Cargando…

Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report

BACKGROUND: Aortic root rupture is a severe complication of balloon-expandable transcatheter aortic valve replacement (TAVR). Although previous studies have revealed several risk factors for this complication, predicting this complication is occasionally difficult. CASE SUMMARY: A 78-year-old male p...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsuda, Masaki, Mizote, Isamu, Mukai, Takashi, Sakata, Yasushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7319835/
https://www.ncbi.nlm.nih.gov/pubmed/32617490
http://dx.doi.org/10.1093/ehjcr/ytaa073
_version_ 1783551128013635584
author Tsuda, Masaki
Mizote, Isamu
Mukai, Takashi
Sakata, Yasushi
author_facet Tsuda, Masaki
Mizote, Isamu
Mukai, Takashi
Sakata, Yasushi
author_sort Tsuda, Masaki
collection PubMed
description BACKGROUND: Aortic root rupture is a severe complication of balloon-expandable transcatheter aortic valve replacement (TAVR). Although previous studies have revealed several risk factors for this complication, predicting this complication is occasionally difficult. CASE SUMMARY: A 78-year-old male patient underwent TAVR via a transfemoral approach using a 29-mm balloon-expandable valve. No recognized risk factors for aortic root rupture existed in pre-procedural multi-detector computed tomography (MDCT) analysis. However, after the valve deployment, sudden haemodynamic collapse occurred. Transoesophageal echocardiography revealed pericardial effusion, which led to an immediate diagnosis of cardiac tamponade following aortic root rupture. Following pericardial drainage via a subxiphoid approach, the haemodynamics were immediately stabilized. After 10 days of close observation, the patient was discharged on Day 39 without additional problems. He was still alive at the 6-month follow-up without sequelae. DISCUSSION: Established risk factors for aortic root rupture include >20% area oversizing, bicuspid aortic valve, small annulus (<20 mm), shallow sinus of Valsalva (SOV) compared with the aortic annulus, and massive annular or subannular calcification. Our patient did not have any of the recognized risk factors for aortic root rupture, suggesting the existence of other factors. Pre-procedural MDCT showed a flat calcification orthogonal to the aortic root wall, and post-procedural MDCT revealed that this calcification penetrated the SOV with extravasation. Thus, we suggest that a flat calcification orthogonal to the aortic root wall might be an additional risk factor for aortic root rupture.
format Online
Article
Text
id pubmed-7319835
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-73198352020-07-01 Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report Tsuda, Masaki Mizote, Isamu Mukai, Takashi Sakata, Yasushi Eur Heart J Case Rep Case Reports BACKGROUND: Aortic root rupture is a severe complication of balloon-expandable transcatheter aortic valve replacement (TAVR). Although previous studies have revealed several risk factors for this complication, predicting this complication is occasionally difficult. CASE SUMMARY: A 78-year-old male patient underwent TAVR via a transfemoral approach using a 29-mm balloon-expandable valve. No recognized risk factors for aortic root rupture existed in pre-procedural multi-detector computed tomography (MDCT) analysis. However, after the valve deployment, sudden haemodynamic collapse occurred. Transoesophageal echocardiography revealed pericardial effusion, which led to an immediate diagnosis of cardiac tamponade following aortic root rupture. Following pericardial drainage via a subxiphoid approach, the haemodynamics were immediately stabilized. After 10 days of close observation, the patient was discharged on Day 39 without additional problems. He was still alive at the 6-month follow-up without sequelae. DISCUSSION: Established risk factors for aortic root rupture include >20% area oversizing, bicuspid aortic valve, small annulus (<20 mm), shallow sinus of Valsalva (SOV) compared with the aortic annulus, and massive annular or subannular calcification. Our patient did not have any of the recognized risk factors for aortic root rupture, suggesting the existence of other factors. Pre-procedural MDCT showed a flat calcification orthogonal to the aortic root wall, and post-procedural MDCT revealed that this calcification penetrated the SOV with extravasation. Thus, we suggest that a flat calcification orthogonal to the aortic root wall might be an additional risk factor for aortic root rupture. Oxford University Press 2020-05-26 /pmc/articles/PMC7319835/ /pubmed/32617490 http://dx.doi.org/10.1093/ehjcr/ytaa073 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Tsuda, Masaki
Mizote, Isamu
Mukai, Takashi
Sakata, Yasushi
Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report
title Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report
title_full Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report
title_fullStr Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report
title_full_unstemmed Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report
title_short Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report
title_sort aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7319835/
https://www.ncbi.nlm.nih.gov/pubmed/32617490
http://dx.doi.org/10.1093/ehjcr/ytaa073
work_keys_str_mv AT tsudamasaki aorticrootruptureduringballoonexpandabletranscatheteraorticvalvereplacementinapatientwithoutrecognizedriskfactorsforaorticrootruptureacasereport
AT mizoteisamu aorticrootruptureduringballoonexpandabletranscatheteraorticvalvereplacementinapatientwithoutrecognizedriskfactorsforaorticrootruptureacasereport
AT mukaitakashi aorticrootruptureduringballoonexpandabletranscatheteraorticvalvereplacementinapatientwithoutrecognizedriskfactorsforaorticrootruptureacasereport
AT sakatayasushi aorticrootruptureduringballoonexpandabletranscatheteraorticvalvereplacementinapatientwithoutrecognizedriskfactorsforaorticrootruptureacasereport