Cargando…

Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis

BACKGROUND: Fixing a tibial eminence fracture with a tri-pulley is a new technique. The purpose of this study was to present the early clinical outcome of arthroscopic tri-pulley suture fixation for tibial eminence fractures in children. METHODS: Twenty-one pediatric patients with type II or type II...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Liang, Zhang, Li, Zheng, Jiang, Ren, Bo, Kang, Xin, Zhang, Xian, Dang, Xiaoqian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7325093/
https://www.ncbi.nlm.nih.gov/pubmed/32600299
http://dx.doi.org/10.1186/s12891-020-03421-z
_version_ 1783552088613060608
author Zhang, Liang
Zhang, Li
Zheng, Jiang
Ren, Bo
Kang, Xin
Zhang, Xian
Dang, Xiaoqian
author_facet Zhang, Liang
Zhang, Li
Zheng, Jiang
Ren, Bo
Kang, Xin
Zhang, Xian
Dang, Xiaoqian
author_sort Zhang, Liang
collection PubMed
description BACKGROUND: Fixing a tibial eminence fracture with a tri-pulley is a new technique. The purpose of this study was to present the early clinical outcome of arthroscopic tri-pulley suture fixation for tibial eminence fractures in children. METHODS: Twenty-one pediatric patients with type II or type III anterior tibial eminence fractures were included in this retrospective study. All Patients underwent surgical fixation by tri-pulley technology and were followed up for at least 24 months. They were evaluated preoperatively and postoperatively by physical, X-ray, and computed tomography (CT) examination and subjectively with the International Knee Documentation Committee (IKDC), and Lysholm questionnaires. RESULTS: The patients included 12 males and 9 females; mean age, 12.5 years (range, 8 ~ 16 years). They were followed-up for a median of 27 months (range, 24 ~ 39 months). We did not find post-operative instability in any of the patients by physical examination. The KT-2000 difference of both knees decreased from 9.3 ± 1.2 mm preoperatively to 2.6 ± 0.8 mm 24 months postoperatively (P < 0.001); the IKDC subjective knee evaluation score improved from 43.1 ± 13.2 preoperatively to 83.8 ± 6.3 postoperatively (P < 0.001); and Lysholm improved from 48.3 ± 6.21 to 87.1 ± 9.8 (P < 0.001). No unhealed fractures or epiphyseal damage were reported in the postoperative X-ray and CT. CONCLUSIONS: Arthroscopic tri-pulley fixation technology may provide a suitable technique for repair of tibial eminence fractures in skeletally immature patients. LEVEL OF EVIDENCE: Case series; Level of evidence IV.
format Online
Article
Text
id pubmed-7325093
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73250932020-06-30 Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis Zhang, Liang Zhang, Li Zheng, Jiang Ren, Bo Kang, Xin Zhang, Xian Dang, Xiaoqian BMC Musculoskelet Disord Research Article BACKGROUND: Fixing a tibial eminence fracture with a tri-pulley is a new technique. The purpose of this study was to present the early clinical outcome of arthroscopic tri-pulley suture fixation for tibial eminence fractures in children. METHODS: Twenty-one pediatric patients with type II or type III anterior tibial eminence fractures were included in this retrospective study. All Patients underwent surgical fixation by tri-pulley technology and were followed up for at least 24 months. They were evaluated preoperatively and postoperatively by physical, X-ray, and computed tomography (CT) examination and subjectively with the International Knee Documentation Committee (IKDC), and Lysholm questionnaires. RESULTS: The patients included 12 males and 9 females; mean age, 12.5 years (range, 8 ~ 16 years). They were followed-up for a median of 27 months (range, 24 ~ 39 months). We did not find post-operative instability in any of the patients by physical examination. The KT-2000 difference of both knees decreased from 9.3 ± 1.2 mm preoperatively to 2.6 ± 0.8 mm 24 months postoperatively (P < 0.001); the IKDC subjective knee evaluation score improved from 43.1 ± 13.2 preoperatively to 83.8 ± 6.3 postoperatively (P < 0.001); and Lysholm improved from 48.3 ± 6.21 to 87.1 ± 9.8 (P < 0.001). No unhealed fractures or epiphyseal damage were reported in the postoperative X-ray and CT. CONCLUSIONS: Arthroscopic tri-pulley fixation technology may provide a suitable technique for repair of tibial eminence fractures in skeletally immature patients. LEVEL OF EVIDENCE: Case series; Level of evidence IV. BioMed Central 2020-06-29 /pmc/articles/PMC7325093/ /pubmed/32600299 http://dx.doi.org/10.1186/s12891-020-03421-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Zhang, Liang
Zhang, Li
Zheng, Jiang
Ren, Bo
Kang, Xin
Zhang, Xian
Dang, Xiaoqian
Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis
title Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis
title_full Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis
title_fullStr Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis
title_full_unstemmed Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis
title_short Arthroscopic tri-pulley Technology reduction and internal fixation of pediatric Tibial Eminence fracture: a retrospective analysis
title_sort arthroscopic tri-pulley technology reduction and internal fixation of pediatric tibial eminence fracture: a retrospective analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7325093/
https://www.ncbi.nlm.nih.gov/pubmed/32600299
http://dx.doi.org/10.1186/s12891-020-03421-z
work_keys_str_mv AT zhangliang arthroscopictripulleytechnologyreductionandinternalfixationofpediatrictibialeminencefracturearetrospectiveanalysis
AT zhangli arthroscopictripulleytechnologyreductionandinternalfixationofpediatrictibialeminencefracturearetrospectiveanalysis
AT zhengjiang arthroscopictripulleytechnologyreductionandinternalfixationofpediatrictibialeminencefracturearetrospectiveanalysis
AT renbo arthroscopictripulleytechnologyreductionandinternalfixationofpediatrictibialeminencefracturearetrospectiveanalysis
AT kangxin arthroscopictripulleytechnologyreductionandinternalfixationofpediatrictibialeminencefracturearetrospectiveanalysis
AT zhangxian arthroscopictripulleytechnologyreductionandinternalfixationofpediatrictibialeminencefracturearetrospectiveanalysis
AT dangxiaoqian arthroscopictripulleytechnologyreductionandinternalfixationofpediatrictibialeminencefracturearetrospectiveanalysis