Cargando…
Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat
Gel technology is widely used for blood typing in human medicine. It has a number of advantages over routine tube testing, including standardization, stability, smaller sample volume, ease of performance and analysis, and speed. The aim of this study was to evaluate feline blood typing using the gel...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7324631/ https://www.ncbi.nlm.nih.gov/pubmed/32656250 http://dx.doi.org/10.3389/fvets.2020.00312 |
_version_ | 1783551978364731392 |
---|---|
author | Spada, Eva Perego, Roberta Baggiani, Luciana Proverbio, Daniela |
author_facet | Spada, Eva Perego, Roberta Baggiani, Luciana Proverbio, Daniela |
author_sort | Spada, Eva |
collection | PubMed |
description | Gel technology is widely used for blood typing in human medicine. It has a number of advantages over routine tube testing, including standardization, stability, smaller sample volume, ease of performance and analysis, and speed. The aim of this study was to evaluate feline blood typing using the gel column technique. TUBE agglutination typing was performed in 143 feline blood samples from blood donors and recipients, healthy and sick patients, and whole-blood units anticoagulated with ethylenediamine tetraacetic acid or citrate phosphate dextrose adenine. Plasma from type B cats was used as anti-A reagent, Triticum vulgaris lectin as anti-B reagent, and the control was saline solution. Agglutination in backtyping of types B and AB samples with type A red blood cells (RBCs) was used to confirm whether the samples were type B (presence of alloantibodies) or type AB (absence of alloantibodies). Blood typing in a neutral gel column technique (GEL) using the same anti-A and anti-B reagents was performed on duplicate samples. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value, negative predictive value, overall accuracy, and Cohen κ coefficient (κ) for GEL were calculated, with TUBE considered the gold standard technique. Of 143 samples typed with TUBE, 98 (68.5%) were type A, 25 (17.5%,) type B, and 20 (14.0%) type AB. Backtyping confirmed the categorization of all types B and AB samples. Of these samples, gel testing produced 115 (80.4%) concordant results; a mixed-field agglutination pattern (layers of RBCs at both the top and at the bottom of the gel in either the A or B gel column) was seen in 27 samples, and one type B sample was misidentified as type AB. If the mixed-field pattern was interpreted as a negative result, 141/143 (98.6%) samples showed concordant results with an overall accuracy of the GEL of 100.0% for type A, 98.9% for type B, and 99.1% for type AB. Strength of agreement was very good (κ = 0.97). When the same anti-A and anti-B reagents are used, GEL is a sensitive and specific method for blood typing feline samples. Until additional studies have been performed, mixed-field patterns obtained in GEL testing should be classified as negative results. |
format | Online Article Text |
id | pubmed-7324631 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-73246312020-07-10 Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat Spada, Eva Perego, Roberta Baggiani, Luciana Proverbio, Daniela Front Vet Sci Veterinary Science Gel technology is widely used for blood typing in human medicine. It has a number of advantages over routine tube testing, including standardization, stability, smaller sample volume, ease of performance and analysis, and speed. The aim of this study was to evaluate feline blood typing using the gel column technique. TUBE agglutination typing was performed in 143 feline blood samples from blood donors and recipients, healthy and sick patients, and whole-blood units anticoagulated with ethylenediamine tetraacetic acid or citrate phosphate dextrose adenine. Plasma from type B cats was used as anti-A reagent, Triticum vulgaris lectin as anti-B reagent, and the control was saline solution. Agglutination in backtyping of types B and AB samples with type A red blood cells (RBCs) was used to confirm whether the samples were type B (presence of alloantibodies) or type AB (absence of alloantibodies). Blood typing in a neutral gel column technique (GEL) using the same anti-A and anti-B reagents was performed on duplicate samples. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value, negative predictive value, overall accuracy, and Cohen κ coefficient (κ) for GEL were calculated, with TUBE considered the gold standard technique. Of 143 samples typed with TUBE, 98 (68.5%) were type A, 25 (17.5%,) type B, and 20 (14.0%) type AB. Backtyping confirmed the categorization of all types B and AB samples. Of these samples, gel testing produced 115 (80.4%) concordant results; a mixed-field agglutination pattern (layers of RBCs at both the top and at the bottom of the gel in either the A or B gel column) was seen in 27 samples, and one type B sample was misidentified as type AB. If the mixed-field pattern was interpreted as a negative result, 141/143 (98.6%) samples showed concordant results with an overall accuracy of the GEL of 100.0% for type A, 98.9% for type B, and 99.1% for type AB. Strength of agreement was very good (κ = 0.97). When the same anti-A and anti-B reagents are used, GEL is a sensitive and specific method for blood typing feline samples. Until additional studies have been performed, mixed-field patterns obtained in GEL testing should be classified as negative results. Frontiers Media S.A. 2020-06-23 /pmc/articles/PMC7324631/ /pubmed/32656250 http://dx.doi.org/10.3389/fvets.2020.00312 Text en Copyright © 2020 Spada, Perego, Baggiani and Proverbio. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Veterinary Science Spada, Eva Perego, Roberta Baggiani, Luciana Proverbio, Daniela Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat |
title | Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat |
title_full | Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat |
title_fullStr | Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat |
title_full_unstemmed | Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat |
title_short | Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat |
title_sort | comparison of conventional tube and gel-based agglutination tests for ab system blood typing in cat |
topic | Veterinary Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7324631/ https://www.ncbi.nlm.nih.gov/pubmed/32656250 http://dx.doi.org/10.3389/fvets.2020.00312 |
work_keys_str_mv | AT spadaeva comparisonofconventionaltubeandgelbasedagglutinationtestsforabsystembloodtypingincat AT peregoroberta comparisonofconventionaltubeandgelbasedagglutinationtestsforabsystembloodtypingincat AT baggianiluciana comparisonofconventionaltubeandgelbasedagglutinationtestsforabsystembloodtypingincat AT proverbiodaniela comparisonofconventionaltubeandgelbasedagglutinationtestsforabsystembloodtypingincat |