Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging
BACKGROUND: Simultaneous cardiovascular imaging with positron emission tomography (PET) and magnetic resonance imaging (MRI) requires tools such as radio frequency (RF) phased arrays to achieve high temporal and spatial resolution in the MRI, as well as accurate quantification of PET. Today, high-de...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7324084/ https://www.ncbi.nlm.nih.gov/pubmed/32626841 http://dx.doi.org/10.1186/s41824-020-00076-w |
_version_ | 1783551876943314944 |
---|---|
author | Farag, Adam Thompson, R. Terry Thiessen, Jonathan D. Biernaski, Heather Prato, Frank S. Théberge, Jean |
author_facet | Farag, Adam Thompson, R. Terry Thiessen, Jonathan D. Biernaski, Heather Prato, Frank S. Théberge, Jean |
author_sort | Farag, Adam |
collection | PubMed |
description | BACKGROUND: Simultaneous cardiovascular imaging with positron emission tomography (PET) and magnetic resonance imaging (MRI) requires tools such as radio frequency (RF) phased arrays to achieve high temporal and spatial resolution in the MRI, as well as accurate quantification of PET. Today, high-density phased arrays (> 16 channels) used for cardiovascular PET/MRI are not designed to achieve low PET attenuation, and correcting the PET attenuation they cause requires off-line reconstruction, extra time and resources. PURPOSE: Motivated by previous work assessing the MRI performance of a novel prospectively designed 32-channel phased array, this study assessed the PET image quality with this array in place. Guided by NEMA standards, PET performance was measured using global PET counts, regional background variation (BV), contrast recovery (CR) and contrast-to-noise ratio (CNR) for both the novel array and standard arrays (mMR 12-channel and MRI 32-channel). Nonattenuation-corrected (NAC) data from all arrays (and each part of the array) were processed and compared to no-array, and relative percentage difference (RPD) of the global means was estimated and reported for each part of the arrays. Attenuation correction (AC) of PET images (water in the phantom) using two approaches, MR-based AC map (MRAC) and dual-energy CT-based map (DCTAC), was performed, and RPD compared for each part of the arrays. Percent mean attenuation within regions of interests of the phantom images from each array were compared using a two-way analysis of variance (ANOVA). RESULTS: The NAC data of the anterior part of the novel array recorded the least PET attenuation (≤ 2%); while the full novel array (anterior and posterior together) AC data, produced by MRAC and DCTAC approaches, recorded attenuation of 1.5 ± 2.9% and 0.0 ± 2.5%, respectively. The novel array PET count loss was significantly lower (p = 0.001) than those caused by the standard arrays. CONCLUSIONS: Results of this novel 32-channel cardiac array PET performance evaluation, together with its previously reported MRI performance assessment, suggest the novel array to be a strong alternative to the standard arrays currently used for cardiovascular hybrid PET/MRI imaging. It enables accurate PET quantification and high-temporal and spatial resolution for MR imaging. |
format | Online Article Text |
id | pubmed-7324084 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-73240842020-07-02 Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging Farag, Adam Thompson, R. Terry Thiessen, Jonathan D. Biernaski, Heather Prato, Frank S. Théberge, Jean Eur J Hybrid Imaging Original Article BACKGROUND: Simultaneous cardiovascular imaging with positron emission tomography (PET) and magnetic resonance imaging (MRI) requires tools such as radio frequency (RF) phased arrays to achieve high temporal and spatial resolution in the MRI, as well as accurate quantification of PET. Today, high-density phased arrays (> 16 channels) used for cardiovascular PET/MRI are not designed to achieve low PET attenuation, and correcting the PET attenuation they cause requires off-line reconstruction, extra time and resources. PURPOSE: Motivated by previous work assessing the MRI performance of a novel prospectively designed 32-channel phased array, this study assessed the PET image quality with this array in place. Guided by NEMA standards, PET performance was measured using global PET counts, regional background variation (BV), contrast recovery (CR) and contrast-to-noise ratio (CNR) for both the novel array and standard arrays (mMR 12-channel and MRI 32-channel). Nonattenuation-corrected (NAC) data from all arrays (and each part of the array) were processed and compared to no-array, and relative percentage difference (RPD) of the global means was estimated and reported for each part of the arrays. Attenuation correction (AC) of PET images (water in the phantom) using two approaches, MR-based AC map (MRAC) and dual-energy CT-based map (DCTAC), was performed, and RPD compared for each part of the arrays. Percent mean attenuation within regions of interests of the phantom images from each array were compared using a two-way analysis of variance (ANOVA). RESULTS: The NAC data of the anterior part of the novel array recorded the least PET attenuation (≤ 2%); while the full novel array (anterior and posterior together) AC data, produced by MRAC and DCTAC approaches, recorded attenuation of 1.5 ± 2.9% and 0.0 ± 2.5%, respectively. The novel array PET count loss was significantly lower (p = 0.001) than those caused by the standard arrays. CONCLUSIONS: Results of this novel 32-channel cardiac array PET performance evaluation, together with its previously reported MRI performance assessment, suggest the novel array to be a strong alternative to the standard arrays currently used for cardiovascular hybrid PET/MRI imaging. It enables accurate PET quantification and high-temporal and spatial resolution for MR imaging. Springer International Publishing 2020-05-12 /pmc/articles/PMC7324084/ /pubmed/32626841 http://dx.doi.org/10.1186/s41824-020-00076-w Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Farag, Adam Thompson, R. Terry Thiessen, Jonathan D. Biernaski, Heather Prato, Frank S. Théberge, Jean Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging |
title | Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging |
title_full | Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging |
title_fullStr | Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging |
title_full_unstemmed | Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging |
title_short | Evaluation of 511 keV photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid PET/MRI imaging |
title_sort | evaluation of 511 kev photon attenuation by a novel 32-channel phased array prospectively designed for cardiovascular hybrid pet/mri imaging |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7324084/ https://www.ncbi.nlm.nih.gov/pubmed/32626841 http://dx.doi.org/10.1186/s41824-020-00076-w |
work_keys_str_mv | AT faragadam evaluationof511kevphotonattenuationbyanovel32channelphasedarrayprospectivelydesignedforcardiovascularhybridpetmriimaging AT thompsonrterry evaluationof511kevphotonattenuationbyanovel32channelphasedarrayprospectivelydesignedforcardiovascularhybridpetmriimaging AT thiessenjonathand evaluationof511kevphotonattenuationbyanovel32channelphasedarrayprospectivelydesignedforcardiovascularhybridpetmriimaging AT biernaskiheather evaluationof511kevphotonattenuationbyanovel32channelphasedarrayprospectivelydesignedforcardiovascularhybridpetmriimaging AT pratofranks evaluationof511kevphotonattenuationbyanovel32channelphasedarrayprospectivelydesignedforcardiovascularhybridpetmriimaging AT thebergejean evaluationof511kevphotonattenuationbyanovel32channelphasedarrayprospectivelydesignedforcardiovascularhybridpetmriimaging |