Cargando…

Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test

PURPOSE: To evaluate the biomechanical properties of the modified novel 2-hole monocortical plate fixation (2HMCPf) and traditional 4-hole monocortical plate fixation (4HMCPf) techniques in bilateral sagittal splitting osteotomy (BSSO) synthesis using a finite element analysis (FEA) and an in vitro...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Li-Ren, Chen, Chien-Chung, Jeng, Seng Feng, Chen, Yu-Ray, Hwang, Lain-Chyr, Lin, Ting-Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7320274/
https://www.ncbi.nlm.nih.gov/pubmed/32685538
http://dx.doi.org/10.1155/2020/8707389
_version_ 1783551206915833856
author Chang, Li-Ren
Chen, Chien-Chung
Jeng, Seng Feng
Chen, Yu-Ray
Hwang, Lain-Chyr
Lin, Ting-Sheng
author_facet Chang, Li-Ren
Chen, Chien-Chung
Jeng, Seng Feng
Chen, Yu-Ray
Hwang, Lain-Chyr
Lin, Ting-Sheng
author_sort Chang, Li-Ren
collection PubMed
description PURPOSE: To evaluate the biomechanical properties of the modified novel 2-hole monocortical plate fixation (2HMCPf) and traditional 4-hole monocortical plate fixation (4HMCPf) techniques in bilateral sagittal splitting osteotomy (BSSO) synthesis using a finite element analysis (FEA) and an in vitro biomechanical test with the application of a shearing loading force on a sawbone mandible model. MATERIALS AND METHODS: A three-dimensional mandible models were generated using the geometry obtained from the computerized tomography image of a sawbone mandible. Plates and screws were generated and combined with the mandible in a CAD environment. The 2HMCPf and traditional 4HMCPf techniques for BSSO osteosynthesis were then analyzed under the occlusal load using the FEA. An in vitro biomechanical test was executed to verify the result of FEA. The force on fixation failure and pattern of failure were recorded. RESULTS: The results revealed that the von Mises Stress on the mandible cortical bone (75.98 MPa) and the screw/plate (457.19 MPa) of the 2HMCPf group was lower than that of the 4HMCPf group (987.68 MPa, 1781.59 MPa). The stress concentrated on the central region of the 4HMCPf group and the distal set of the 2HMCPf group. In vitro study using the sawbone mandible model showed mechanical failure at the region of the proximal segment near the osteotomy site with the 4HMCPf group (average 32.198 N) but no failure on the fixation sites with the 2HMCPf group. Instead, the mandible sawbone fractured on the condyle neck region (average 44.953 N). CONCLUSION: From the biomechanical perspective, we proved that the 2HMCPf method was able to withstand a higher shearing loading force than the 4HMCPf fixation method in BSSO osteosynthesis.
format Online
Article
Text
id pubmed-7320274
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-73202742020-07-17 Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test Chang, Li-Ren Chen, Chien-Chung Jeng, Seng Feng Chen, Yu-Ray Hwang, Lain-Chyr Lin, Ting-Sheng Biomed Res Int Research Article PURPOSE: To evaluate the biomechanical properties of the modified novel 2-hole monocortical plate fixation (2HMCPf) and traditional 4-hole monocortical plate fixation (4HMCPf) techniques in bilateral sagittal splitting osteotomy (BSSO) synthesis using a finite element analysis (FEA) and an in vitro biomechanical test with the application of a shearing loading force on a sawbone mandible model. MATERIALS AND METHODS: A three-dimensional mandible models were generated using the geometry obtained from the computerized tomography image of a sawbone mandible. Plates and screws were generated and combined with the mandible in a CAD environment. The 2HMCPf and traditional 4HMCPf techniques for BSSO osteosynthesis were then analyzed under the occlusal load using the FEA. An in vitro biomechanical test was executed to verify the result of FEA. The force on fixation failure and pattern of failure were recorded. RESULTS: The results revealed that the von Mises Stress on the mandible cortical bone (75.98 MPa) and the screw/plate (457.19 MPa) of the 2HMCPf group was lower than that of the 4HMCPf group (987.68 MPa, 1781.59 MPa). The stress concentrated on the central region of the 4HMCPf group and the distal set of the 2HMCPf group. In vitro study using the sawbone mandible model showed mechanical failure at the region of the proximal segment near the osteotomy site with the 4HMCPf group (average 32.198 N) but no failure on the fixation sites with the 2HMCPf group. Instead, the mandible sawbone fractured on the condyle neck region (average 44.953 N). CONCLUSION: From the biomechanical perspective, we proved that the 2HMCPf method was able to withstand a higher shearing loading force than the 4HMCPf fixation method in BSSO osteosynthesis. Hindawi 2020-06-17 /pmc/articles/PMC7320274/ /pubmed/32685538 http://dx.doi.org/10.1155/2020/8707389 Text en Copyright © 2020 Li-Ren Chang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chang, Li-Ren
Chen, Chien-Chung
Jeng, Seng Feng
Chen, Yu-Ray
Hwang, Lain-Chyr
Lin, Ting-Sheng
Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test
title Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test
title_full Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test
title_fullStr Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test
title_full_unstemmed Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test
title_short Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test
title_sort investigation of a modified novel technique in bilateral sagittal splitting osteotomy fixation: finite element analysis and in vitro biomechanical test
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7320274/
https://www.ncbi.nlm.nih.gov/pubmed/32685538
http://dx.doi.org/10.1155/2020/8707389
work_keys_str_mv AT changliren investigationofamodifiednoveltechniqueinbilateralsagittalsplittingosteotomyfixationfiniteelementanalysisandinvitrobiomechanicaltest
AT chenchienchung investigationofamodifiednoveltechniqueinbilateralsagittalsplittingosteotomyfixationfiniteelementanalysisandinvitrobiomechanicaltest
AT jengsengfeng investigationofamodifiednoveltechniqueinbilateralsagittalsplittingosteotomyfixationfiniteelementanalysisandinvitrobiomechanicaltest
AT chenyuray investigationofamodifiednoveltechniqueinbilateralsagittalsplittingosteotomyfixationfiniteelementanalysisandinvitrobiomechanicaltest
AT hwanglainchyr investigationofamodifiednoveltechniqueinbilateralsagittalsplittingosteotomyfixationfiniteelementanalysisandinvitrobiomechanicaltest
AT lintingsheng investigationofamodifiednoveltechniqueinbilateralsagittalsplittingosteotomyfixationfiniteelementanalysisandinvitrobiomechanicaltest