Cargando…
Short-echo-time magnitude image derived from quantitative susceptibility mapping could resemble neuromelanin-sensitive MRI image in substantia nigra
BACKGROUND: In this study, we explored whether the proposed short-echo-time magnitude (setMag) image derived from quantitative susceptibility mapping (QSM) could resemble NM-MRI image in substantia nigra (SN), by quantitatively comparing the spatial similarity and diagnosis performances for Parkinso...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7325114/ https://www.ncbi.nlm.nih.gov/pubmed/32605601 http://dx.doi.org/10.1186/s12883-020-01828-8 |
Sumario: | BACKGROUND: In this study, we explored whether the proposed short-echo-time magnitude (setMag) image derived from quantitative susceptibility mapping (QSM) could resemble NM-MRI image in substantia nigra (SN), by quantitatively comparing the spatial similarity and diagnosis performances for Parkinson’s disease (PD). METHODS: QSM and NM-MRI were performed in 18 PD patients and 15 healthy controls (HCs). The setMag images were calculated using the short-echo-time magnitude images. Bilateral hyperintensity areas of SN (SN(hyper)) were manually segmented on setMag and NM-MRI images by two raters in a blinded manner. The inter-rater reliability was evaluated by the intraclass correlation coefficients (ICC) and the Dice similarity coefficient (DSC). Then the inter-modality (i.e. setMag and NM-MRI) spatial similarity was quantitatively assessed using DSC and volume of the consensual voxels identified by both of two raters. The performances of mean SN(hyper) volume for PD diagnosis on setMag and NM-MRI images were evaluated using receiver operating characteristic (ROC) analysis. RESULTS: The SN(hyper) segmented by two raters showed substantial to excellent inter-rater reliability for both setMag and NM-MRI images. The DSCs of SN(hyper) between setMag and NM-MRI images showed substantial to excellent voxel-wise overlap in HCs (0.80 ~ 0.83) and PD (0.73 ~ 0.76), and no significant difference was found between the SN(hyper) volumes of setMag and NM-MRI images in either HCs or PD (p > 0.05). The mean SN(hyper) volume was significantly decreased in PD patients in comparison with HCs on both setMag images (77.61 mm(3) vs 95.99 mm(3), p < 0.0001) and NM-MRI images (79.06 mm(3) vs 96.00 mm(3), p < 0.0001). Areas under the curve (AUCs) of mean SN(hyper) volume for PD diagnosis were 0.904 on setMag and 0.906 on NM-MRI images. No significant difference was found between the two curves (p = 0.96). CONCLUSIONS: SN(hyper) on setMag derived from QSM demonstrated substantial spatial overlap with that on NM-MRI and provided comparable PD diagnostic performance, providing a new QSM-based multi-contrast imaging strategy for future PD studies. |
---|