Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study

BACKGROUND: Traditional methods for minimally invasive internal fixation (MIIF) of calcaneal fractures require extensive intraoperative fluoroscopy, and fracture recovery is usually not ideal. We developed a new surgical procedure using digital surgical simulation and constructed a patient-specific...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chenggong, Xu, Can, Li, Mingqing, Li, Hui, Xiao, Han, Zhong, Da, Liu, Hua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7321547/
https://www.ncbi.nlm.nih.gov/pubmed/32593302
http://dx.doi.org/10.1186/s12891-020-03439-3
_version_ 1783551492318298112
author Wang, Chenggong
Xu, Can
Li, Mingqing
Li, Hui
Xiao, Han
Zhong, Da
Liu, Hua
author_facet Wang, Chenggong
Xu, Can
Li, Mingqing
Li, Hui
Xiao, Han
Zhong, Da
Liu, Hua
author_sort Wang, Chenggong
collection PubMed
description BACKGROUND: Traditional methods for minimally invasive internal fixation (MIIF) of calcaneal fractures require extensive intraoperative fluoroscopy, and fracture recovery is usually not ideal. We developed a new surgical procedure using digital surgical simulation and constructed a patient-specific instrument (PSI) for calcaneal fracture that we used during the operation. This study investigated whether PSI-assisted MIIF of calcaneal fracture enables rapid and accurate execution of the preoperative plan. METHODS: We retrospectively analyzed patients with Sanders type III or IV fresh calcaneal fractures who had undergone PSI-assisted MIIF at our hospital from January 2016 to December 2018. We analyzed perioperative data including intraoperative fluoroscopy time, concurrence of internal fixation actual usage (IFAU) with the preoperative plan, surgery time, and complications. We also compared pre- and postoperative actual measurements from X-ray radiographs and computed tomography images including Böhler, Gissane, and calcaneus valgus angles; subtalar joint width; and calcaneal volume overlap ratio with the preoperative design. All patients had been followed up and their American Orthopedic Foot and Ankle Score (AOFAS) score was available. RESULTS: Mean intraoperative fluoroscopy time was 3.95 ± 1.78 h; IFAU in 16 patients (16 ft) was the same as the preoperative plan; mean surgery time was 28.16 ± 10.70 min; and none of the patients developed complications. Böhler, Gissane, and calcaneus valgus angles and subtalar joint width did not differ between pre- and postoperative plans; however, the actual preoperative values of each of these parameters differed significantly from those measured postoperatively. The calcaneal volume overlap ratio with the preoperative design was 91.2% ± 2.3%. AOFAS scores increased with time, with significant differences in the score at each time point. CONCLUSIONS: The newly developed PSI-assisted calcaneal fracture MIIF method can rapidly and accurately execute the preoperative plan.
format Online
Article
Text
id pubmed-7321547
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73215472020-06-29 Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study Wang, Chenggong Xu, Can Li, Mingqing Li, Hui Xiao, Han Zhong, Da Liu, Hua BMC Musculoskelet Disord Research Article BACKGROUND: Traditional methods for minimally invasive internal fixation (MIIF) of calcaneal fractures require extensive intraoperative fluoroscopy, and fracture recovery is usually not ideal. We developed a new surgical procedure using digital surgical simulation and constructed a patient-specific instrument (PSI) for calcaneal fracture that we used during the operation. This study investigated whether PSI-assisted MIIF of calcaneal fracture enables rapid and accurate execution of the preoperative plan. METHODS: We retrospectively analyzed patients with Sanders type III or IV fresh calcaneal fractures who had undergone PSI-assisted MIIF at our hospital from January 2016 to December 2018. We analyzed perioperative data including intraoperative fluoroscopy time, concurrence of internal fixation actual usage (IFAU) with the preoperative plan, surgery time, and complications. We also compared pre- and postoperative actual measurements from X-ray radiographs and computed tomography images including Böhler, Gissane, and calcaneus valgus angles; subtalar joint width; and calcaneal volume overlap ratio with the preoperative design. All patients had been followed up and their American Orthopedic Foot and Ankle Score (AOFAS) score was available. RESULTS: Mean intraoperative fluoroscopy time was 3.95 ± 1.78 h; IFAU in 16 patients (16 ft) was the same as the preoperative plan; mean surgery time was 28.16 ± 10.70 min; and none of the patients developed complications. Böhler, Gissane, and calcaneus valgus angles and subtalar joint width did not differ between pre- and postoperative plans; however, the actual preoperative values of each of these parameters differed significantly from those measured postoperatively. The calcaneal volume overlap ratio with the preoperative design was 91.2% ± 2.3%. AOFAS scores increased with time, with significant differences in the score at each time point. CONCLUSIONS: The newly developed PSI-assisted calcaneal fracture MIIF method can rapidly and accurately execute the preoperative plan. BioMed Central 2020-06-27 /pmc/articles/PMC7321547/ /pubmed/32593302 http://dx.doi.org/10.1186/s12891-020-03439-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Wang, Chenggong
Xu, Can
Li, Mingqing
Li, Hui
Xiao, Han
Zhong, Da
Liu, Hua
Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study
title Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study
title_full Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study
title_fullStr Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study
title_full_unstemmed Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study
title_short Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study
title_sort patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: a retrospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7321547/
https://www.ncbi.nlm.nih.gov/pubmed/32593302
http://dx.doi.org/10.1186/s12891-020-03439-3
work_keys_str_mv AT wangchenggong patientspecificinstrumentassistedminimallyinvasiveinternalfixationofcalcanealfractureforrapidandaccurateexecutionofapreoperativeplanaretrospectivestudy
AT xucan patientspecificinstrumentassistedminimallyinvasiveinternalfixationofcalcanealfractureforrapidandaccurateexecutionofapreoperativeplanaretrospectivestudy
AT limingqing patientspecificinstrumentassistedminimallyinvasiveinternalfixationofcalcanealfractureforrapidandaccurateexecutionofapreoperativeplanaretrospectivestudy
AT lihui patientspecificinstrumentassistedminimallyinvasiveinternalfixationofcalcanealfractureforrapidandaccurateexecutionofapreoperativeplanaretrospectivestudy
AT xiaohan patientspecificinstrumentassistedminimallyinvasiveinternalfixationofcalcanealfractureforrapidandaccurateexecutionofapreoperativeplanaretrospectivestudy
AT zhongda patientspecificinstrumentassistedminimallyinvasiveinternalfixationofcalcanealfractureforrapidandaccurateexecutionofapreoperativeplanaretrospectivestudy
AT liuhua patientspecificinstrumentassistedminimallyinvasiveinternalfixationofcalcanealfractureforrapidandaccurateexecutionofapreoperativeplanaretrospectivestudy