción completa

Detalles Bibliográficos
Autores principales: Geng, Chenchen, Xu, Hongtao, Zhan, Xinfeng, Li, Li, Song, Qian, Zhang, Lu, Ge, Ling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7318168/
https://www.ncbi.nlm.nih.gov/pubmed/31814148
http://dx.doi.org/10.1002/jum.15193
_version_ 1783550783977947136
author Geng, Chenchen
Xu, Hongtao
Zhan, Xinfeng
Li, Li
Song, Qian
Zhang, Lu
Ge, Ling
author_facet Geng, Chenchen
Xu, Hongtao
Zhan, Xinfeng
Li, Li
Song, Qian
Zhang, Lu
Ge, Ling
author_sort Geng, Chenchen
collection PubMed
description OBJECTIVES: This study aimed to investigate the reliability of 3‐dimensional (3D) ultrasound in screening for developmental dysplasia of the hip (DDH) by comparing the results with those of 2‐dimensional (2D) ultrasound. METHODS: One hundred five infants who were younger than 6 months were enrolled in this study. All of the infants underwent 2D and 3D ultrasound scanning for DDH by novices and experts, and the images were graded by a lead expert. The scanning time and image grades were analyzed by Student t tests (P < .05). The consistency of the α angle measurement between the novices and experts was evaluated by the intraclass correlation coefficient (ICC). RESULTS: The 105 infants included 34 boys and 71 girls. On 2D scanning, there was agreement between the experts about the correct diagnosis, whereas in the novice group, 41 infants had misdiagnoses. There were no misdiagnoses with 3D scanning in either group. In the novice group, the mean image grades ± SD were 4.2 ± 1.3 (2D ultrasound) and 8.1 ± 0.7 (3D ultrasound; P < .05). In the expert group, the mean image grades were 7.4 ± 1.0 (2D ultrasound) and 8.2 ± 1.0 (3D ultrasound; P < .05). There was no statistically significant difference between the groups in the grades for 3D ultrasound (P = .83). The scanning time for 3D ultrasound was shorter than that for 2D ultrasound in both groups (P < .05). In the novice group, the ICC of the α angle between the 2D and 3D ultrasound results was 0.34, and in the expert group, it was 0.92. The ICCs were 0.35 and 0.84, respectively when comparing 2D and 3D ultrasound results in the groups. CONCLUSIONS: Three‐dimensional ultrasound required less time and showed greater inter‐rater reliability than 2D ultrasound for detecting DDH.
format Online
Article
Text
id pubmed-7318168
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-73181682020-06-29 Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip Geng, Chenchen Xu, Hongtao Zhan, Xinfeng Li, Li Song, Qian Zhang, Lu Ge, Ling J Ultrasound Med Original Research OBJECTIVES: This study aimed to investigate the reliability of 3‐dimensional (3D) ultrasound in screening for developmental dysplasia of the hip (DDH) by comparing the results with those of 2‐dimensional (2D) ultrasound. METHODS: One hundred five infants who were younger than 6 months were enrolled in this study. All of the infants underwent 2D and 3D ultrasound scanning for DDH by novices and experts, and the images were graded by a lead expert. The scanning time and image grades were analyzed by Student t tests (P < .05). The consistency of the α angle measurement between the novices and experts was evaluated by the intraclass correlation coefficient (ICC). RESULTS: The 105 infants included 34 boys and 71 girls. On 2D scanning, there was agreement between the experts about the correct diagnosis, whereas in the novice group, 41 infants had misdiagnoses. There were no misdiagnoses with 3D scanning in either group. In the novice group, the mean image grades ± SD were 4.2 ± 1.3 (2D ultrasound) and 8.1 ± 0.7 (3D ultrasound; P < .05). In the expert group, the mean image grades were 7.4 ± 1.0 (2D ultrasound) and 8.2 ± 1.0 (3D ultrasound; P < .05). There was no statistically significant difference between the groups in the grades for 3D ultrasound (P = .83). The scanning time for 3D ultrasound was shorter than that for 2D ultrasound in both groups (P < .05). In the novice group, the ICC of the α angle between the 2D and 3D ultrasound results was 0.34, and in the expert group, it was 0.92. The ICCs were 0.35 and 0.84, respectively when comparing 2D and 3D ultrasound results in the groups. CONCLUSIONS: Three‐dimensional ultrasound required less time and showed greater inter‐rater reliability than 2D ultrasound for detecting DDH. John Wiley & Sons, Inc. 2019-12-09 2020-06 /pmc/articles/PMC7318168/ /pubmed/31814148 http://dx.doi.org/10.1002/jum.15193 Text en © 2019 The Authors. Journal of Ultrasound in Medicine published by Wiley Periodicals, Inc. on behalf of the American Institute of Ultrasound in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Geng, Chenchen
Xu, Hongtao
Zhan, Xinfeng
Li, Li
Song, Qian
Zhang, Lu
Ge, Ling
Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip
title Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip
title_full Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip
title_fullStr Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip
title_full_unstemmed Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip
title_short Using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip
title_sort using 3‐dimensional ultrasound islice technology for the diagnosis of developmental dysplasia of the hip
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7318168/
https://www.ncbi.nlm.nih.gov/pubmed/31814148
http://dx.doi.org/10.1002/jum.15193
work_keys_str_mv AT gengchenchen using3dimensionalultrasoundislicetechnologyforthediagnosisofdevelopmentaldysplasiaofthehip
AT xuhongtao using3dimensionalultrasoundislicetechnologyforthediagnosisofdevelopmentaldysplasiaofthehip
AT zhanxinfeng using3dimensionalultrasoundislicetechnologyforthediagnosisofdevelopmentaldysplasiaofthehip
AT lili using3dimensionalultrasoundislicetechnologyforthediagnosisofdevelopmentaldysplasiaofthehip
AT songqian using3dimensionalultrasoundislicetechnologyforthediagnosisofdevelopmentaldysplasiaofthehip
AT zhanglu using3dimensionalultrasoundislicetechnologyforthediagnosisofdevelopmentaldysplasiaofthehip
AT geling using3dimensionalultrasoundislicetechnologyforthediagnosisofdevelopmentaldysplasiaofthehip