Cargando…
Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report
BACKGROUND: Percutaneous left atrial appendage (LAA) closure may reduce the risk of cardioembolic stroke in patients with non-valvular atrial fibrillation. Given the prophylactic nature of the procedure, identifying and managing complications are paramount. CASE SUMMARY: A 73-year-old man presented...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7319829/ https://www.ncbi.nlm.nih.gov/pubmed/32617484 http://dx.doi.org/10.1093/ehjcr/ytaa079 |
_version_ | 1783551126631612416 |
---|---|
author | Wilkins, Ben Carranza, Christian L Søndergaard, Lars De Backer, Ole |
author_facet | Wilkins, Ben Carranza, Christian L Søndergaard, Lars De Backer, Ole |
author_sort | Wilkins, Ben |
collection | PubMed |
description | BACKGROUND: Percutaneous left atrial appendage (LAA) closure may reduce the risk of cardioembolic stroke in patients with non-valvular atrial fibrillation. Given the prophylactic nature of the procedure, identifying and managing complications are paramount. CASE SUMMARY: A 73-year-old man presented 14 months after percutaneous LAA closure with syncope and acute pericardial tamponade which required surgical exploration and haemostasis; the most temporally remote account of this complication albeit amongst very few case reports. Tissue erosion by the Amplatzer™ Amulet™ LAA closure device (Abbott, Plymouth, MN, USA) was noted at two separate anatomical locations, corresponding to the device disc and lobe, which has not been described previously. DISCUSSION: This case report highlights the anatomical relationship between the LAA and its surrounding structures, and the importance of recognizing the risk of late device erosion. |
format | Online Article Text |
id | pubmed-7319829 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-73198292020-07-01 Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report Wilkins, Ben Carranza, Christian L Søndergaard, Lars De Backer, Ole Eur Heart J Case Rep Case Reports BACKGROUND: Percutaneous left atrial appendage (LAA) closure may reduce the risk of cardioembolic stroke in patients with non-valvular atrial fibrillation. Given the prophylactic nature of the procedure, identifying and managing complications are paramount. CASE SUMMARY: A 73-year-old man presented 14 months after percutaneous LAA closure with syncope and acute pericardial tamponade which required surgical exploration and haemostasis; the most temporally remote account of this complication albeit amongst very few case reports. Tissue erosion by the Amplatzer™ Amulet™ LAA closure device (Abbott, Plymouth, MN, USA) was noted at two separate anatomical locations, corresponding to the device disc and lobe, which has not been described previously. DISCUSSION: This case report highlights the anatomical relationship between the LAA and its surrounding structures, and the importance of recognizing the risk of late device erosion. Oxford University Press 2020-05-03 /pmc/articles/PMC7319829/ /pubmed/32617484 http://dx.doi.org/10.1093/ehjcr/ytaa079 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Reports Wilkins, Ben Carranza, Christian L Søndergaard, Lars De Backer, Ole Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report |
title | Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report |
title_full | Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report |
title_fullStr | Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report |
title_full_unstemmed | Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report |
title_short | Late presentation of left atrial appendage erosion and perforation by an Amplatzer™ Amulet™ closure device: a case report |
title_sort | late presentation of left atrial appendage erosion and perforation by an amplatzer™ amulet™ closure device: a case report |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7319829/ https://www.ncbi.nlm.nih.gov/pubmed/32617484 http://dx.doi.org/10.1093/ehjcr/ytaa079 |
work_keys_str_mv | AT wilkinsben latepresentationofleftatrialappendageerosionandperforationbyanamplatzeramuletclosuredeviceacasereport AT carranzachristianl latepresentationofleftatrialappendageerosionandperforationbyanamplatzeramuletclosuredeviceacasereport AT søndergaardlars latepresentationofleftatrialappendageerosionandperforationbyanamplatzeramuletclosuredeviceacasereport AT debackerole latepresentationofleftatrialappendageerosionandperforationbyanamplatzeramuletclosuredeviceacasereport |